Paano mag D.I.Y. sa pagkabit ng RCBO Circuit Breaker

Поділитися
Вставка
  • Опубліковано 18 жов 2024

КОМЕНТАРІ • 141

  • @KaFisios143
    @KaFisios143 2 роки тому +1

    Tamslab idol pang 199 watching here galing mo idol all rounder pag dating sa master of trade thanks for sharing watching from Nz

  • @mercyvlogs498
    @mercyvlogs498 2 роки тому +1

    Wow ang galing all around yung work mo sir. Skilled talaga siya. Good job and keep sharing and keep vlogging your knowledge as a constructor mercy here

  • @eyahsmixvlog4569
    @eyahsmixvlog4569 2 роки тому

    Watching here host, amazed ako sa views mo host congrats

  • @ninesiblingschannel9149
    @ninesiblingschannel9149 Рік тому

    Another wonderful and very informative video po Sir Rolly 😊

  • @JOY_PELIGRINO
    @JOY_PELIGRINO Рік тому

    Goodmorning Sir Rolly ! Thank you for sharing another informative video Sir...watching now po 😊

  • @juantaman1517
    @juantaman1517 7 місяців тому

    Ayos sir ahhh.. Mcb ang main tapos rcbo ang sub breakers.. Laki gasto nito sir hehe lalo mahal ang rcbo

  • @degeecuda
    @degeecuda 3 роки тому +1

    Watching here na sa mga dati mong video. Tapos ko na mapanood mga latest upload mo my friend.

  • @dens0616
    @dens0616 Рік тому +3

    Pwede nman sir n hnd mo n putulan ung bar mo, ung taas n ng mcb ung gawin mong load side. At sna po nilagyan mo ng grounding para nman mapakinabangan mo ung full specs ng rcbo.

    • @rollyyangtv658
      @rollyyangtv658  Рік тому +1

      Thanks sa info sir dati na KC Ang naka install Ang wiring nya sir Hindi na kaya lagyan at kung lalagyan panibagong linya subrang abala at maraming sisirain

  • @AndzLoraine
    @AndzLoraine 29 днів тому

    Galing mo naman bos

  • @manlalapas
    @manlalapas 2 роки тому

    Saludo sir. Humble. Sir sa future mo na installation ng wire sir gamit po kayo ng Color coding (Base on PEC - Philippine Electrical Code) sir para madaling sundan nang ibang electrical technician pag iba na gumawa. yan lang po. keep the good work po sir.

  • @junpaoner9257
    @junpaoner9257 Рік тому

    Master saludo ako sayo.

  • @Ixusandy007
    @Ixusandy007 10 місяців тому +1

    may suggestion po ako,hindi na po ninyo kailangan ng jumper from mcb to rcb,yong galing service entrance ang tapping ay sa baba o bottom ng mcb at ang bus bar bridging ay hindi na kailangan putulan sapagkat nka design na po yon sa 9 branches kasama main mcb, mula top portion ng mcb going sa destribution ng rcb salamat po

  • @tanloctt6855
    @tanloctt6855 3 роки тому +1

    My dear friend MaşAllah nice

  • @babitchannel2465
    @babitchannel2465 Рік тому

    Watching here idol from KFC

  • @flappymojako7609
    @flappymojako7609 Рік тому

    3 wire system(line to line + ground) pala sir ang utility supply dapat may individual grounding wire sa bawat device para gumana ang earth keakage ng RCBO na ikinabit mo . kung 2 wire system (line to ground) naman ok na sana yan ..advise ko lang sir sa electrical wire dressing (EXTRA WIRE LOOPING ) po sana palagi

  • @kuyaemantv
    @kuyaemantv Рік тому

    malikot master videographer mo hehehe ingat po master

  • @elisaclaeys2720
    @elisaclaeys2720 Рік тому

    Good job sir

  • @reyyanez6705
    @reyyanez6705 3 роки тому +5

    MCB, RCBO, RCCB or RCD have different characteristic in terms of functional aspects. The reason bakit kailangan ng MCB instead of RCBO sa incoming power source mo kasi po, redundant na Ang scheme of protection nyo dahil meron ka na sa branch circuit. At kailangan mo ng MAIN ISOLATION POINT sa incoming power source, basically separately isolation point yung load side at incoming power source side.

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому +1

      Thanks sir sa explanation

    • @reyyanez6705
      @reyyanez6705 3 роки тому +1

      @@rollyyangtv658 sharing thoughts in electrical aspect, makes better electrical safety to electrical practitioner.

