How to do 3 - Phase Motor Rewinding | 24 slots, Single layer, 2 pole | Motor Rewinding | Electrical

Поділитися
Вставка
  • Опубліковано 15 гру 2022
  • For online courses call : 9768871110
    Online Courses Android App: play.google.com/store/apps/de...
    Visit : www.pluspointonline.com
    Share, Support, Subscribe!!!
    Main UA-cam channel : / niketshahpluspoint
    Click for membership : / @niketshahplus
    Online Courses Android App: play.google.com/store/apps/de...
    Telegram : t.me/niketshahpluspoint
    Twitter: / niketshahplus
    Facebook: / pluspointtraining
    Facebook Myself: / niketshahkalyan
    Instagram: / pluspointtraining
    For Online Courses Website: www.pluspointonline.com
    Email: niketshah.pluspoint@gmail.com
    WhatsApp: +91 9768871110
    Online Courses also Available For more details Just call us on : 9768871110..
    About : Niket Shah Plus is a UA-cam Channel, where you will find technological videos in Hindi, Technology video on Electronics, Electrical, Computer Hardware Training, Laptop Repairing, Mobile Repairing, Circuit making, Computer Engineering Software Courses like AutoCAD, Animation, Video & Sound Editing, 3D animation, Microsoft Courses, Accounting Software and Many More.. Etc.. All In Hindi... thankx.. :)

КОМЕНТАРІ • 43

  • @fartadegovind3521
    @fartadegovind3521 Рік тому

    No 1 lecture sir👍

  • @emmanueltoke-jo3ms
    @emmanueltoke-jo3ms Рік тому +1

    I like it so much and I need more of it

  • @kishanpal8115
    @kishanpal8115 Рік тому +2

    Very good Sir my Kishan

  • @bacchokiduniyalive1396
    @bacchokiduniyalive1396 Рік тому

    Best knowledge

  • @nishukumar5911
    @nishukumar5911 Рік тому

    Very good sir

  • @Binodkumar-xz2zg
    @Binodkumar-xz2zg Рік тому

    Nice sir ❤️❤️

  • @ELECTRICTECH-mj9rz
    @ELECTRICTECH-mj9rz Рік тому +1

    Thanks sir

  • @kishanpal8115
    @kishanpal8115 Рік тому

    Bahut khoob Sir my Kishan

  • @mursedkhan3228
    @mursedkhan3228 9 місяців тому

    Thank you

  • @bluemorninggloryrose5489
    @bluemorninggloryrose5489 7 місяців тому

    Thanks bhaut khub

  • @bakhtmuhammadkhan2737
    @bakhtmuhammadkhan2737 Рік тому +1

    Sar stater wire ka formula kis Tarah nikal sakte hain please mere Sath town karo is per ek detail ke sath video bnao

  • @ImranKhan-tx4mb
    @ImranKhan-tx4mb 11 місяців тому +1

    Hii

  • @sonuprajapati4311
    @sonuprajapati4311 9 місяців тому

    3 phese 8.75 kva chain winding alternator ko single phase bana sakte hai kya. Agar ho sakta hai to batao bhai, Bharat industries ka hai , GNR

  • @musahebali4197
    @musahebali4197 9 місяців тому

    Sir kaise kneksan karte hai data chahiye dalta ka star delta ka three phase motor me

  • @sreejithns511
    @sreejithns511 Рік тому

    Name of winding method?
    Lap winding or chain winding?

  • @ToolsAandLogic
    @ToolsAandLogic 10 днів тому

    Please provide winding of dual voltage 3phase motor winding. Some motor manufacturers make dual voltage motor for North America market. For High voltage of 480 volt motor windings are connected in series and for Low voltage, 240 volt operation, windings are connected in parallel. Please provide winding details.

