Section 1.10.1.15 (C-1) of PEC 2017 Temperature Limitation (1) Equipment provision a.) Termination provisions of equipment for circuits rated 100ampere or less, or marked for 2.0mm2 through 38mm2 conductor, shall be used only for one of the following: 1. Conductor rated 60deg.C 2. Conductors w higher temp. Ratings, provided the ampacity of such conductors is determined based on the 60deg.C ampacity of the conductor size used. 3. Conductors w/ higher temp. Ratings of the equip. Is listed and identified for use w/ such conductors. 4. For motors marked with design letters B, C, or D, conductors having insulation rating of 75deg.C or higher shall be permitted to be used, provided the ampacity of such conductors does not exceed the 75deg.C ampacity. b.) Termination provisions of equipment for circuits rated over 100Amperes, or marked for conductors larger than 38mm2, shall be used only for one of the following: 1. Conductors rated 75deg.C 2. Conductors with higher temp. Ratings, provided the ampacity of such conductors does not exceed the 75deg.C ampacity of the conductor size used, or up to their ampacity if the equipment is listed and identified for use with such conductors. Thanks sir! I'm learning a lot from you.
Thumbs up sir. Maganda ang pagkagawa ng presentation at sakto dahil ginamit talaga ang mga factors na nakaka-appekto sa pagsize ng wires gaya ng Over irradiance, Continuous Duty, Correction factors, Adjustment factor (Conductor Bundling) at Voltage Drop computation. 👍
Nice tutorial.magastos pala yang solar tutal nasa ncr namsn ako wag nalang saka matagal r.o.i. ibibness q nlang pera q jan.buy nlang me generaror nasa 5k .wala pa sskit ulo saka madalang naman brown out.tnx
in short , simpling explanation..pag meron ka 40-100w na solar panel ay pwedi ka gumamit ng solar cable na 10-12awg...pag pataas na 100w and above ang 8-10awg solar wire lang ang pinaka safe at practical na gamitin...ganun lang, yun lang..simpling expalanation hahaha.
Pa request naman po about sa Wind turbine vs. Solar panel. Efficiency at kung magkano magagastos sa pag build at kung ilang taon ang lifespan ng wind turbine.TIA Kalecky.
Sir, clarification ko lng. Dun po sa Voltage Drop Calculation nakalagay Series Connection? Pero gamit po natin sa Computation 17.8. (8.9(Isc)*2) I supposed Parallel Connection. Tapos pag dating nmn sa %VD = (Vdrop/Vmp)*100 = (Vdrop/72V)*100, I supposed 72V series Parallel Connection. Natutunan or napansin ko lng dn to dahil na rin sa tutorial mo sa Voltage Drop. Hndi po talaga ako marunong 😁, Salamat Sir sa mga tutorial dami ko natutunan. Pa clarify lng po, GodBless.
Clarification lang po sir. Since yung temperature rating ng TW ay 60°C, di po ba dapat yung iapply na correction factor ay dapat under 60°C din not the 90°C?
Kaya po ba ng 10mm2 PV cable ang 2p2s? If the value is: ISC 10.48A x 2 =20.96A x 1.25 x 1.25= 32.75A 10mm2 is not actually 8awg but 7.2? Tama po ba ito? Nakakalito po kasi na halos lahat ng ampacity table ay base sa imperial. Wala po bang exact conversion na para sa metric? Kung hindi kakayanin ng 10mm2 ang 2p2s na may ISC 10.48A, 16mm2 ang kasunod na wire. Hindi naman po mahirap maghanap ng 16mm2 PV cable at MC4 na 16mm2? Salamat po sa pagsagot sa katanungan.
Pero in case sa 3S4P na set up, yong first computation applicable for 3S wires connected to 4in1 Y connector(MC4) tapos SUM ng 4P Isc naman ang babasihan for computation para sa wire from 4in1 Y connector(MC4) to SCC since mag a-add Isc sa parallel? Bali lalabas na scenario papalaki yong wire 3S to 4in1 Y connector(MC4) then 4in1 Y connector(MC4) to SCC. tama din po ba sir na same principle ang computation ng Isc sa series at parallel?
morning po sir.tanong kolang po.may battery po akong ginagamit 12v.galing sa sadakyan konse.tanong kolang po kong anong dapat gamitin na solar panel 18V.oh 24V.na solar panel at ilang watts ang tugma maraming salamat po.
Pwdi po ung TW 14 sa battery to solar charge controller boss idol?tapos ung sa solar panel ko 120watts ung 16/2- 1.25mm ung para sa extension cord namin..?pwdi po ba?
