COM23. EtherNet/IP - Beckhoff TwinCAT 3 (TF6281) Ethernet/IP Master(Scanner) and Real Hardware Test

Поділитися
Вставка
  • Опубліковано 10 лют 2025

КОМЕНТАРІ • 26

  • @lmathew78
    @lmathew78 6 місяців тому +1

    Great presentation. Wonderful. helped me

  • @aureliusbagas1494
    @aureliusbagas1494 Рік тому

    hi im using sig200 for my sensor integration gateway. im using multi physics box from sick. im having a problem, im done scanning the sig200 when i add io connection i didn't get the value. all the value is 0. i already add the eds file. can you help me?

  • @grandwizardnoticer8975
    @grandwizardnoticer8975 Рік тому

    Crazy how most all of this info is not in the manual for TF6281.
    Beckhoff?

  • @hw6994
    @hw6994 2 місяці тому

    谢谢,非常有用!

  • @dmacJessy
    @dmacJessy 6 місяців тому

    Helped me out! Working with Beckhoff EL6652 to AB Mirco 850E Communication.

  • @valentinpomirleanu1281
    @valentinpomirleanu1281 2 роки тому

    Hi, I'm using an Ethernet/IP scanner to communicate with a chiller but the connection times out as soon as it is established. I have played with the Sync Task duration and i have tried many other thing but I don't know what to do to it anymore...

    • @electricalautomation
      @electricalautomation  2 роки тому

      I would recommend decrease the EIP cycle time to 20ms or even 50ms for the test. Does the chiller has EDS file?

    • @valentinpomirleanu1281
      @valentinpomirleanu1281 2 роки тому

      It's without EDS. I have tried what you have suggested with no success. I'm in contact with HMS support, they believe that the chiller company used the wrong gateway for the communication...

  • @tuonghoasiemens456
    @tuonghoasiemens456 2 роки тому

    Great sample, Is it possible to use Ethercat Master software for TwinCAT 3 on our laptop? I did on my laptop, TwinCAT does show error when building and running, but It does not get data from EthernetIP adapter too

    • @electricalautomation
      @electricalautomation  2 роки тому

      Thanks for watching! Yes, you can use your laptop for the test, but your ethernet adapter in your laptop MUST BE INTERL chipset. In addition, have you set the Ethernet Card successfully? as shown 10:20 in the video.

  • @gagarin9311
    @gagarin9311 Рік тому

    great tutorial. Very helpful :D

  • @GuitarHeavenPL
    @GuitarHeavenPL 3 роки тому

    Thanks for the informative video

  • @zm6306
    @zm6306 2 роки тому

    How it could be done the communication between 2 beckhoff PLCs?

    • @electricalautomation
      @electricalautomation  2 роки тому

      ADS, for two Beckhoff PLCs. Pls see the link: www.plccoder.com/communicating-between-beckhoff-controllers-part-2-ads/

    • @zm6306
      @zm6306 2 роки тому

      @@electricalautomation thank you but I mean the communication between 2 Beckhoff PLCs with ethernet IP. I created a scanner as shown in this video and then created an adapter but it is not working ( with Allan Bradley it is easy but to do the communication between 2 beckhoff PLCs it seems impossible)

    • @electricalautomation
      @electricalautomation  2 роки тому

      @@zm6306 Hello, please review the videos COM14. EtherNet/IP - Beckhoff TwinCAT 3 (TF6280 Adapter) and Allen-Bradley CompactLogix PLC (Master) ua-cam.com/video/LRqR66C3uLw/v-deo.html ; COM23. EtherNet/IP - Beckhoff TwinCAT 3 (TF6281) Ethernet/IP Master(Scanner) and Real Hardware Test ua-cam.com/video/y9zqib_EieA/v-deo.html. Please review them carefully, I believe you missed some configuration.

  • @aitoufkirimad9010
    @aitoufkirimad9010 Рік тому

    THE BEST

  • @bjornforssberg5555
    @bjornforssberg5555 3 роки тому

    Very good introductions on your ! Can I set a link to them on my homepage?

  • @elizeusimoes490
    @elizeusimoes490 3 роки тому

    👏👏👏👏👏👏👏Very good