Why Single Core Cable Comes with AL Armoured not with Steel?

Поділитися
Вставка
  • Опубліковано 8 вер 2024
  • Why Single Core Cable Comes with AL Armoured not with Steel?
    Single core cables in conduction alternating current, can form annular magnetic field around the cable, steel belt or bare wire will form a closed loop path, forming eddy current, and eddy current will cause the cable heating, increase the loss of the cable.
    Three - core cables pass through the three-phase alternating current, the sum of the three-phase current is zero, so no eddy is produced in the guide ring of the guide steel belt and naked steel wire, so the steel armor can be steel.
    Need of special note is, single core cable is not can't armor, but is a magnetic strip or steel wire, often using the magnetic stainless steel belt and the permeability of stainless steel wire armoured can also be (single core cable used by stainless steel sheathed).
    In addition, magnetic steel wire is not cannot be used for single core cable armoring, but will have to cover (extruded) insulation wire, then squeeze insulated wire for cable armoring, insulation will ring magnetic circuit for segmentation, can't form a circular vortex, is also no problem.
    #cables #cable #neutral #Current #neutralcurrent #Unblancedsystem
    Solar
    Safest
    Smarter
    Saur urja
    Biljli Kaise bachaye
    Solar se Bijli Kaise Bachaye
    Benefits of Installing solar
    Profitable solar
    Solar k Fayede
    Solar Lagane k Fayade
    MCB
    MCCB
    ACB
    AJB
    ACDB
    DCDB
    Lighting Arrester
    walkway
    cable Tray
    Solar Panel
    Solar Inverter
    Solar Cable
    AC Cable
    Follow me on -
    Telegram- t.me/+uVOzUWjD...
    LinkedIn- / raman-kumar-666436141
    Facebook - / solarfacts-37057195372...
    solar structures
    Solar panel mounting structure
    Solar mounting structure
    acdb and dcdb for solar system
    acdb box price
    dcdb box for solar system
    dcdb box price
    long rail solar structure
    mini rail for solar panels
    mini rail solar structure
    solar mounting structures
    solar panel structure
    solar structure
    solar structure types
    types of mounting structures for solar panels
    types of solar mounting structure
    types of solar structure
    mounting structure for solar panels
    mono rail solar structure
    solar acdb box
    solar acdb dcdb box
    solar dcdb box
    solar mini rail
    standing seam solar structure
    tilted solar structure
    acdb box for solar
    dcdb box for solar
    Video link -
    1. How solar zero export works.- lnkd.in/evPgfuj2
    2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
    3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
    4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
    5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
    6. How to check Current Transformers? - lnkd.in/eT5gc99e
    7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
    8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
    9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
    10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
    11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
    12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
    13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
    14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
    15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
    16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
    17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
    • Solar Power Plant Shad...
    18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
    19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
    20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
    21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
    22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
    For more information contact us 😊.
    Name - Raman Kumar
    Contact No- 9871073342

КОМЕНТАРІ • 23

  • @satyaprasadtripathy8164
    @satyaprasadtripathy8164 11 місяців тому +1

    recently i came across your channel and found it as a treasure of knowledge for those who are in renewable sector..watching all your videos one by one ..Thank you so much for sharing knowledge with us..Please keep making such videos..

  • @manojdevarakonda3047
    @manojdevarakonda3047 11 днів тому

    Good expanation

  • @sumits_shetty
    @sumits_shetty Місяць тому

    Awesome 👍

  • @pradeeppoojari2786
    @pradeeppoojari2786 7 місяців тому

    hello Man , 2 core cables in AC system always steel wire Armor , where as 1 core cable in AC system with Aluminium Armor...since there is no return path in 1 core cable hence heating effect due to steel. To avioid this AL Armor is used

  • @PratinChaudhari
    @PratinChaudhari 2 роки тому +2

    Plz make a video on cable design for solar plants 🙏

  • @neutral6778
    @neutral6778 2 роки тому +1

    Very helpful sir

  • @GauravKumar-bb3ts
    @GauravKumar-bb3ts Рік тому

    Sir phase to phase megnetic field cut ho jata hai toh induction motor kesa work karega is condition Mai

  • @RajeshVerma-cx9bx
    @RajeshVerma-cx9bx 2 роки тому +1

    Can you tell about circulating current in single core cable and three core MV cable and also confirm about grounding of terminal and joints in both type of cable

  • @khanimran6313
    @khanimran6313 Рік тому +1

    When load will be unablanced

    • @solarfacts4242
      @solarfacts4242  11 місяців тому

      There is no problem it is single phase

  • @sagarbose1679
    @sagarbose1679 2 роки тому +1

    There is a four core armoured cable laid underground from Transformer to LT Panel at my place for a three phase connection to the commercial setup on the ground floor and a three phase meter is also installed. Now I want to get another single phase meter connection installed for my residence on 1 st floor from the same LT PANEL. Is it possible to draw such another supply for single phase meter from one of the three phases that are already providing three phase supply through same LT Panel for my commercial connection on the ground floor? Or I have to lay another two core armoured cable from Transformer to connect to the new single phase meter I am planning to install now ?

    • @solarfacts4242
      @solarfacts4242  2 роки тому

      No you can use single phase from your existing 3 phase meter

  • @pradeeppoojari2786
    @pradeeppoojari2786 7 місяців тому

    you should say 1 core instead of single phase

  • @Amazingsolar7753
    @Amazingsolar7753 2 роки тому +1

    👍👍👍☀️☀️👍👍

  • @GauravKumar-bb3ts
    @GauravKumar-bb3ts Рік тому

    Sir phase to phase megnetic field cut ho jata hai toh induction motor kesa work karega is condition Mai

  • @GauravKumar-bb3ts
    @GauravKumar-bb3ts Рік тому

    Sir phase to phase megnetic field cut ho jata hai toh induction motor kesa work karega is condition Mai