    • @wcano
      @wcano 2 роки тому +4

      Masyadong Sensitive na ang RCBO pag ginamit para maging main baka laging mag trip. Mawawalan din ng power lahat ng branches.

    • @rodeelaglipay8953
      @rodeelaglipay8953 Рік тому

      Ung bagong labas na rcbo kompletos na .

    • @fecarumay5076
      @fecarumay5076 Рік тому +3

      kylngan ilagay mo yun ground wire sa mga load branch useles ang ground protection ng rcbo mo hindi gagana ang prection nya sa ground sayang lang.

  • @jomariewabina9558
    @jomariewabina9558 2 роки тому

    safe na safe Yan paps ahh ganda

  • @justlearnhow4136
    @justlearnhow4136 8 місяців тому

    Tanong lang po, ubra paba ang RCBO kung wala anamang ground yung mga wirings sa bahay??
    Newbie lang po ako

    • @rollyyangtv658
      @rollyyangtv658  8 місяців тому

      Kung yang kinabit namin na Yan sir yes KC sinubukan ko binasa Ng tubig gumana naman cya kaya lang Hindi nalagyan Ng ground Yan KC dati Ng wiring Yan Hindi na malagyan maliban kung palitan lahat

  • @ms.winwyn3260
    @ms.winwyn3260 3 роки тому +1

    Good am po ask lang d ba dapat pag line to linerequired Ang ground KC parehong may daloy Ng kuryente Yan. Do pd ka makuryent pag nag maintenance ka . D ba.

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Hindi Naman po KC Ang kaylangan lang lagyan ay Ang appliances na may ground gaya ng ref at itong nilagyan ko is dati ng may linya sir townhomes KC ito Bali pinalitan ko lang ng breakers salamat sa pagtanong sir👍👍👍

    • @ms.winwyn3260
      @ms.winwyn3260 3 роки тому +1

      Ganun PO ba eh Kung nakagroung Naman Ang meterbase ok Yun. Dahil line to line nga dapat na meron d porket may spo lang . Salamat.

    • @boybravo689
      @boybravo689 3 роки тому +1

      @@rollyyangtv658 boss line to line at line to neutral dapat may grounding conductor sir paano makakadetect ng ground fault at unbalanced load yang rcbo mo kng walang grounding conductor sir

  • @5884genesis
    @5884genesis 2 роки тому +1

    sir dapat sa ilalim mo dinaan ang source ng main ng mcb para dna kailngan putulan ang bus bar.. baliktaran kasi yang mcb sir..

    • @gemreemangilit7786
      @gemreemangilit7786 2 роки тому

      Correct po since yung MCB po gamit nya is reversible and sa baba yung load side ng mga RCBOs. So pwedeng i busbar from MCB to RCBO sa taas.

  • @normanomli8703
    @normanomli8703 2 роки тому +1

    sir mag trip pa rin ba ung mga RCBO pag nag karoon ng ground fault kahit di mo kinabit ung ground(white wire) connection sir?

    • @rollyyangtv658
      @rollyyangtv658  2 роки тому +1

      Yes sir sensitive cya sa ground fault kahit wala kaya Hindi nakakabit KC dati na KC wiring pero nagana parin Ang ground fault

  • @maynardagustin1674
    @maynardagustin1674 2 роки тому +1

    Sir nakikabit ako electric sa kaibigan ko line to neutral. Pero live lng ang ginapang papunta s bahay ung neutral dinikit lng sa bakal safe ba yun?

    • @rollyyangtv658
      @rollyyangtv658  2 роки тому

      Mali po un dapat kasabay parin nya ung ground na kasakama ng live galing sa electric provider po sa Lugar nyo tapos magbaon pa kayo ng grounding rad at nakakabit din doon sa ground na un sir

  • @RobertoGuanzon-t2o
    @RobertoGuanzon-t2o 7 місяців тому

    Sir 30amp ung main ko pwd ba ako mag dagdag ng dalawang 20amp at 15 amp isa pang 20amp sa aircon

    • @rollyyangtv658
      @rollyyangtv658  7 місяців тому

      Mas maganda palitan mo ng 40amp main mo sir kung dalawang 20amp at isang 15 kc gamit mo sa aircon ung dalawang 20amp

  • @pedroacostajr.6013
    @pedroacostajr.6013 Рік тому

    bos pwd po ba sa TaaS n lang dumaan lahat ng suply ng kuryinte

  • @ezmaxhernandez8611
    @ezmaxhernandez8611 3 роки тому +1

    Sir yun po ba rcbo na ginamit ninyo ay 1P+N? Thank you.

