Solax power 6kw complete information installed |6kw solax power
Вставка
- Опубліковано 26 кві 2024
- solaxsolax powersolax invertersolax solar inverter,solax solar 6kw hybrid inverter installed,solax power's latest solar inverters,solar installation,solar power international.,what's new in solax power inverters,solax power inverter,solar system installation,solax power on grid hybrid inverterssolar
Masha Allah bhai ap boht achy trha smjty ho or Allah Pak ap ko khush rakhy Ameen
Aamen
DP box safety ko maad e nazar rakhtay huway Inverter key neechay nahee rakhna chahiyae.
How to check battery percentage on solax on tubular batteries
❤❤❤
Keep it up sir
Kia ya system Amp Wapda say. Lata rahta ha
Dear Sir, need your kind advice please. I have recently installed a 6kw solar system through a vendor in Peshawar. We have installed the same Solax 6kw Hybrid Inverter with 12 N-Type A grade 585w solar panels (which makes it a 7kw). We have not installed a battery yet because there is only 3 hours of loadshedding in my area during the day time (and I ran out of budget as well). It shall be noted that I have only two 1.5 ton Full DC inverter ACs, a normal size fridge, 3 ceiling fans (60w), and some light. The average load of the house is around ~3.5kw.
Suppose at 10:56am when the solar system is producing power at peak level, it would be supporting the entire load of the house and even exporting some to the Green Meter as well (which is yet to be installed). Now the problem is that as the grid goes off at 11am (loadshedding), the inverter would trip and would show DCBUS_SW_UVP error on it. It then restarts and immediately trips again and continues unless I manually go and switch off the both ACs and the Fridge. I contacted the vendor many times and they visited many times but could not fix it. Today they shared that it is the nano-second torque of the ACs, and probably the Fridge, that trips the inverter and does not let it the PV's increasing flow to the inverter. They recommended that you should install (min 48v) battery/batteries to help with the torque to have the system running and pass through without tripping.
Can you please help? What should I do?
you should install battery to support initial torque load
Yes install 48 volt battery
Even 100 ah 4 battery 12 volt make a series
Kahan se mile ga
Aour price kia hy
Firmware update karnay ka tareeqa bhi bataein/
Solax 6 kv parallel total 12 kv 28 plates 4 batries system
Slave me, Inv hw ocp
Master me parallel sub fault show krta he din me 2 se 3 martaba phr system restart ho jata he is ka koi solution
Invertor kitny ka aia
what is the wattage of each panel ?
Kea is may timer be hay 11 :40 par rooz sun to electric meter par ho jata. hay phir shud down kary to ok hota hay
G timer ha
CT Ki setting kara de
Mera solax 6kw inventor no export select hy phir bhi thora power meter ko feed karaha hy jis ki waja se meter pe reverse light arahi hy, mery meter green meter nhi hy or us se sirf mera floor chalta hy, kia waja hu sakti hy???
Waring problem
Is inverter kay sat sirf solax ki lithium battery install hogi agar narada ka lithi bank install karna chahu toh wo kam nahi karay ga
try installing it with cat 6 cable
kia yeh inverter serf single source solar pay chal jae ga without batteries and grid
Maine Liya h kal dekhte hain installer aye laga kr k de to pta chalega
@@mrallrounder6065 kitny ka liya hai? aur kahan se?
@@mrallrounder6065 bhai apne check kiya kesa chal rha hai ?
Your experience?@@mrallrounder6065
Wrong installion, db should be 2 meter away from inverter
Waja?
Bhai jab rat ko wapda ahti hai to invertor jatka kha k off hota hai ek bar please help
Did your problem solved?
@@khushab99 wapda wali to solve ho gaye per meny inverter bs change kar deya
@@khushab99same problem please guide.. wapda ate hi system restart hojata he
Or subah k time pe b system restart hota rehta h 2 se 3 martaba din me mera 12 kv 6 kv parallel 28 plates 4 batries ka system laga hwa h.
Or ye fault show krta he
Slave me Inv hw ocp
Master me. Parallel sub fault
@@footballiseverything8170sir apka wapda ane per restart wala masla kese hal hoa.guide me please
Assalam o Alaikum
Bhai startup condition fail ka error araha he
Kindly guide karen
Program setup thek save kray
السلام علیکم ورحمۃ اللہ وبرکاتہ بھائی اگر اپ کو کوئی اعتراض نہ ہو تو اس انویٹر کی قیمت بتا سکتے ہیں اگر ہو سکے تو اسی ماڈل میں 6 کلو واٹ اور 8 کلو واٹ کی بھی قیمت بتا دیں بھائی ابھی بتائیں کہ اس میں کم از کم اور زیادہ سے زیادہ کتنے بینل اور کتنے واٹ کے پینل لگا سکتے ہیں۔ اس انویٹر کے ساتھ چار بیٹریاں لگانی ہوگی اور کم از کم کتنے امپیر کی بیٹریاں ہوں ۔ اگر اپ 6 کلو واٹ کا سسٹم انسٹال کروانا ہے تو ٹوٹل خرچہ بتا دیں اس کا کہ کتنے ٹائم میں لگ سکتا ہے اور کتنے کا لگے گا جزاک اللہ بہت شکریہ اور اپ کا کام ماشاءاللہ بہت اچھا لگا ہے اور بہت اچھے طریقے سے سمجھاتے ہیں جزاک اللہ بہت بہت شکریہ۔
03026034771 WhatsApp pa rabata kray
Bhai jaan yah bhi Bata de please is inverter per kitne wat ke maximum panel Laga sakte hain
16
585
Contact number for Sadiqabad
03093863630
6 kw ka inverter ki kaya price hai? Contact number share karein.
03093863630
Rs270
Kahan se mily ga address dy dain plz@@muhammedshahbaz-zuhan
Assalam o Alaikum hru Sir 1 problem hai main solax inverter use kar raha hun last 8 din sai kal light gai to sab 00 a gia inverter on raha battrey nai lagi sath full peak par chal raha tha @@muhammedshahbaz-zuhan