Hello bossing, kung ang service entrance wire ko is size #8, kya lang ung galing sa source (electric company) is #10 lang, ano effect nun sa electrical system nung hauz ko...ty
by right po wala po dapat effect sa inyo, nasa tama po minimum wire size nyo po kung my issue po baka sobrang layo nyo na from transformer or madaming bahayan sa area nyo tapos my mga welding, pero kung safety po sa bahay nyo ok na po ang #8 as minimum wire size given na pasok sa mga load computation nyo
Idol! Lagi akong nanunood ng mga videos u. Gusto q mga videos mo dahil marami ako natutunan. But if you don't mind. Curious lng. Bakit nga ba magkaiba ang ginagamit na wire sa dc kesa sa ac. For example Thhn usually used for domestic wiring. Pero for dc wiring, usually finer ang strands like sa solar pv panels and batteries. I hope you can explain it for another video and how to size wires for batteries. Muli, salamat sa magaganda at informative videos mo! God bless kalecky!
Pero in case sa 3S4P na set up, yong first computation applicable for 3S wires connected to 4in1 Y connector(MC4) tapos SUM ng 4P Isc naman ang babasihan for computation para sa wire from 4in1 Y connector(MC4) to SCC since mag a-add Isc sa parallel? Bali lalabas na scenario papalaki yong wire 3S to 4in1 Y connector(MC4) then 4in1 Y connector(MC4) to SCC. tama din po ba sir na same principle ang computation ng Isc sa series at parallel?
Section 1.10.1.15 (C-1) of PEC 2017 Temperature Limitation (1) Equipment provision
a.) Termination provisions of equipment for circuits rated 100ampere or less, or marked for 2.0mm2 through 38mm2 conductor, shall be used only for one of the following:
1. Conductor rated 60deg.C
2. Conductors w higher temp. Ratings, provided the ampacity of such conductors is determined based on the 60deg.C ampacity of the conductor size used.
3. Conductors w/ higher temp. Ratings of the equip. Is listed and identified for use w/ such conductors.
4. For motors marked with design letters B, C, or D, conductors having insulation rating of 75deg.C or higher shall be permitted to be used, provided the ampacity of such conductors does not exceed the 75deg.C ampacity.
b.) Termination provisions of equipment for circuits rated over 100Amperes, or marked for conductors larger than 38mm2, shall be used only for one of the following:
1. Conductors rated 75deg.C
2. Conductors with higher temp. Ratings, provided the ampacity of such conductors does not exceed the 75deg.C ampacity of the conductor size used, or up to their ampacity if the equipment is listed and identified for use with such conductors.
Thanks sir! I'm learning a lot from you.
Thanks for sharing.. apir
@@KALECKYTV ako dapat magpa salamat sir!
More power po sir!
Apir!
Ang ganda ng content, madaling maintindihan. Claro ang mensahe. Thank you sir. Di na masalimuot ang wire sizing 😆
1st 8mins napasubcribe ako sa sobrang detail mo. 1st day of learning to setup solar
subrang technical sa akin na walang alam sa electricity sir at newbie pa sa solar serup😍 anyway very informative naman kung maiintindihan!
Thumbs up sir.
Maganda ang pagkagawa ng presentation at sakto dahil ginamit talaga ang mga factors na nakaka-appekto sa pagsize ng wires gaya ng Over irradiance, Continuous Duty, Correction factors, Adjustment factor (Conductor Bundling) at Voltage Drop computation.
👍
Kaya dapat magseries. Para tumaas ang voltage at bumaba ang current.. mas maliit na wire kailangan mo..😊😊
Nice tutorial.magastos pala yang solar tutal nasa ncr namsn ako wag nalang saka matagal r.o.i. ibibness q nlang pera q jan.buy nlang me generaror nasa 5k .wala pa sskit ulo saka madalang naman brown out.tnx
#12 AWG na po ang minimum wire size para sa residentials, di na po ginagamit ang #14 AWG.. thanks po sa mga video avid follower here.
Good info kabaro maganda ito big help sa mga nais mag pakabit ng solar panel
natatawa lang ako dun sa 14awg naging 8awg.. pero nagalingan ako.. salamat sa tinuro mong correction ngayon ko lang nalaman ang mga ganyang correction
Correction sir. THHN is not designed on exposed environments... madaling mapulbos yung insulation kalaunan
in short , simpling explanation..pag meron ka 40-100w na solar panel ay pwedi ka gumamit ng solar cable na 10-12awg...pag pataas na 100w and above ang 8-10awg solar wire lang ang pinaka safe at practical na gamitin...ganun lang, yun lang..simpling expalanation hahaha.
