Power System Analysis (fault analysis)-1

Поділитися
Вставка
  • Опубліковано 11 вер 2024
  • power system Analysis
    for doubts you can visit apexclass.in/

КОМЕНТАРІ • 105

  • @guardianangel141
    @guardianangel141 5 років тому +10

    Great video! thank you for sharing and explaining EXTREMELY clearly! I really appreciate that you take your time with each step! Thanks again!

  • @aymanantoun8898
    @aymanantoun8898 5 років тому +3

    Professor you are the best as usual
    The most professional one on UA-cam knows how to make the lecture very easy to understand and anyone can follow you
    You have skills to be a teacher better than professors/PHD teaching in university
    I greatly appreciate your time and your lecture I enjoyed so much

  • @jlianmnses6677
    @jlianmnses6677 4 роки тому +2

    Sir You are an excellent teacher, very methodical, paced and articulate. I would have benefited greatly should you have been my teacher in college, thank you so much for this video and I look forward to future ones related to short circuit calculation analysis.

  • @DestructZero
    @DestructZero 5 років тому +2

    Hey Abhishek I hope your day is going well. I'm currently reviewing my Electrical Power Engineering notes and problems. Your video provides an excellent example that covers a variety of topics a practicing Engineer will encounter. This is the first time I've seem your UA-cam channel. I will definitely be viewing the rest of your videos. Keep up the good work.

  • @bernardomunoz8721
    @bernardomunoz8721 Рік тому

    Wonderful explanation on Power Systems Fault Analysis. All my Electrical Engineering colleagues should follow this.

  • @eliemutia4620
    @eliemutia4620 2 роки тому

    Thank youuuu, my tutor didnt even understand what he was teaching but you have made it super clear!!

  • @dragon725
    @dragon725 2 роки тому +2

    Thank you Sir for excellent lecture. never seen like this clear explanation !!

  • @prjawahar5879
    @prjawahar5879 6 років тому +2

    Good one. I also find it to be more convenient to work all on 1 MVA basis by dividing all PU values by respective equipment MVA rating. Finally just add up all PU values (Xsum) and divide 1000kVa/ root3 × 22kV× Xsum. (I.e., Xsum= 0.15/25+0.09/30+0.092/100+ 0.02/5)

  • @ghostxaxom1087
    @ghostxaxom1087 3 роки тому

    Thanks a lot sir. Exams se pehle bacha liya aapke video ne. keep up the good work. Easy to understand and learnt ASAP.

  • @pietervdberg7055
    @pietervdberg7055 Рік тому

    Thank you for a good, clear, understandable lecture. I like the practical example all the way through from start to finish.

  • @madhuvimal88
    @madhuvimal88 3 роки тому

    Base value and base voltage selection concept... Super...
    🙏👌

  • @mharjunjacer5694
    @mharjunjacer5694 3 роки тому +1

    I understand everything you're a great Instructor.

  • @DestructZero
    @DestructZero 5 років тому

    Thanks for sharing the video Abhishek. I'm currently reviewing my Electrical Power distribution notes and this video has been very helpful. Hope you share more videos like this in the future. Cheers.

  • @samyhubbi9400
    @samyhubbi9400 Рік тому

    Thank you man finally the video I was looking for

  • @arpansaha5745
    @arpansaha5745 6 років тому +1

    thanks sir for making my concept clear i was your student only sir from srm university

  • @KAFKUBA
    @KAFKUBA 5 місяців тому

    To get fault current I would have divided generator voltage by all line impedances... is that wrong?

  • @oguzgurler8856
    @oguzgurler8856 4 роки тому +1

    why do we ignore the voltage drop across the transmission line? And how do we get the given per units on the SLD?

  • @MudasirHussain-o9s
    @MudasirHussain-o9s 6 років тому

    Great... The art of teaching is excellent

  • @OmarRodriguez-qz5tf
    @OmarRodriguez-qz5tf 4 роки тому

    Good explanation, it was a good idea the use of paralel lines to determine the per unit values, i had never seen it befor, congratulations

  • @sungmopark0405
    @sungmopark0405 5 років тому +2

    Can you explain why symmetrical fault
    L-L-L-G and L-L-L is same?

  • @halfengineer5
    @halfengineer5 3 роки тому +1

    that actual fault current is phase current or line current?

  • @masikapignacio2069
    @masikapignacio2069 4 роки тому +1

    thank you sir for your video. Can I request example regarding of having a given details in the load. like you've said if there is a synchronous motor. Thanks!

  • @pauljarju6127
    @pauljarju6127 9 місяців тому

    Thanks for the explanation

  • @shubhambhandari415
    @shubhambhandari415 5 років тому

    Well job, superb lecture u wash out my doubts

  • @AshrafulIslam-bz2ui
    @AshrafulIslam-bz2ui 3 роки тому

    Thanks and love from Bangladesh

  • @sohailjanjua123
    @sohailjanjua123 3 роки тому

    Hi Abhishek , I like your lecture. Thanks

  • @sumitmondal548
    @sumitmondal548 3 роки тому

    Did you work out this problem by MVA method or ohmic impedance method?? MVA method with ms Excel gives same result.