    • @NiketShahPlus
      @NiketShahPlus  9 днів тому

      Dual Voltage 3-Phase Motor Winding Configuration
      Dual voltage 3-phase motors are designed to operate at two different voltages by configuring the winding connections in either series or parallel. For high voltage operation (typically 480V), the windings are connected in series, while for low voltage operation (typically 240V), the windings are connected in parallel.
      Here's a detailed explanation of the winding configurations:
      Winding Configuration
      High Voltage (480V) Configuration (Series Connection):
      In this configuration, the motor windings are connected in series to handle the higher voltage.
      Each phase of the motor has two windings, which are connected end-to-end (series).
      Low Voltage (240V) Configuration (Parallel Connection):
      In this configuration, the motor windings are connected in parallel to handle the lower voltage.
      Each phase of the motor has two windings, which are connected side-by-side (parallel).
      Winding Details
      Terminal Connections for Dual Voltage Motor
      T1, T2, T3: These are the primary terminals for connecting the motor to the power supply.
      T4, T5, T6: These are the secondary terminals that are used to change the winding configuration.
      High Voltage (480V) Series Connection
      In this configuration, the windings are connected in series as follows:
      Connect T1 to one end of winding 1A.
      Connect the other end of winding 1A to one end of winding 1B.
      Connect the other end of winding 1B to T4 (Series Connection).
      Repeat for phases 2 and 3:
      Connect T2 to one end of winding 2A.
      Connect the other end of winding 2A to one end of winding 2B.
      Connect the other end of winding 2B to T5.
      Connect T3 to one end of winding 3A.
      Connect the other end of winding 3A to one end of winding 3B.
      Connect the other end of winding 3B to T6.
      Low Voltage (240V) Parallel Connection
      In this configuration, the windings are connected in parallel as follows:
      Connect T1 to one end of winding 1A and T4 (Parallel Connection).
      Connect the other end of winding 1A to one end of winding 1B.
      Connect the other end of winding 1B to T7.
      Repeat for phases 2 and 3:
      Connect T2 to one end of winding 2A and T5.
      Connect the other end of winding 2A to one end of winding 2B.
      Connect the other end of winding 2B to T8.
      Connect T3 to one end of winding 3A and T6.
      Connect the other end of winding 3A to one end of winding 3B.
      Connect the other end of winding 3B to T9.
      Summary of Terminal Connections
      High Voltage (480V) Series Connection
      T1 to T4
      T2 to T5
      T3 to T6
      Low Voltage (240V) Parallel Connection
      T1 to T4 and T7
      T2 to T5 and T8
      T3 to T6 and T9

  • @gangadharjadhav5800
    @gangadharjadhav5800 Рік тому

    🙏🙏

  • @shaileshjaiswar1654
    @shaileshjaiswar1654 Рік тому +1

    Sir video dekha dekha ke samjhaye

  • @technicalcrookedmind2102
    @technicalcrookedmind2102 Рік тому +1

    How are you all my friends

  • @muhammadasghar8098
    @muhammadasghar8098 2 місяці тому

    Sir , single layer aur double layer rewinding ki explanation Kren , double layer rewinding kyun ki jati hai aur kis motor main ki jati ?

  • @rajvishaltech.official13
    @rajvishaltech.official13 Рік тому +3

    आप तो बहुत बेहतर तरिके से समझा रहे हैं लेकिन सर मोटर पर भी समझायेंगे तो और भी बेहतर होगा

  • @technicalcrookedmind2102
    @technicalcrookedmind2102 Рік тому +1

    Hello friends mai hu SAMAR

  • @ronyrahmanronyrahman3471
    @ronyrahmanronyrahman3471 4 місяці тому

    Sir 24 slot 2pole 2leyer kaise kare

  • @rahinurislam2489
    @rahinurislam2489 Рік тому +1

    ☎️☎️☎️☎️☎️☎️☎️☎️☎️☎️☎️📞📞📞📞📞📞📞📞📞💓💓🌹🌹🌹👍👆👆👆👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍

  • @informationtechnology6349
    @informationtechnology6349 Рік тому +1

    Sir coil Span ka upar wala radius kaise nikale

  • @rahinurislam2489
    @rahinurislam2489 Рік тому +1

    👍👍👍👍👍👍💗💗🌹🌹🌹💓💓🌹🌹💗💗💗👍👍👆👍👍👍👍👍👍👍👍👍👍👍

  • @shaikmahboob889
    @shaikmahboob889 Рік тому

    Sir ,mujhe orient mini 20mm,stetor size ,24slots ,rewinding full speed data please reply