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому +1

      Yes sir rcbo 1p+n pero main na nilagay ko rcb sensitive KC rcbo Naman Ang branches kaya mcb nilagay ko main

    • @cgbusa0229
      @cgbusa0229 2 роки тому

      Bali ilang branch circuit breakers po iyan at ilan lahat ang total na ampheres?

  • @JVB79
    @JVB79 2 роки тому +1

    ❤️Thank You For Sharing&Support ..., Bless Us All... 💞💞💞fr my sisters🎋"GARDENING HOUSE PLANTS" "MOMMY BHERN" & "Thelovetitaheart TV" 🙏😇.

  • @danilogo235
    @danilogo235 2 роки тому +1

    Sir bkit ka pa nag jumper sa main. Pwede nman po ung main wire na galing sa load side ng meter ay dapat sa load side ng main breaker mo nilagay. Tapos ung busbar sa ibabaw ng line side ng main breaker. Salamat Po...

    • @theftofficial780
      @theftofficial780 Рік тому

      opo master ,. eto. diin iniisip ko kanina hehe pero good job parin❤

  • @rolandobalanza
    @rolandobalanza 2 роки тому

    Sir.pwede po ba gamiting breaker ng ref ang rcbo 20 amps..

  • @ronnieberba6611
    @ronnieberba6611 Рік тому

    Bro nakausli yung flexible mo masagwa tingan sa loob ng board mo

  • @ydnararutnev1434
    @ydnararutnev1434 2 роки тому

    idol paset nmn ng cb, qng anung mainbreaker ang puede s 1 ref, 1aircon 6outlet at ilaw, mga ilng cb ang ing amp ang puede, slamat

    • @rollyyangtv658
      @rollyyangtv658  2 роки тому +1

      Pm ka nalang sa messenger ROLLY YANG same profile picture

  • @rodeelaglipay8953
    @rodeelaglipay8953 Рік тому

    Line to line ba ung pag install m boss

  • @pedroacostajr.6013
    @pedroacostajr.6013 Рік тому

    boss tanung lang po ako..pwd m b ung 12 n butas sa bahay chint panel board.

  • @vioconstructionservices6218
    @vioconstructionservices6218 3 роки тому +1

    Okey ah

  • @francispatio4512
    @francispatio4512 3 роки тому +1

    -yung mcb ba sir, hindi ba yan reversable sir?

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Hindi sir

    • @reyyanez6705
      @reyyanez6705 3 роки тому +1

      Yung bagong install na MCB ay reversible, pero lagi tandaan kung Ang tamang orientation ng switch positions at incoming cable/ wire galing metro.

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому +1

      @@reyyanez6705 salamat sa idea sir

    • @francispatio4512
      @francispatio4512 2 роки тому

      -kumusta yung busbar mu sir ok nmn b hangang Ngayon sir?

  • @namikazeminato4798
    @namikazeminato4798 Рік тому

    Tanong ko lang sir pede ba RCBO sa window type aircon

  • @ragedsonyang9772
    @ragedsonyang9772 2 роки тому

    Sir ano ginamit mong Main breaker

  • @jessicafuentes1192
    @jessicafuentes1192 2 роки тому

    ser anong brand ng breaker nyan

  • @juancarlossandoval5628
    @juancarlossandoval5628 Рік тому

    Anu po size ng pambutas ng panel ?

  • @jcelvadolauta8274
    @jcelvadolauta8274 2 роки тому

    Bkit mcb ung main mo,tapos rcbo ung branches..?

    • @rollyyangtv658
      @rollyyangtv658  2 роки тому

      KC sir rcbo sensitive na masyado kung kaya mcb na ninagay ko sa main nya may Isang comment Jan naipaliwanag kung bakit mcb nilagay ko at hindi pa Ako professional DIY lang Yan sir kaya nagpapaturo pa nga Ako kita Naman sa video salamat po

    • @gemreemangilit7786
      @gemreemangilit7786 2 роки тому +1

      Hindi po. Tama naman po sya sa part na yun. Hindi po advisable na RCBO ang main dahil po sensitive sya at lahat ng branch ay damay just in case any sa branch ay magtrip. Patay po ilaw sa lahat ng parts ng bahay. Di rin po advisable na RCCB ang gawing main CB dahil wala po itong overload protection just in case magoverload po. MCB po talaga dapat ang main.