  • @aymanantoun8898
    @aymanantoun8898 6 років тому

    Excellent video as usual
    Professor Please if in the same problem the load is dynamic how we obtain the regally voltage and the internal voltage of the generator?

  • @1dennisjonathan
    @1dennisjonathan 3 роки тому

    Hi, I used 25MVA as the power base. Generator is 0.15pu. TX-1 is 0.075pu, T-Line is 0.092 pu and TX-2 is 0.1 pu. Total reactance is j0.417 pu. Base current is 0.6561kA. I am unable to get the same magnitudes as your answers. Please explain where I went wrong.

  • @halfengineer5
    @halfengineer5 3 роки тому

    since the per phase network diagram is considered why we take pu line voltage instead of pu phase voltage?

  • @mrafiziarazak6001
    @mrafiziarazak6001 2 роки тому

    What happen if the load has impedance value. Do we need to consider it for fault current calculation. Or we need to ignore it. Please help me clarify this.

  • @whynotruhi
    @whynotruhi 7 років тому +1

    great video. very clear and well explained. thanks

  • @EntertainingEyes
    @EntertainingEyes 6 років тому +1

    thank u so much sir I cleared all my doubts

  • @anthonybwalya4415
    @anthonybwalya4415 5 років тому

    extremely wonderful explanation

  • @vikaskumar-nq6yd
    @vikaskumar-nq6yd 6 років тому +1

    Well explained sir thanks for that ...can u do me a favour plse tell me plse how to record video using mobile means how to hold mobile or is there any holder available online if any please share link of. I will nmbe thankful to u .
    Thanks in advance.

  • @superpussycat6648
    @superpussycat6648 5 років тому

    Great representation Sir,congrats!

  • @irumsharaz6267
    @irumsharaz6267 5 років тому

    Great video

  • @bereketmolla4453
    @bereketmolla4453 5 років тому

    tnx sir you are a genious......I love this chapter after wathing this video.

  • @YahayaYakubu-v9b
    @YahayaYakubu-v9b Місяць тому

    thank for tutorials

  • @ramagiriprashanth049
    @ramagiriprashanth049 5 років тому

    Outstanding explanation tq very much sir👌👌👌

  • @johnpaulbruan4843
    @johnpaulbruan4843 4 роки тому

    for the transformer xpu, why solve twice, is it important to solve for both windings or just one winding is acceptable to get the value, I read some books that the kv new is the voltage in the second winding and the kv old is the voltage in the primary winding. it is confusing sir. thank you

  • @rupakkumarjha4954
    @rupakkumarjha4954 6 років тому

    Nice lecture.....Pls share information on instrument transformer saturation...

  • @MuhammadAhmed-zp8mi
    @MuhammadAhmed-zp8mi Рік тому

    Can you tell where can i find example where load is dynamic.

  • @velusamypothiraj2300
    @velusamypothiraj2300 4 роки тому

    How to find the old perunit reactances of equipment, and in case load is dynamic ex.motor, how to calculate the prefault. Voltage, generator voltage and fault current, explain with same diagram it will be very useful. And in case line to ground or L L G fault occurred how to calculate

  • @rvstalin43
    @rvstalin43 6 років тому

    Very good explanation..

  • @pushpakbhangale2689
    @pushpakbhangale2689 4 роки тому

    sir,
    from where you get the transmission line 100 MVA , 0.092 pu while calculating the Short Circuit Current

  • @ranjan1436
    @ranjan1436 5 років тому

    well explained, waiting to see more such videos from you.

  • @mahmodulhasan6116
    @mahmodulhasan6116 6 років тому

    VERY GOOD LECTURE... THANK YOU...

  • @lalashortwala31
    @lalashortwala31 6 років тому

    superb video sir...

  • @cedarxeda2665
    @cedarxeda2665 3 місяці тому

    How do you just select command base MVA? Can you select 50mva? Why 100MVA

  • @mohammedayaz9397
    @mohammedayaz9397 7 років тому

    sir please upload power system all lectures related to gate exam it will help us .. thank you so much..

  • @surendrakverma555
    @surendrakverma555 Рік тому

    Thanks Sir 🙏🙏🙏🙏🙏🙏🙏

  • @adembugra
    @adembugra 3 роки тому

    Hello teacher, I have a question about the power systems analysis course, can you help me?

  • @marcelogontinas8212
    @marcelogontinas8212 6 років тому +1

    Sir, can you recommend me a book for that lesson? Thank you.

  • @shubhambhandari415
    @shubhambhandari415 5 років тому

    Sir i have doubt what will we do if the hv, lv sidea of transformer is been given as star and delta.
    Please give me the ans as soon as possible

  • @sebastianshalet
    @sebastianshalet 2 роки тому

    Thanks

  • @safyan9442
    @safyan9442 6 років тому +1

    Thank you so much for this ❤️

  • @SHUBHAMYADAV-ex4zg
    @SHUBHAMYADAV-ex4zg 5 років тому

    In calculation of fault apprent power you say the voltage is equal to voltage at busbar 2 just before the fault at the time of fault the voltage is 22 kv but you write there is 1 how please solve my this problem

  • @ashiqueahmed9177
    @ashiqueahmed9177 6 років тому

    extrmly nice lecture

  • @jobinmathew6364
    @jobinmathew6364 7 років тому

    Great class sir.. u helped me.....

