Moving Load: p7 - Interpret & Rectify Moving Load || Warning- Moving Load Applied Beyond X & Z Range

Поділитися
Вставка
  • Опубліковано 23 жов 2024
  • In this video, I will talk about a warning that is reported during moving load generation and discuss how to interpret this warning for further action.
    **WARNING-A MOVING LOAD THAT WOULD HAVE BEEN APPLIED BEYOND THE X AND Z RANGES
    OF THE STRUCTURE HAS BEEN IGNORED. CASE= 1 WHEEL 3 OF 6
    For any bridge or crane girder, load is applied on the structure from a moving vehicle and as location of the vehicle change over time, we need to find out the critical load position which provide maximum result. Though this seems like a complex process, STAAD is well capable of handling this type of load for analysis and there is a moving load feature available to generate all possible load condition.
    ****************************************************************************
    Steel Structure Optimization with STAAD -- • Steel Structure Optimi...
    Modelling, analysis and design of Pre Engineered Building -- • Modelling Analysis and...
    Implementation of IS800:2007 code in STAAD.Pro CONNECT Edition -- • IS800:2007 code implem...
    Design Automation with STAAD -- • Design Automation with...

КОМЕНТАРІ • 14

  • @hariprasathkumar1421
    @hariprasathkumar1421 Рік тому

    Please upload the video of other methods for applying horizontal loads on the crane girder.

  • @josephlucas4115
    @josephlucas4115 Рік тому

    When are you going to upload part 8?

  • @michaelloreantz
    @michaelloreantz 2 місяці тому

    Is it possible to envelope the results of moving loads then use the envelope in load combos for design?
    I do not see this to be possible in STAAD, and I do not see the use of the moving load feature if such combination/envelope procedure is not possible.

    • @surojit_ghosh
      @surojit_ghosh  2 місяці тому

      Partially yes, if you use other method of moving load generation rather than default feature. Check this video -- ua-cam.com/video/pHm5dNyFsZA/v-deo.html. If you follow this process to create moving load, it is possible to get a result envelope.

  • @salmanmhaskar6312
    @salmanmhaskar6312 2 роки тому

    Video on analysis result of Peb warehouse with eot crane...how to check or how the moving load acts on the structure and what varies

  • @josephlucas4115
    @josephlucas4115 2 роки тому

    Hello Surojit this week you did not post part 8

  • @salmanmhaskar6312
    @salmanmhaskar6312 Рік тому

    please upload part 8 with load combinations and other methods of applying horizontal loads

  • @prashantkumarjain905
    @prashantkumarjain905 2 роки тому

    Nice explanation

  • @Lee-cp9mc
    @Lee-cp9mc Рік тому

    Hi Sir, when can u upload P8 of moving load?

  • @Structure-Dubai
    @Structure-Dubai 9 місяців тому

    Hi surojeet, can you make a modeling video for moving load on ramp. Thanks

  • @rahulawasthi726
    @rahulawasthi726 Рік тому

    Hello sir, do you offer any paid course on staad pro?

  • @sunildhal7011
    @sunildhal7011 Рік тому

    Sir please make videos on rectangular,circular tank underground and over the ground .

  • @narayanmuduli6571
    @narayanmuduli6571 2 роки тому

    Sir can you make a model of Retaining wall and counterfort retaining wall in staad

  • @sunildhal7011
    @sunildhal7011 Рік тому

    Also retaining wall