Solar Plant LA selection Lightning Arrestor

Поділитися
Вставка
  • Опубліковано 6 вер 2024
  • #solarLA #lightiningarrestor
    Hi, If you are targeting Solar Industry jobs in Dubai , then this might be "SUPER helpful"
    Learn all About Solar Plant DATA analytics & advance report creation:
    www.udemy.com/...
    Digital CV creation for Dubai JOBS on Solar PV Industry:
    www.udemy.com/...
    𝙁𝙍𝙀𝙀 𝘿𝙤𝙬𝙣𝙡𝙤𝙖𝙙 𝙁𝙞𝙡𝙚 or APP 𝙄𝙣𝙨𝙩𝙧𝙪𝙘𝙩𝙞𝙤𝙣𝙨:-
    𝙎𝙩𝙚𝙥 1:- connect with me on Linkdln or Instagram from below link.
    Linkdln:bit.ly/3xG9tQX
    Instagram:bit.ly/3jLSV5e
    𝙎𝙩𝙚𝙥 2:- share the video in a technical group or post on Linkdln ,watsapp or telegram.
    𝙎𝙩𝙚𝙥 3:- Take a screen shot & message Me either on Linkdln or Instagram with a screenshot attached that you have shared the file I will share you the FILE link to download.
    For Questions/Technical support connect with me.
    Subscribe:bit.ly/2XoCPH8
    Linkdln:bit.ly/3xG9tQX
    Instagram:bit.ly/3jLSV5e
    Facebook:cutt.ly/JQDl7Ba
    Quora:bit.ly/3iFvM4X
    Telegram Solar Group:bit.ly/3iFC2d9
    Twitter:bit.ly/3iEYdQw
    IMPORTANT Solar Videos
    SOLAR DC cable MEGGER TEST - • SOLAR DC cable Insulat...
    Solar DC Cable management - • Solar DC cable Managem...
    1500VDC Solar Plant - • 3MW Solar Central Inve...
    Solar Plant Thermography - • solar plant thermography
    Wrong PR%😭 What to do?? - • Solar PR% issue | Sens...
    Solar Plant SECRET - • Solar Plant SECRET , ...
    Tilt 📐/ Orientation📈 without PvSyst - • Tilt / Orientation wit...
    Solar☀️ Plant 🔺 Thermography❗ - • solar plant thermography
    Solar 100kw Plant , perfect installation - • 100KW Solar Plant | in...
    Solar Plant power Factor🚫- • Solar Plant | Power Fa...
    Solar Plant Specific Yield ?? - • Solar Specific Yield ?...
    Solar Plant AC/DC earthing ? Why - • Solar Plant Earthing |...
    Solar 🌞Net Meter Fault Solution - • Net metering Import v...
    Solar 🌞 PID LOSS 📉♻️- • PID loss in SOLAR Pane...
    Solar Plant Measurements - • Solar Plant Measuremen...
    Solar Plant 🌞Ground Fault - • Solar Plant Ground Fau...
    Solar Inverter Derating 🔥- • Solar inverter Deratin...
    Solar Plant Overheating Issue🔥- • Solar Plant Over heati...
    Solar Eclipse 🌞🌜Genration Analysis - • Solar Eclipse Genratio...
    Free Pvsyst software Book ♻️- • Free PvSyst Documents ...
    Solar Plant money Payback Calculation 💵- • Solar Plant Money Retu...
    Solar🌞 plant LA earthing Calculation in हिंदी में♻️- • Solar Plant LA selecti...
    Types of Solar🌞 cell Fault👨🏻‍🔧 हिंदी में - • Types of Defects in So...
    Solar🌞 inverter Selection calculation👨🏻‍🔧 हिंदी में - • Solar Inverter Selecti...
    Solar 👨🏻‍🔧Parking 🚕Installation 👨🏻‍🔧 हिंदी में - • Solar Parking | Cost |...
    Solar tilt angle & Azimuth experiment🔅- • Video
    Middle East Energy expo🔅♻️- • Middle East Energy exp...
    How to use PVSYST software🖥️- • Video
    Solar AC cable sizing Calculation👨🏻‍🔧- • Solar AC cable sizing ...
    Solar DC CABLE sizing Calculation👨🏻‍🔧- • Solar DC cable calcula...
    Solar DC earthing systems Calculation👨🏻‍🔧- • Solar DC earthing calc...
    Calculate Solar Plant PR%🌞- • Calculate Solar plant ...
    SOLAR PV modules comparison🔅- • Calculate How to Selec...
    Solar Earth pit resistance Test 👨🏻‍🔧- • Simple Earth pit resis...
    Best Solar panel 🌞cleaning method part 1 - • Best Solar Panel clean...
    Best Solar panel 🌞cleaning method part 2 - • Best Solar Panel clean...
    Renewable energy India Expo♻️- • REI Renewable energy I...
    Solar DC👩‍🔧 string Fault Rectification method - • Solar DC string curren...
    How does solar panels catch fire🔥- • Solar Cell Hotspot, कै...
    Solar cell working in Hindi🌞- • Solar Cell Working in ...
    Rooftop Solar plant visit🌞- • Understand solar plant...
    How to check Solar Delta Inverters👩‍🔧- • Delta Solar string inv...
    Solar Plant thermography test 🔅- • Thermography test of s...