  • @burhantico9865
    @burhantico9865 2 роки тому

    Boss ano po pangalan nilagay mo sa taas busbar b iyan?

  • @paanovlog3296
    @paanovlog3296 2 роки тому

    sir paano po naman magkabit ng ganyan sa line to neutral ?pwde ba gamitin ang 1p+N?

  • @anyeonghusky7981
    @anyeonghusky7981 6 місяців тому

    Kung di aq ngkakamali reversible MCB ang main breaker n ginamit mo, na dpat sa ilalim n lang pinadaan ang main supply, pra dina pinutol busbar....

  • @boitigas6547
    @boitigas6547 2 роки тому

    parang redundant namn ung mga nilagay na mga breaker ni boss, di po ba dapat RCBO at ung mga sub ay RCCB at MCB correct me if im wrong

    • @gemreemangilit7786
      @gemreemangilit7786 2 роки тому

      Hindi po. Tama naman po sya sa part na yun. Hindi po advisable na RCBO ang main dahil po sensitive sya at lahat ng branch ay damay just in case any sa branch ay magtrip. Patay po ilaw sa lahat ng parts ng bahay. Di rin po advisable na RCCB ang gawing main CB dahil wala po itong overload protection just in case magoverload po.

  • @anamaepanilag4802
    @anamaepanilag4802 2 роки тому

    kasya ba sa mcb yung rcbo na breaker

  • @boybravo689
    @boybravo689 3 роки тому +1

    Boss bakit di ka naglagay ng grounding conductor kailangan yan para madetect ng rcbo yong ground fault

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Hindi na maisuksuk bro KC dati ng install Bali breaker lang pinalitan

    • @boybravo689
      @boybravo689 3 роки тому +2

      @@rollyyangtv658 bro sayang yong characteristic ng rcbo hindi magpafunction yong ibang protection kng walang grounding conductor bro

    • @yolandocarreon5377
      @yolandocarreon5377 2 роки тому

      @@boybravo689 wow boy, punyeta ka marunong ka pala a bilib ako sa imo ha.

  • @albertoaquino8717
    @albertoaquino8717 3 роки тому +1

    All around kamet gayam LAKAY BANGIS FOREMAN KAPAY

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Wen lakay agyaman nak ta supportam kabagis🙏

  • @merlitoavila9318
    @merlitoavila9318 Рік тому

    mas ok at complete ang function ng rcbo kung may mga equipment ground po yan. hindi rin po kasi mag ti trip ang RCBO kapag nalagyan ng tubig ang mga CO or LO at ewan kolang rin po kung effective sya kapag may leakage ang mga line nyo po. for me mas maganda po if nag lagay narin kayo ng equipmemt ground

  • @mcnod32
    @mcnod32 2 роки тому

    mas malinis sana kung nilagyan ng coupling ang panel board para sa flexible para magandang tingnan at dapat observed na din ang proper grooming ng mga wire.

  • @fernandobautista7089
    @fernandobautista7089 2 роки тому

    Mataas po yata yong set up ng distribution box

  • @ranatoilagan7382
    @ranatoilagan7382 2 роки тому

    Sir magkano po ang ganyang complet breaker at panel bord.

  • @olivergrospe3348
    @olivergrospe3348 3 роки тому +1

    Sir baka may link ka po mg binilhan mo ng rcbo sa lazada, thank you in advance

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому +1

      Sir sumret pH shopee RCBO Circuit Breaker Jan ka tumingin

    • @olivergrospe3348
      @olivergrospe3348 3 роки тому +1

      @@rollyyangtv658 sir salamat po ng marami

  • @pauldalton7182
    @pauldalton7182 3 роки тому +1

    Comments ko lang yg mga flexible conduit pipe dapat my mga fittings both end sa boxes @ panel board gumamit ka ren ng standard na color coding black L1 white L2 or neutral green, Y w/G stripe, stranded ang wire mo gumamit ka ng pointed lugs or both less connector

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Salamat po sa tips kaya lang po LAHAT black KC dati na nakalagay Hindi narin KC kaya palitan🙏🙏

    • @yolandocarreon5377
      @yolandocarreon5377 2 роки тому

      @@rollyyangtv658 sir totoo yan lalo hindi nman ikaw nauna nyan o khit nauna ka para yung magtrouble shoot ay malalaman kung skilled hehehehe.

