Madali lang Naman yan sir, sakalin mo lang Yung oil inlet valve papunta mismong purifier or di kaya buksan until Yung recirculation line Ng feeding oil line nya. 😊
Do you have exp , when start 10 minutes all normal but when change to MM .. suddenly outlet pressure drop almost 0.002 so leaking … already overhoul and renew all o ring. My purif SJ10 Mitsubishi
If you put MM function to normal after you just started..it will alarm if the there is abrupt changes in oil temperature causing low back pressure. Try to observe the oil temperature until steady before putting MM function to normal.. Ang maintian back pressure to 0.150 average.. And the light should be steady at set temperature..hope might help this.
Nakadepnde po yan sir sa design Ng barko Nyo..may NGA design na NASA CRT na sya nakalagay..Meron Naman na NASA counter na sya.. if Wala ganun..NASA manual Ng purifier if panu icheck mga parameters nya sa loob Ng panel.. hehe
@@kiermiranda1239 very basic lng pag sumuka purifier..suction filter Muna linisan.. if malinis na..check mo if mag back to normal Ang parameters pag Hindi normal, adjust kana back pressure at temperature..dpat normal lahat..
Anu ibig mong sabihin sir? Pag Walang ilaw like Hindi umiilaw? Pag Hindi umiilaw, malayo sya sa range Ng normal parameter, abnormal alarm Ang next Nyan sa purifier..susuka sir.. at Yun ung ayaw natin..hehe
Specialist!! Thank you idol!!
You're welcome sir. Thank you for subscribing. Watch out for new videos to be uploaded soon. ☺️
galing mag explain dmi ko natutunan paps
Salamat idol..more vlogs to upload.
Salamat idol
Welcome idol..thanks for subscribing..more videos to upload..stay tuned!
Excellent ....
Thank you. Follow for more engineering contents.😊
Idol bossing paano naman po mag-adjust ng feedrate sa Alfa Laval na purifier? Thank you
@@iandenzelcacabilos2921 dagdagan mo lang opening Ng inlet valve papuntang purifier partner.
Can u put subtitles so that foreign audience can understand
Will put subtitles on our next upload..follow for more videos.. thank you for subscribing.
He just changover the suction filter into stand by filter and he adjust the temperature. Plus later on they will replace that suction filter.
Paano mag adjust feed rate
Madali lang Naman yan sir, sakalin mo lang Yung oil inlet valve papunta mismong purifier or di kaya buksan until Yung recirculation line Ng feeding oil line nya. 😊
Do you have exp , when start 10 minutes all normal but when change to MM .. suddenly outlet pressure drop almost 0.002 so leaking … already overhoul and renew all o ring. My purif SJ10 Mitsubishi
If you put MM function to normal after you just started..it will alarm if the there is abrupt changes in oil temperature causing low back pressure. Try to observe the oil temperature until steady before putting MM function to normal.. Ang maintian back pressure to 0.150 average.. And the light should be steady at set temperature..hope might help this.
paano po sir mag kuha ng running hours sa ganyan na model?
Nakadepnde po yan sir sa design Ng barko Nyo..may NGA design na NASA CRT na sya nakalagay..Meron Naman na NASA counter na sya.. if Wala ganun..NASA manual Ng purifier if panu icheck mga parameters nya sa loob Ng panel.. hehe
sir pano pag sumuka purifier anu ang gagawin nyan? anung mga i.aadjust nyan?
@@kiermiranda1239 very basic lng pag sumuka purifier..suction filter Muna linisan.. if malinis na..check mo if mag back to normal Ang parameters pag Hindi normal, adjust kana back pressure at temperature..dpat normal lahat..
paano kapag walang ilaw ang yellow light sa MM sir?
Anu ibig mong sabihin sir? Pag Walang ilaw like Hindi umiilaw? Pag Hindi umiilaw, malayo sya sa range Ng normal parameter, abnormal alarm Ang next Nyan sa purifier..susuka sir.. at Yun ung ayaw natin..hehe
ty sir gets kona po😘 normal na ng purifier ko jhehe.@@denyelangbatangmarino2178