TRIANGULAR ECCENTRIC FOOTING

Поділитися
Вставка
  • Опубліковано 22 жов 2024

КОМЕНТАРІ • 54

  • @Inspirational_Homes
    @Inspirational_Homes 3 роки тому +3

    It would have been great if you explained what "extra bending moment" this footing resists i.e how does this triangular section resists the moment

  • @tejasvenom1952
    @tejasvenom1952 3 роки тому +1

    Hi sir... This video is really nice.. Same situation as in my case. Even I'm designing a G+2 Residential structure. Sir. Can you please tell me how to design for corner footings?

  • @kannikagowda2905
    @kannikagowda2905 3 роки тому +2

    Hi .. please make a video of complete design of an eccentric footing.

  • @IrfanShaikh-SE
    @IrfanShaikh-SE 3 роки тому

    Hello , How r u.
    Please make more videos like this in detail. I would be greatful if you make thess types of videos with detail explanation.

  • @khasabkhb736
    @khasabkhb736 3 дні тому

    Eccentric footing ka video banaye na sir kaise jali bandhte he eccentric footing beam BHI rahte hai kisi kisi me ek life video banaye pura details me eccentric footing ka

  • @manojkumar-qu8ml
    @manojkumar-qu8ml 3 роки тому

    May I know the how much load carrying capacity of footing decrease if beam or trapezoidal rcc not given

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 роки тому

    What are the forces on column.
    What is bearing capacity.
    Hiw is the pressure diagram.
    Why top steel is provided

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 4 роки тому +1

    Excellent video sir. Thnx a lot

  • @loksapps5455
    @loksapps5455 5 місяців тому

    How much depth required for G + 2 ?

  • @anandgor4181
    @anandgor4181 9 місяців тому

    Extra bending bar information which very useful

  • @gurvindersingh-if5te
    @gurvindersingh-if5te 3 роки тому

    Sir
    Please explain its design calculation how it will safe

  • @rudreshkamat1941
    @rudreshkamat1941 3 роки тому

    Can you share the design procedure, also pmax pmin .

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 роки тому

    Good.

  • @taysonwar8680
    @taysonwar8680 3 роки тому

    It's economical and money saving

  • @frsaj7396
    @frsaj7396 4 роки тому +1

    please shear with us how u calculate extra inclined bar height.
    another ques. u calculate footing two steps like 1st 600 mm and 2nd one 1075 mm. ples give me details

    • @civilstructuralengineering9272
      @civilstructuralengineering9272  4 роки тому +2

      hello, my RCC size along shorter span is 1675 mm from which I deduct depth of footing i.e. 600 mm so effective length = 1075 mm. & slope taken is 1:1 , so vertical height also 1075 mm

    • @frsaj7396
      @frsaj7396 4 роки тому +1

      @@civilstructuralengineering9272 if i take more or less than depth of footing its will be ok or not. please ans. me

    • @civilstructuralengineering9272
      @civilstructuralengineering9272  4 роки тому

      @@frsaj7396 no, it should be as described

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 роки тому

    Please show the behaviiur of footing along with column.

  • @gurvindersingh-if5te
    @gurvindersingh-if5te 4 роки тому

    Dear
    How in this footing uniform gross pressure occur or how gross pressure is less than safe bearing capacity of soil.if it does not certified this createria therotical it will settle so please explain it

  • @ganeshkale5900
    @ganeshkale5900 3 роки тому

    👍👍👍Please explain two way eccentric with reinforce and concrete details

  • @MohammadIrfan-jd3pk
    @MohammadIrfan-jd3pk 4 роки тому +1

    What is the load on column for which this footing was designed?

  • @jadhavajay15
    @jadhavajay15 4 роки тому +1

    Plz shear Excel sheet design or what method u used

  • @surajsurvase8519
    @surajsurvase8519 4 роки тому +1

    Aapka colum horizontal hai
    Jab column vertical aayga to ecentric footing kaisi aayegi

    • @civilstructuralengineering9272
      @civilstructuralengineering9272  4 роки тому +1

      Basic principle is same.We have to provide reinforcement to resist moment. Plz give us your mail ID, we will send details of vertical column eccentric footing.

    • @infanaik9892
      @infanaik9892 4 роки тому

      @@civilstructuralengineering9272 sir please send me also my mail id is ashutoshmnaik@gmail.com

  • @APBEngr
    @APBEngr 4 роки тому +1

    How to design this kind of footing?

  • @jaihind32949
    @jaihind32949 4 роки тому

    Very nice information.
    Thanks a lot

  • @umashankarsingh1248
    @umashankarsingh1248 3 роки тому

    Please load this video with translate into the Hindi language. Thanks