  • @rednaxxander5067
    @rednaxxander5067 2 роки тому

    Bakit no. 5.0 ang gamit mo na main wire

  • @romycastillo8413
    @romycastillo8413 2 роки тому

    Like

  • @Ixusandy007
    @Ixusandy007 10 місяців тому

    naputol po comment ko nka design sa 9 branches at maari mag dagdag para sa additional circuit salamat muli

  • @shigayamato4236
    @shigayamato4236 2 роки тому

    may napansin lang ako sa way ng pagbalot mo po ng electrical tape parang di mo po tinupi yung dulo

  • @gilbarqueros2496
    @gilbarqueros2496 Місяць тому

    Nag sisiguro lng sya ma baka hindi reversible ang mcb kaya nag jumper sya

  • @efrenmiguel9716
    @efrenmiguel9716 Рік тому

    hindi po magagamit ng rcbo sa mga protective uses nya if walang ground. mawawalang say say ang pagka Rcbo nya.

    • @EdgardoFernandez-t6d
      @EdgardoFernandez-t6d 10 місяців тому

      Boss need ba lhat ng gagamitin eh puro rcbo, for protection Baga. Thank you

  • @barztv1392
    @barztv1392 3 роки тому

    Sir anong tawag sa distribution box na pwedeng ibaon sa semento
    Maraming salamat sir

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Sir metal or PVC Panel pwd ibaon sa cement RCBO rccb at mcb pwd ikabit sa magkakaibang brand ng panel boar

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Miniature circuit breaker metal or PVC Panel board sir Ang bilhin mo kahit among brand pwd

    • @bigmore8734
      @bigmore8734 3 роки тому +1

      BARZ TV Flush mounted po sa pagka alam ko, corrrect me if I'm wrong.

    • @gemreemangilit7786
      @gemreemangilit7786 2 роки тому

      Flush mount po yung nababaon while Surface Type po yung no need ibaon sa pader at screw lang sa wall.

  • @barrera021986
    @barrera021986 2 роки тому

    ano pong brand ng rcbo nyo

  • @namikazeminato4798
    @namikazeminato4798 2 роки тому

    Sir line to line po ba kau or line to neutral pede po ba gamitin yan line to line

    • @rollyyangtv658
      @rollyyangtv658  2 роки тому +1

      Line to line ito po ito Kaya kung line to line kayo pwd po

    • @namikazeminato4798
      @namikazeminato4798 2 роки тому

      @@rollyyangtv658 thanks sir sana umabot kau 10mil subs

    • @namikazeminato4798
      @namikazeminato4798 2 роки тому

      Last n lng po na tanong ano pong normal na ampere kadlasan ginagamit sa main breaker di ma kasi mabasa diko na alam kung ilang ampere na nakakabit

    • @namikazeminato4798
      @namikazeminato4798 2 роки тому

      I mean fuse

    • @rollyyangtv658
      @rollyyangtv658  2 роки тому

      @@namikazeminato4798 sir nakadepende sa gamit un pero madalas na nilalagay sa main ay 40amp or 60 amp

  • @talpolano4549
    @talpolano4549 Рік тому

    Kng wlang ground may feature Ang rcbo na Hindi gagana :)

  • @master_0323
    @master_0323 3 роки тому +1

    Dapat mcb gnamit mo sa mga outlet kc wala namang protection ang rcb sa overlod

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому

      Salamat sir sa tip mo next time

    • @reeblaagan7310
      @reeblaagan7310 3 роки тому +1

      @@rollyyangtv658 Meron naman yata protection sa overload ang RCBO sir.

    • @rollyyangtv658
      @rollyyangtv658  3 роки тому +1

      @@reeblaagan7310 yes sir meron protection sa overload Ang rcbo

    • @gemreemangilit7786
      @gemreemangilit7786 2 роки тому

      Meron pong protection ang RCBO sa overload kaya po Residual Circuit Breaker with Overload protection po tawag sa kanya. RCCB po ang wala pong overload protection at need ng partner na MCB for overload protection.

    • @orlydacuyanan8848
      @orlydacuyanan8848 Рік тому

      Ang alam q ang pinagkaiba lang ng rcbo at rccb ung shortcircuit sa overload parehas slang meron..

  • @MrSanjaykpatil
    @MrSanjaykpatil 11 місяців тому

    What is this language.....

  • @rednaxxander5067
    @rednaxxander5067 2 роки тому

    May mali, wala kang suot na working gloves at hard hat,. 😂

  • @dannyg5095
    @dannyg5095 28 днів тому

    Maliit ang main wire mo para sa 63 ampere, dapat number #6 na wire ginamit mo