Introducing MRI: The Gradient Echo Pulse Sequence and Modified Flip Angle (34 of 56)

Поділитися
Вставка
  • Опубліковано 27 вер 2024
  • www.einstein.yu... - The thirty-fourth chapter of Dr. Michael Lipton's MRI course covers The Gradient Echo Pulse Sequence and Modified Flip Angle. Dr. Lipton is associate professor radiology at Albert Einstein College of Medicine and associate director of its Gruss Magnetic Resonance Research Center.

КОМЕНТАРІ • 27

  • @srikrishnandivakaran891
    @srikrishnandivakaran891 2 роки тому +2

    Enormously invaluable set of video lectures. Even as a theoretical computer scientist these lectures are accesible, very crisp and are carefully planned to provide key insights coupled with excellent illustrations.
    I cannot thank Dr. Lipton enough and also a teacher his lectures are a benchmark for combining concepts with illustration of these concepts. This resource is helping me in my attempt to develop efficient algorithms for registering MRI scans of patients (i.e. like the keyhole technique many fast algorithms can be developed by restricting the field of view and augmenting this with past MRI scans).

  • @trnr2000
    @trnr2000 2 роки тому +9

    Every time I'm teaching MRI physics, I'm rewatching your lectures. Thank you for helping to make MRI more clear. Your lectures are still being watched :)

  • @ak49gun123
    @ak49gun123 6 років тому +3

    The best MRI lecture

  • @eglen7664
    @eglen7664 6 років тому +1

    Dr. Lipton you are my hero

  • @dangerousman4071
    @dangerousman4071 2 роки тому +1

    could you make a video on spoiled and coherent GRE sequences. Just a little bit of detail on GRE subtypes would be the best.

  • @shashwatpriyadarshi972
    @shashwatpriyadarshi972 4 роки тому +1

    Why do we need the dephasing pulse ,anyways protons were dephasing via T2*decay?what is that rephasing lobe during slice selection?

  • @mikeb2407
    @mikeb2407 2 місяці тому

    Can someone explain how the amount of longitudinal recovery impacts the amount of transverse magnetization you can generate? I thought the magnet only measures transverse magnetization from phase coherence due to T2 processes?

  • @chinmoy11091987
    @chinmoy11091987 5 років тому +1

    Thank you for sharing this great lecture with all

  • @share21gaming95
    @share21gaming95 3 роки тому

    Just want to know whether the last series of images are proton density weighted images?

  • @rajaestiha2211
    @rajaestiha2211 5 років тому +1

    thanks very very much , you are the best doctor !

  • @shashwatpriyadarshi972
    @shashwatpriyadarshi972 4 роки тому

    When you apply the RF pulse when the hydrogen nucleus has not regained its longitudinal magnetization fully then don't you cause partial saturation of hydrogen nucleus that is doesn't it go beyond 90?

  • @ashleygesty7671
    @ashleygesty7671 8 років тому

    thanks very much sir this was very helpful!

  • @timurnavruzov7145
    @timurnavruzov7145 8 років тому

    Thank you very much

  • @TheDschn001
    @TheDschn001 8 років тому

    Thanks you!

  • @jay_carraway
    @jay_carraway 7 років тому +3

    Smart professor, not so smart/quick students. Some of their questions really made me wonder if they were listening at all... Dr. Lipton really explains it coherently and clear. Thank you for that!

    • @shashwatpriyadarshi972
      @shashwatpriyadarshi972 4 роки тому +7

      Bro, probably you are very intelligent because even I had to pause multiple times hear it over again to get hold of this complex topic.By the way I am a radiologist in India ,what about you?

    • @TC-dw6wg
      @TC-dw6wg Рік тому

      He probably works in the field as a licensed MRI tech and this is basic knowledge to any decent MRI tech. Low self esteem statement made by Jay as he needs to build himself up by putting others down. Sad

    • @jay_carraway
      @jay_carraway Рік тому

      @@TC-dw6wg Nope, that was five years ago while doing my physics degree at university :D Am now working in software development. Sorry, that was really the way I felt watching the video.

  • @shashwatpriyadarshi972
    @shashwatpriyadarshi972 4 роки тому

    Does loss of transverse magnetization and regrowth of longitudinal magnetization of a hydrogen nucleus occur simultaneously?

  • @rudhajassim9469
    @rudhajassim9469 2 роки тому

    thank you great explanation

  • @Aj_For6
    @Aj_For6 2 роки тому

    @13:31 - when transverse signal is less, does the parameters of RF pulse lessen to get same degree of 45 angle?

    • @TC-dw6wg
      @TC-dw6wg Рік тому

      Yes. You either shorten the duration or strength of the signal to achieve the lower flip angle. Ex. 45 deg.

  • @anwar87999
    @anwar87999 7 років тому

    Great lectures, thanks aren't enough

  • @fardinrahman1145
    @fardinrahman1145 3 роки тому +1

    ewwww

  • @fardinrahman1145
    @fardinrahman1145 3 роки тому +1

    a jew