  • @vidhaykshingh1327
    @vidhaykshingh1327 Рік тому

    Plz share cooler winding

  • @kailashkumarmehta1467
    @kailashkumarmehta1467 Рік тому

    Practical motor mein banakar dikhaiye na ek bar

  • @Binodkumar-xz2zg
    @Binodkumar-xz2zg Рік тому

    Aaxese samjh aaya

  • @ferqurry8248
    @ferqurry8248 Рік тому

    Sir AP Ka number what's up pr Nahi a RHA

  • @kishanpal8115
    @kishanpal8115 Рік тому

    Very good Sir my Kishan

  • @ToolsAandLogic
    @ToolsAandLogic 10 днів тому

    Please provide winding of dual voltage 3phase motor winding. Some motor manufacturers make dual voltage motor for North America market. For High voltage of 480 volt motor windings are connected in series and for Low voltage, 240 volt operation, windings are connected in parallel. Please provide winding details.

    • @NiketShahPlus
      @NiketShahPlus  9 днів тому

      Dual Voltage 3-Phase Motor Winding Configuration
      Dual voltage 3-phase motors are designed to operate at two different voltages by configuring the winding connections in either series or parallel. For high voltage operation (typically 480V), the windings are connected in series, while for low voltage operation (typically 240V), the windings are connected in parallel.
      Here's a detailed explanation of the winding configurations:
      Winding Configuration
      High Voltage (480V) Configuration (Series Connection):
      In this configuration, the motor windings are connected in series to handle the higher voltage.
      Each phase of the motor has two windings, which are connected end-to-end (series).
      Low Voltage (240V) Configuration (Parallel Connection):
      In this configuration, the motor windings are connected in parallel to handle the lower voltage.
      Each phase of the motor has two windings, which are connected side-by-side (parallel).
      Winding Details
      Terminal Connections for Dual Voltage Motor
      T1, T2, T3: These are the primary terminals for connecting the motor to the power supply.
      T4, T5, T6: These are the secondary terminals that are used to change the winding configuration.
      High Voltage (480V) Series Connection
      In this configuration, the windings are connected in series as follows:
      Connect T1 to one end of winding 1A.
      Connect the other end of winding 1A to one end of winding 1B.
      Connect the other end of winding 1B to T4 (Series Connection).
      Repeat for phases 2 and 3:
      Connect T2 to one end of winding 2A.
      Connect the other end of winding 2A to one end of winding 2B.
      Connect the other end of winding 2B to T5.
      Connect T3 to one end of winding 3A.
      Connect the other end of winding 3A to one end of winding 3B.
      Connect the other end of winding 3B to T6.
      Low Voltage (240V) Parallel Connection
      In this configuration, the windings are connected in parallel as follows:
      Connect T1 to one end of winding 1A and T4 (Parallel Connection).
      Connect the other end of winding 1A to one end of winding 1B.
      Connect the other end of winding 1B to T7.
      Repeat for phases 2 and 3:
      Connect T2 to one end of winding 2A and T5.
      Connect the other end of winding 2A to one end of winding 2B.
      Connect the other end of winding 2B to T8.
      Connect T3 to one end of winding 3A and T6.
      Connect the other end of winding 3A to one end of winding 3B.
      Connect the other end of winding 3B to T9.
      Summary of Terminal Connections
      High Voltage (480V) Series Connection
      T1 to T4
      T2 to T5
      T3 to T6
      Low Voltage (240V) Parallel Connection
      T1 to T4 and T7
      T2 to T5 and T8
      T3 to T6 and T9

    • @ToolsAandLogic
      @ToolsAandLogic 9 днів тому

      @@NiketShahPlus thanks for reply. i want to know about winding digram. Does these low voltage and high voltage coils go in the same slot?