Dami natutunan sa mga content mo idol, bago mong tagasubaybay, pwede nba number 10thhn na wire galing breaker papuntang solar set up, tnx.
Pa request naman po about sa Wind turbine vs. Solar panel. Efficiency at kung magkano magagastos sa pag build at kung ilang taon ang lifespan ng wind turbine.TIA Kalecky.
Salamat po sa advise.My nakuha na akong idea maraming salamat po.
Fantastic, very clear info, big thumbs up
ayos sir, thanks for this very important information
Panibagong kaalaman naman KALECKY! Apir ✋ Isang HEART nga dyan KALECKY ☺
sakto kalecky,. mag seset. up ako next month 3kw safe wire is needed
Good morning nabanggit mo na Kung mag upgrade sa solar,mag upgrade k din na sa Grid tie inverter
Sir, clarification ko lng.
Dun po sa Voltage Drop Calculation nakalagay Series Connection?
Pero gamit po natin sa Computation 17.8. (8.9(Isc)*2) I supposed Parallel Connection.
Tapos pag dating nmn sa
%VD = (Vdrop/Vmp)*100
= (Vdrop/72V)*100, I supposed 72V series Parallel Connection.
Natutunan or napansin ko lng dn to dahil na rin sa tutorial mo sa Voltage Drop. Hndi po talaga ako marunong 😁, Salamat Sir sa mga tutorial dami ko natutunan.
Pa clarify lng po, GodBless.
Good morning kaleck
idol oky lng ba n pag sa mahin ang magkaiba ang battery na 2SMMF at NS60LS oky lng ba pasamahin
Good morning idol..god bless
Idol, gawan moko ng computation ng size wire ng aking 555wtts na panel anong size ang nababagay pls reply...
Clarification lang po sir. Since yung temperature rating ng TW ay 60°C, di po ba dapat yung iapply na correction factor ay dapat under 60°C din not the 90°C?
Sir pwedi q ba gamitin ang #14 THHN para sa 12v DC lights?
sir pwede bang paki explain yung length ng wire sa current at load paano Malaman ang current sa length ng wire considered na yung ibang factor
Boss anung magandang wire para sa 100 wats na solar pang Bahay
Bakit sa derating factor ng cable sir eh 60 deg. TW...napunta sa 90 deg
Un oh..solid❣️🥰🙏
Lods pwede gumamit ng malaking wire kahit hindi malakas yung kuryente
Kaya po ba ng 10mm2 PV cable ang 2p2s? If the value is:
ISC 10.48A x 2 =20.96A x 1.25 x 1.25= 32.75A
10mm2 is not actually 8awg but 7.2? Tama po ba ito?
Nakakalito po kasi na halos lahat ng ampacity table ay base sa imperial.
Wala po bang exact conversion na para sa metric?
Kung hindi kakayanin ng 10mm2 ang 2p2s na may ISC 10.48A, 16mm2 ang kasunod na wire.
Hindi naman po mahirap maghanap ng 16mm2 PV cable at MC4 na 16mm2?
Salamat po sa pagsagot sa katanungan.
Sir may silicon pova nyan na awg ung silicon malambot at maraming hibla sir tapus ung single wire lng at matigas
Boss, pwede po ba na mas malaking wire gamitin na econnect na extension dun sa wire ng Solar panel? Thanks.
Ka lecky saan tau makabili ng grid tie solar inverter?
Boss, pwede bang gamitin ang AUTOMOTIVE WIRE? wala ka kasing nabangit sa mga wire e salamat. ✌️✌️✌️🙏🙏
About royal cord sir applicable din ba sa expose..
Gue eve sir may pwm akong scc 20amp pde pova cia sa 200watts na panel
Pero in case sa 3S4P na set up, yong first computation applicable for 3S wires connected to 4in1 Y connector(MC4) tapos SUM ng 4P Isc naman ang babasihan for computation para sa wire from 4in1 Y connector(MC4) to SCC since mag a-add Isc sa parallel? Bali lalabas na scenario papalaki yong wire 3S to 4in1 Y connector(MC4) then 4in1 Y connector(MC4) to SCC. tama din po ba sir na same principle ang computation ng Isc sa series at parallel?
Anu Po bang tamang wire para 350 na solar panel at vatt?
Sir Ok na poba ang 6mm² twin core pv cable sa solar panel na 100w?
Halimbawa may install na ilaw sa bahay tpos ngpalit sila ng solar panel na 100watts need pa po ba mg palit ng wire at ilaw o hnd na?
sir kapag DC voltage may kalimitan ba Ang haba ng wire na dapat gamitin? Kung Meron hangang ilang meters lng po ba?