  • @tahmidchowdhury
    @tahmidchowdhury 5 років тому

    great video.

  • @sarigubonsri2091
    @sarigubonsri2091 7 років тому

    Thank you Sir for excellent lecture.

  • @sushmireddy2391
    @sushmireddy2391 5 років тому +1

    According to transform ratio 132÷11=12 ,how 132 has come in transmission line???

    • @Surajgupta-ym7uw
      @Surajgupta-ym7uw 5 років тому

      After multiplication of primary side voltage 11*12= 132

    • @SfisoRowen
      @SfisoRowen 5 років тому

      @@Surajgupta-ym7uw guptas destroyed south Africa

  • @sumanbastakoti9574
    @sumanbastakoti9574 6 років тому

    great job sir

  • @Rashed_007
    @Rashed_007 Рік тому

    Thanks...

  • @PrabhatKumar-zk8sp
    @PrabhatKumar-zk8sp 7 років тому

    sir all the video for learning concept sir please upload field theory video which is hard to understand

  • @nsakhalkar746
    @nsakhalkar746 6 років тому

    Very nice👍

  • @nikolaromanos456
    @nikolaromanos456 5 років тому

    well explained

  • @vaithiyanathanmanokaran449
    @vaithiyanathanmanokaran449 6 років тому

    Sir we are using only one transformer 11kv to 66 kv so how to calculate

  • @sandeepmalothvec4658
    @sandeepmalothvec4658 Рік тому

    thank you sir

  • @Muhammadumar-po1vx
    @Muhammadumar-po1vx 5 років тому +1

    which base power will be selected as base power out of T/Line ,T1 & T2 KVA ratings i.e 100 MVA,25MVA & 5MVA ? How did we select 100 MVA as base power

    • @MrSystemStatic
      @MrSystemStatic 5 років тому

      You can pick ANY number, it doesn't matter as long as it is consistently applied. Typically 100 MVA is used. But it also good convention to set Snom equal to the highest rated power of any equipment in the network.

    • @sampathkumarpatil6197
      @sampathkumarpatil6197 5 років тому

      yes, you can pick any number. But usually, we take the greatest MVA value in the given system.

  • @parth7450
    @parth7450 4 роки тому

    Which book question is this?

  • @lyuvaraj3544
    @lyuvaraj3544 5 років тому

    Super

  • @RakeshKumar-dy3lj
    @RakeshKumar-dy3lj 6 років тому

    Sir थ्री फैस बिजली के कनैक्शन में ampere से unit कैसे बनाए

  • @electricalpowerofengineeri9760

    👍

  • @junbaclay3871
    @junbaclay3871 7 років тому

    Thank you for sharing

  • @nasseralrahbi1626
    @nasseralrahbi1626 6 років тому

    thanks for this video

  • @dailyvlogs2873
    @dailyvlogs2873 6 років тому

    Its urgent sir plz make a video on LG fault ,L-L fault and LLG faults. Please it humble request.

  • @5amsquad778
    @5amsquad778 5 років тому

    Thank you

  • @reshmam6327
    @reshmam6327 6 років тому

    Sir how to calculate prefault voltage sir plz tell me

  • @vikramchaurasia3950
    @vikramchaurasia3950 6 років тому

    All douths clear

  • @pushpakbhangale2689
    @pushpakbhangale2689 5 років тому

    How did you get 100 MVA old as base power for transmission line

  • @vivekv8292
    @vivekv8292 5 років тому

    Please mention WHY choose 100mva as common base MVA.

    • @plaintechniques3075
      @plaintechniques3075 5 років тому

      You choose the highest MVA in the single line diagram because it is easier to work with. You can choose any logical value and follow the same procedure, the final short circuit should be the same.

  • @ravinarathod1164
    @ravinarathod1164 5 років тому

    Tq u sir

  • @ferdausahmad4193
    @ferdausahmad4193 5 років тому

    thanks bro

  • @moumitamondal5188
    @moumitamondal5188 6 років тому

    How synchronous motor feed the load(dynamic load) ?

  • @shahzadhashmi1454
    @shahzadhashmi1454 6 років тому

    👍👍👌👌

  • @ravinc527
    @ravinc527 6 років тому

    Why generator emf is assumed 1 pu ?

  • @sauravjain4890
    @sauravjain4890 7 років тому

    thank you sir for start making more videos.

  • @AryanRaj-id5hn
    @AryanRaj-id5hn 7 років тому

    Thank u...sir

  • @dilipsahusahu680
    @dilipsahusahu680 5 років тому

    Hindi sir please

  • @darkthoryt1054
    @darkthoryt1054 4 роки тому

    He video sir hindhi Karo

  • @soolkingalgerian6271
    @soolkingalgerian6271 5 років тому

    Thanks

  • @Checkmate6382
    @Checkmate6382 7 років тому

    thank you