QJ71PB93 Profibus DP Intelligent Module in mitsubishi melsec q series

Поділитися
Вставка
  • Опубліковано 3 гру 2024

КОМЕНТАРІ • 15

  • @zellerautomationandplc
    @zellerautomationandplc  Рік тому +2

    How to insert a Profibus DP Module QJ71PB93 into a System Q PLC form Mitsubishi using GXworks2

  • @renatetheresafigl5134
    @renatetheresafigl5134 Рік тому

    Thanks for sharing Gert, congrats, a great channel 🎉

  • @mdtarikulislam9328
    @mdtarikulislam9328 4 місяці тому

    I have installed gx works2 apps and gx configurator dp apps. But i didn’t' get profibus dp/dp module function in intelligent function. Sir please help me.

    • @zellerautomationandplc
      @zellerautomationandplc  4 місяці тому

      Hello Sir, i can not recall such a problem. Can you tell me the type of cpu you are using. Also the software version. I will check this woth the mitsubishi support.

    • @mdtarikulislam9328
      @mdtarikulislam9328 4 місяці тому

      @@zellerautomationandplc
      Good morning sir. Thank you sir for reply.
      GX Confugurator-DP Version 7.13P.
      GX Works2 Version 1.620W.
      PLC Cpu Q03UDV.

  • @TheCbr4446
    @TheCbr4446 Рік тому

    please make a video about melsec net configuration between master plc to slave plc. Also, how to move data from master plc to slave plc. plus, how file register is use in plc... thanks

    • @zellerautomationandplc
      @zellerautomationandplc  Рік тому +1

      Here you go
      ua-cam.com/video/A0KpLS9Tdj8/v-deo.html
      also have as look at this video: ua-cam.com/video/NhoI5CTcVwU/v-deo.html
      i think this may also be helpful for you.

    • @TheCbr4446
      @TheCbr4446 Рік тому

      ​@@zellerautomationandplcthank you sir

    • @zellerautomationandplc
      @zellerautomationandplc  Рік тому

      @@TheCbr4446 You are welcome. it is a pleasure to help.

  • @VivekTiwari-bh1ee
    @VivekTiwari-bh1ee Рік тому

    How to take profi bus module program back up

    • @zellerautomationandplc
      @zellerautomationandplc  Рік тому

      You want this back up from me?

    • @VivekTiwari-bh1ee
      @VivekTiwari-bh1ee Рік тому

      @@zellerautomationandplc
      Sir
      Already installed the module in our system, if existing module any trouble and I want to replace new module that time we have to download parameters on new module.

    • @zellerautomationandplc
      @zellerautomationandplc  Рік тому +1

      @@VivekTiwari-bh1ee Thats correct, because the parameters are in the module it self.