КОМЕНТАРІ • 96

  • @manthanthakkar3951
    @manthanthakkar3951 4 роки тому +8

    Can you mention LA cable sizing with this video than it would be more Informative Video. Thank for your efforts. Doing great job.

  • @sembhi.91
    @sembhi.91 4 роки тому +1

    Thanx bro for LA positioning
    Ma apne rooftop pe 5 kW k setup LGA reha hu to iske poora dheyan rakhuga , apki doom wali bat pehli bar pta lgi .
    Thanx bro apki hr vedio bahut informative hoti hai
    Prmatma tenu chardi kallah ch rakhe .

  • @ask1889
    @ask1889 4 роки тому +3

    Thank you... Very knowledgeable video..you are doing great great towards sustainable world..Keep it up .

  • @nageshk9100
    @nageshk9100 4 роки тому +4

    Nice information BRO...keep om going regarding every aspect of solar power plant ....

  • @nikhilkasar6320
    @nikhilkasar6320 4 роки тому +2

    Thank you bhai for this valuable info also as i said how to calculated earthings for solar pv plant and how meany earthing electrodea need to use which guage and size earthing strip use all about this make one vedio it will very helpfull
    Thank you 🙏

  • @RahulKumar-xh6kn
    @RahulKumar-xh6kn 4 роки тому +2

    @ 17.25 sorry to interrupt you sir but LA height should be 5m from the highest point(min 2 m to product specifications) of installed system not just only from ground.
    Height is taken from the highest installed system, it may be module over MMS.

  • @Solarismypassion
    @Solarismypassion 4 роки тому +1

    Very good 👍

  • @PremSingh-wx3te
    @PremSingh-wx3te 3 роки тому +1

    Highly knowledgeable video.great work

  • @imtiazali4777
    @imtiazali4777 5 місяців тому

    Excellent ❤❤❤ Zinda bad

  • @vikasgajjar4077
    @vikasgajjar4077 4 роки тому

    Really good one sir!! you will be new clone for technology and natural resources-engineering for renewable energy & resources.

  • @SumitVerma-vq6xs
    @SumitVerma-vq6xs 4 роки тому +1

    So informative video. Thank u so much for providing valuable knowledge.

  • @nitinbonakruti7204
    @nitinbonakruti7204 4 роки тому +1

    Good going sir very informative video

  • @senilramani
    @senilramani 4 роки тому +1

    As per NFC code No protection
    provided against fire, electronic failure, Step Voltage, touch Voltage and EMC with ESE.
    As per IEC 62305 above all requirement are comfirm with Conventional Type air Termination Rod.

    • @SustainableEveryDay
      @SustainableEveryDay  4 роки тому +1

      Thanks for the valuable input Senil

    • @itsmywindow
      @itsmywindow 4 роки тому

      What is the relevant code for LA?

