  • @cristianbogdan4954
    @cristianbogdan4954 7 місяців тому

    With this device was impossible to check I-V curve for N type PV panels. I have try with two model (astroenergy CHSM54N-HC 425Wp and trina other model ) and the device returns error no. 14 - Isc current overloaded. I have send the panels to a laboratory and and they are good. It is not written anywhere that N type panels cannot be tested.

    • @BassamAlborsan
      @BassamAlborsan 4 місяці тому

      the same problem, although data sheet 20 A, you find the solution?

  • @BassamAlborsan
    @BassamAlborsan 5 місяців тому

    find a problem with this tool, it doesn't measure module panel more than 15 amper and data sheet this tools until20 A.

    • @PhOeNiX13162
      @PhOeNiX13162 2 місяці тому

      You got a solution?
      We're recently working with the HT PVChecks PV Tester and there's an option in the moduleconfiguration to set the module technology to capacitiv, which allows higher currents although it's only capable of 15A max.