Oct.2,2024
boss AWG#18 automotive wire pwdy bagamitin mula sa panel ko 100watts
salute sir lek👍👍👍👍👍👍👍👍👍🍺🍺🍺
11.69 amp
42.80v
6 pcs series in parelled
=23.38A in 20-meter wire.. 8awg ba sir?.
Pwede bang #12 royal cord sa solar panel
Salamat for sharing knowledge sir👉👈👌
Boss may ma iirecomenda ka ba ba puedeng mag kabit na solar sa bahay ko
Sir puede ba yung 10mm na stranded wire
how about sir kung apat na 4na wire in parallel ang gamitin para hindi na magbago ng wire size. pwede kaya un
Pag gumamit ako ng 6awg for my setup na 2kw solar panel. Ilang anong ampere ng breaker gagamitin ko?
sir kalecky hybrid inverter nmn po with battery wiring diagram po,,
Ask ko po pwede po b gamitin T.W wire sa PV?
Silicone o copper ?
Breaker sizing naman po
pwede npo ba yung 18awg sa 12v20watts na panel?
Sir..gud a.m. magkano ang presyo sa inverter dyan sa manila...3kw.24v...pure sine wave toroidal....
di po ko installer pero usually mas mura na sa shope at lazada, nung nag check ko last time mas ok na brand ay snat
35watts lang po yung panel ko sir, may wire po ako kahit ba maliit ang panel eh pwede yung mga makakapal na wire?
morning po sir.tanong kolang po.may battery po akong ginagamit 12v.galing sa sadakyan konse.tanong kolang po kong anong dapat gamitin na solar panel 18V.oh 24V.na solar panel at ilang watts ang tugma maraming salamat po.
12 volts yung bat, dapat 12 volts solar panel dn
Pwdi po ung TW 14 sa battery to solar charge controller boss idol?tapos ung sa solar panel ko 120watts ung 16/2- 1.25mm ung para sa extension cord namin..?pwdi po ba?
Sir, Isc na ginamit is for single panel lang? If naka combination need ba itotal yung Isc?
Kung parallel i think need mo e total
Sir ok lang ba #8 thhn o 5.5mm gamit ko pandugtong from solar panel to scc?
sir, good day...yung sinasabi mo. 8 wire , ito ba ang 4mm or 6mm ? pasensya wala akong alam eh
Sir pde makahingi ng excel files mo yn na meron ng computation para key in n lng nmin yung data. Thanks
Lec para man ka hinahabol binabasa mo ba yan hehehe
Hello bossing, kung ang service entrance wire ko is size #8, kya lang ung galing sa source (electric company) is #10 lang, ano effect nun sa electrical system nung hauz ko...ty
by right po wala po dapat effect sa inyo, nasa tama po minimum wire size nyo po kung my issue po baka sobrang layo nyo na from transformer or madaming bahayan sa area nyo tapos my mga welding, pero kung safety po sa bahay nyo ok na po ang #8 as minimum wire size given na pasok sa mga load computation nyo
Ok lang yun, at least safe ang bahay mo..
Problema na ni meralco na maliit wire nila
AGAndang umaga mga kalecky viewers!🙌
Idol! Lagi akong nanunood ng mga videos u. Gusto q mga videos mo dahil marami ako natutunan. But if you don't mind. Curious lng. Bakit nga ba magkaiba ang ginagamit na wire sa dc kesa sa ac. For example Thhn usually used for domestic wiring. Pero for dc wiring, usually finer ang strands like sa solar pv panels and batteries. I hope you can explain it for another video and how to size wires for batteries. Muli, salamat sa magaganda at informative videos mo! God bless kalecky!
equipment has no "S"
1st kalecky...👏🕊👍
Gudnyt hehe
Morning na po uyyy....😉
hasel
Ka boses mo chief si michael fajatin
galing pota
Kaboses mo yung manyakis na vlogger yung pinaghahanap ngayon kasi puro kabastosan topic. Usapang diskarte yung channel
Panibagong kaalaman naman KALECKY! Apir ✋ Isang HEART nga dyan KALECKY ☺
Pero in case sa 3S4P na set up, yong first computation applicable for 3S wires connected to 4in1 Y connector(MC4) tapos SUM ng 4P Isc naman ang babasihan for computation para sa wire from 4in1 Y connector(MC4) to SCC since mag a-add Isc sa parallel? Bali lalabas na scenario papalaki yong wire 3S to 4in1 Y connector(MC4) then 4in1 Y connector(MC4) to SCC. tama din po ba sir na same principle ang computation ng Isc sa series at parallel?