    • @itsmywindow
      @itsmywindow 4 роки тому

      Especially, What is the code for selection of LA?

  • @ask1889
    @ask1889 4 роки тому +2

    Please also make videos on ACDB, DCDB & Protection devices like MCCB, SPD, Fuses, Busbar etc.
    Thanks in Advance

  • @dineshmehta3688
    @dineshmehta3688 2 роки тому

    LA cu,Road size L 1.5 mtr, × thicnes 25 mm, & L A connected to 25×3 mm G.I. strip up to la to earthing pit

  • @asadseraj503
    @asadseraj503 3 роки тому

    Too good that’s great keep it app ❤️❤️👍

  • @digitalplatform7911
    @digitalplatform7911 4 роки тому +1

    Thanks for posting this video
    @mithun

  • @adeelqaiser8071
    @adeelqaiser8071 3 роки тому

    Good information dear keep it up...!

  • @zeshanyounis4212
    @zeshanyounis4212 4 роки тому +1

    good information. brother please make a video on how to create new .ond or pan file in pvsyst software.

  • @css1658
    @css1658 2 роки тому +1

    Thank u so much sir

  • @DebjitDas93
    @DebjitDas93 4 роки тому +1

    Excellent content.

  • @Rajpalpooja
    @Rajpalpooja 4 роки тому +1

    Nice information 👍

  • @mohamedsafwan6198
    @mohamedsafwan6198 2 роки тому

    Thanks......

  • @charanteja6424
    @charanteja6424 4 роки тому

    bro, please make a video on how to select ACDB, DCDB, selection of MCB in ACDB. and plase provide any material for complete knowledge on design ofSOLAR ENERGY

  • @najmuddin123456
    @najmuddin123456 4 роки тому +1

    Very nice

  • @solarandwindenergy
    @solarandwindenergy 4 роки тому +1

    Very nice sir

  • @chetankumarsingh1721
    @chetankumarsingh1721 3 роки тому

    Best explanation bhai Maja Aa Gaya

  • @gautamshere8029
    @gautamshere8029 4 роки тому

    Very thanks sir for important information

  • @neerajagarwal5471
    @neerajagarwal5471 4 роки тому +1

    Nice😊

  • @parmeshwarkokate957
    @parmeshwarkokate957 3 роки тому

    Please send me LA redious protection selection formula.
    And calculation discription.

  • @surajgusain7042
    @surajgusain7042 4 роки тому +1

    Thanku sir ji
    Nice video

  • @Minute-cj2pv
    @Minute-cj2pv 4 роки тому +1

    NICE 👍

  • @paragairtel
    @paragairtel 3 роки тому

    Nfc17-102 1995 is old standard now it has been revised and this brand of LA is not proper tested as per nfc17-102 2011

  • @rajendrapagare4948
    @rajendrapagare4948 2 роки тому

    Sir 50kw me LA kon sa lagana chahiye

  • @factsabout3037
    @factsabout3037 3 роки тому +1

    Thanks sir

  • @mknewsnation
    @mknewsnation 4 роки тому

    THANKS FOR SHARING SIR 🙏🙏

  • @EngrJawwadSadiq
    @EngrJawwadSadiq 4 роки тому +1

    Do you have video how to install SPD for small system at home like 5kw ?if had please share link.

  • @shankarbasavaiah6776
    @shankarbasavaiah6776 3 роки тому

    How much it cost for 4 storied building, is it necessary to keep LA rod in the centre of the building if solar panels are present, because top of the building is at the other end ( staircase room)

  • @batistafrose6009
    @batistafrose6009 3 роки тому

    Sir Nice video which( L A) is Better sir for Rcc Building.

