  • @michaeljacosalem1129
    @michaeljacosalem1129 Рік тому

    Specialist!! Thank you idol!!

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  Рік тому

      You're welcome sir. Thank you for subscribing. Watch out for new videos to be uploaded soon. ☺️

  • @ruskeetuz9860
    @ruskeetuz9860 Рік тому

    galing mag explain dmi ko natutunan paps

  • @rockryanlague1951
    @rockryanlague1951 Рік тому

    Salamat idol

  • @fethiekitli4458
    @fethiekitli4458 Рік тому

    Excellent ....

  • @iandenzelcacabilos2921
    @iandenzelcacabilos2921 25 днів тому

    Idol bossing paano naman po mag-adjust ng feedrate sa Alfa Laval na purifier? Thank you

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  23 дні тому

      @@iandenzelcacabilos2921 dagdagan mo lang opening Ng inlet valve papuntang purifier partner.

  • @nairgopi6730
    @nairgopi6730 Рік тому +2

    Can u put subtitles so that foreign audience can understand

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  Рік тому

      Will put subtitles on our next upload..follow for more videos.. thank you for subscribing.

    • @pancitcanton6350
      @pancitcanton6350 11 місяців тому

      He just changover the suction filter into stand by filter and he adjust the temperature. Plus later on they will replace that suction filter.

  • @jackwarwinpalarpalar
    @jackwarwinpalarpalar 8 місяців тому

    Paano mag adjust feed rate

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  8 місяців тому

      Madali lang Naman yan sir, sakalin mo lang Yung oil inlet valve papunta mismong purifier or di kaya buksan until Yung recirculation line Ng feeding oil line nya. 😊

  • @nandasurya2120
    @nandasurya2120 8 місяців тому

    Do you have exp , when start 10 minutes all normal but when change to MM .. suddenly outlet pressure drop almost 0.002 so leaking … already overhoul and renew all o ring. My purif SJ10 Mitsubishi

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  8 місяців тому

      If you put MM function to normal after you just started..it will alarm if the there is abrupt changes in oil temperature causing low back pressure. Try to observe the oil temperature until steady before putting MM function to normal.. Ang maintian back pressure to 0.150 average.. And the light should be steady at set temperature..hope might help this.

  • @bryansayon2152
    @bryansayon2152 6 місяців тому

    paano po sir mag kuha ng running hours sa ganyan na model?

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  4 місяці тому

      Nakadepnde po yan sir sa design Ng barko Nyo..may NGA design na NASA CRT na sya nakalagay..Meron Naman na NASA counter na sya.. if Wala ganun..NASA manual Ng purifier if panu icheck mga parameters nya sa loob Ng panel.. hehe

  • @kiermiranda1239
    @kiermiranda1239 2 місяці тому

    sir pano pag sumuka purifier anu ang gagawin nyan? anung mga i.aadjust nyan?

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  Місяць тому

      @@kiermiranda1239 very basic lng pag sumuka purifier..suction filter Muna linisan.. if malinis na..check mo if mag back to normal Ang parameters pag Hindi normal, adjust kana back pressure at temperature..dpat normal lahat..

  • @markantelino1111
    @markantelino1111 3 місяці тому

    paano kapag walang ilaw ang yellow light sa MM sir?

    • @denyelangbatangmarino2178
      @denyelangbatangmarino2178  2 місяці тому

      Anu ibig mong sabihin sir? Pag Walang ilaw like Hindi umiilaw? Pag Hindi umiilaw, malayo sya sa range Ng normal parameter, abnormal alarm Ang next Nyan sa purifier..susuka sir.. at Yun ung ayaw natin..hehe

    • @markantelino1111
      @markantelino1111 2 місяці тому

      ty sir gets kona po😘 normal na ng purifier ko jhehe.​@@denyelangbatangmarino2178