  • @SuperJohnelton
    @SuperJohnelton 4 роки тому

    As per national building code (NBC) they have banded ESE type LA.
    We are using angle terminal rods nowadays.
    www.dehn-international.com/store/p/en-DE/F14661/angled-air-termination-tips

  • @dineshmehta3688
    @dineshmehta3688 2 роки тому

    Two three day lifhtining strik heppen near my building on solar plant L A. Strik gon down to earth by LA but sum electric instolation fail why this is heppen i have strik video, dinesh mehta mumbai borivali( i cheq in thet building but i cant.haw to buent sum thing)

    • @SustainableEveryDay
      @SustainableEveryDay  2 роки тому

      I sir unable to understand your case can you share some more data on ly linkdin

  • @Anwarali-zj1qh
    @Anwarali-zj1qh 4 роки тому +1

    Solar panel ke pass LA rod lagaye baadme jo bizli hai vo niche giregi ya kidar giregi ..please information diyo sir

  • @jspreet_j5481
    @jspreet_j5481 2 роки тому +1

    Sir, from where i cn get these type of lightning arresters

  • @digvijaysingh124
    @digvijaysingh124 2 роки тому

    Sir, as you told, if the lightning falls, then we can save our solar system by light arrester, but there is one more problem that how to save the solar system from hailstone

  • @infosolartechindia1498
    @infosolartechindia1498 3 роки тому +1

    If my solar panel is of 4m height , having 10m radius of roof then can I use 2m height LA

  • @baljeet9892
    @baljeet9892 4 роки тому

    LA Strip 25×3 MM Insulate With Wall Mandatory or Not.Minimum Conductor(Flexible) size in sq mm for Structure & Inverter Earthing.Please Reply Both Questions.

  • @vishal-ln5xe
    @vishal-ln5xe 4 роки тому

    Sir,how type of shape protection provde An ESE LA,which means its cover a Cone type shape or cylendrical shape or Egg type shape.

    • @SustainableEveryDay
      @SustainableEveryDay  4 роки тому +1

      Any shape is ok , just check the catalogue for its protection range based on its design

  • @abuzarbanderkar5190
    @abuzarbanderkar5190 4 роки тому

    Himanshu,which app u have usedrwriting?
    And did u used graphics tablet for writing on scree?

  • @tusharbhakare2396
    @tusharbhakare2396 4 роки тому +1

    LA cable pe video banao sir tnx

  • @roshanaykhan3337
    @roshanaykhan3337 Рік тому

    Description mn ye document nhn mil ra download krny k lye

  • @mukeshnishad1272
    @mukeshnishad1272 3 роки тому

    Does Sir Lighting Arrester Attract Lighting?
    Please sir answer me

    • @SustainableEveryDay
      @SustainableEveryDay  3 роки тому

      No it doesn't attract light , it offers low resistance path for lighting strike

  • @Ashishyadav-iv6un
    @Ashishyadav-iv6un 4 роки тому

    Is it necessary to install a lightning arrestor if we are surrounded by more taller buildings and mobile tower than us?

  • @baljeet9892
    @baljeet9892 4 роки тому

    Minimum Size Of Down Conductor In Sq MM (Flexible Green Cable) For Conventional Ligtening Arrester Spike Type.Please Reply Fast.

    • @SustainableEveryDay
      @SustainableEveryDay  4 роки тому +1

      16sqmm but still not recommended , always use GI strip 25x3 mm

    • @baljeet9892
      @baljeet9892 4 роки тому

      @@SustainableEveryDay And Also Below 10 Kw & 10KW LA Is Mandatory or Not In India.

  • @sembhi.91
    @sembhi.91 4 роки тому +1

    CK

  • @ask1889
    @ask1889 4 роки тому +1

    What about earthing conductor size and no of earthing pits for LA ??

    • @SustainableEveryDay
      @SustainableEveryDay  4 роки тому

      Hi Ajay , regarding different types of earthing techniques I am making separate videos

    • @ask1889
      @ask1889 4 роки тому +1

      What will be the earthing wire or strip size for LA

    • @SustainableEveryDay
      @SustainableEveryDay  4 роки тому

      It will depend on the fault current value of the system , already I have made a video on it ua-cam.com/video/bIe9KNiG7X4/v-deo.html

  • @abbasranala
    @abbasranala 4 роки тому

    namaste.sir.med.in.india.top.1o.penal.konse.he.sir?

  • @sunilteli6268
    @sunilteli6268 4 роки тому +1

    thanks sir ji