HOW To flush a heating system with mains water easily!

Поділитися
Вставка
  • Опубліковано 12 гру 2024

КОМЕНТАРІ • 65

  • @petertapp1963
    @petertapp1963 10 місяців тому +12

    Just use flexible tap connectors to attach to the valves

    • @DGQ1Q2
      @DGQ1Q2 2 місяці тому

      mmm good idea

  • @tomsanders8714
    @tomsanders8714 9 місяців тому +4

    Ok never mind the comment on the shorts version of this. Fantastic idea. Going to flush my system like this

    • @mmplumber
      @mmplumber  9 місяців тому +1

      👊👊👊 good to keep the system clean

  • @davidgrainger-tm1ko
    @davidgrainger-tm1ko 4 дні тому

    yes , its what we did back in the day before power flush , i never power flush as it can cause more problems than solve ,so i put sentinal in first then thoroughflush the system as i can reverse each rad several times still a good vid for diyers but guys as said above dont put it through the boiler , good tip with the hose con i use them a lot

  • @Do_not_assume
    @Do_not_assume 7 місяців тому +4

    All that soldering. Just get two flexis, and 2 bits of copper pipe and attach the flexi to the lock shield valve. then attach the copper to the flexi, the other end of copper attach to hose pipe.
    job done.
    do this for both valves on the radiator side.

  • @marcusmaximus451
    @marcusmaximus451 3 дні тому

    Great vlog and excellent work kind regards Mark from Billericay 😃

  • @rudebwoy6570
    @rudebwoy6570 10 місяців тому +4

    I attach hose to a doc then put boiler in high rate , opem the doc and open the filling loop , watwr pumping round hot to free all that crao in rads and dumping thru doc , very affective and quick ! Add some mc5 before hand .

    • @Dylan-wo8yl
      @Dylan-wo8yl 4 місяці тому +2

      Does it not mean any of the crap from the radiators is flowing though the boilers heat exchanger ?

    • @andrewhayes4914
      @andrewhayes4914 3 дні тому

      Yes it would the only way to prevent that happening would be to fit a magnetic fillter on the return pipe work just before the boiler and I would themes a magnaclense dispatch all the magnatite

  • @777mjt
    @777mjt 2 місяці тому

    Add some X800 first & let it circulate for a couple of hours, then this method works a treat with improved results.
    Nice neat 10mm rad drops btw, hardly ever see microbore looking neat 🙂

  • @deniskundrat7161
    @deniskundrat7161 10 місяців тому +7

    Not sure how effective approach to flush the system would be by just opening a filling loop on boiler and flushing out through drainage valve under radiator ? This is a DIY man question, I might be missing something in my understanding. Thanks

    • @Baldylocks-w2j
      @Baldylocks-w2j 8 місяців тому +1

      It would be as effective as shown in the video. Mains flushing does have its place with cleaning out new installs or recent installs. I would say using a Kamco with appropriate chemicals is better for systems really sludged up - especially on microbore, the high flow and turbulence really dislodges all the shit.

    • @lewiscook431
      @lewiscook431 6 місяців тому +2

      Works an absolute treat mate. Continues water flowing through the system.

    • @LegendaryStee
      @LegendaryStee 4 місяці тому +1

      ​@lewiscook431 once you drained the system and all vent valves in rads are open would you need to close them again before opening the water valve?

    • @dgrose66
      @dgrose66 2 місяці тому

      @@LegendarySteepretty sure that you would

    • @dgrose66
      @dgrose66 2 місяці тому

      This is what I plan to do😊

  • @paulmurphy5396
    @paulmurphy5396 9 місяців тому

    Brilliant idea going to try it should I let it run through the boiler as well or just the system thanks 👍

  • @raulmartinezmoreno558
    @raulmartinezmoreno558 10 місяців тому +1

    Buen trabajo me podria decir que es la pasta blanca que le pone a las roscas gracias

  • @tomsanders8714
    @tomsanders8714 9 місяців тому +1

    Ok I do have a question about the parts. What is the male thread with the free nut called? Got everything else from my plumbers merchant but they don't know that. Thanks in anticipation and for all your vids.

    • @se9225
      @se9225 12 днів тому

      15mm Compression x 1/2" BSP Radiator Valve Tail (60mm Long) is premade and threaded... simply add the adaptor or jubilee clamp your tubing past the thread.. they around 6.99 each

  • @mickeyross108
    @mickeyross108 20 днів тому

    Great tip this quick question do I turn boiler off first and does the dirty water go through boiler..Keep up the great work 👏👏👏👍

  • @acurrentname
    @acurrentname 10 місяців тому

    Maybe you could use one of the top outlets on the radiator and then connect other hise to another radiator, closing one rad valve on each radiator, save taking radiator off? I have also wondered about using the filling loop under the boiler to flush system out? Anyway good video, thanks

  • @kingjaries
    @kingjaries 25 днів тому

    0 idea what happened but this was entertaining af for me lol

  • @KdeB
    @KdeB 8 місяців тому

    I have been meaning to text you for so long. This past year you have helped me so much. Your videos are as clear as crystal compared to lots og guys on here, Thank you so so much for everything you do and everything you teach, you are the ultimate tradesman. From and an Irishman in London. If you are ever in London, hit me up I owe you lots of beer.

  • @jaffplumbs26
    @jaffplumbs26 10 місяців тому +3

    Wouldn’t a non return valve instead of an isolation valve be better to prevent cross contamination? Great idea though I’m definitely giving this ago

    • @mmplumber
      @mmplumber  10 місяців тому +3

      Outside tap has one on the inside mate

    • @jaffplumbs26
      @jaffplumbs26 10 місяців тому

      @@mmplumber aw tidy 👍

  • @williamdgmartin
    @williamdgmartin 10 місяців тому +3

    Hi, what blow torch is that? Where did you get it? Thanks

    • @mmplumber
      @mmplumber  10 місяців тому +1

      Javac flexi torch

  • @techtinkerin
    @techtinkerin 10 місяців тому

    Easy if youre a qualified plumber with all the tools!😂 Nah just kidding, I used to see my dad and grandad doing something similar when I was a kid except they just filled it up from another tap near the header tank and drained it a few times. 😎👍

  • @pauldransfield9120
    @pauldransfield9120 Місяць тому

    How long did the whole process take? with how many rads?
    Thanks.

  • @talmanyurkovich4486
    @talmanyurkovich4486 5 місяців тому

    My hot water has stopped working and some of my radiators don’t heat at the top. I’ve tried to bleed them but some of them no air or water comes out. It’s an old system with no motorised valves and a header tank in the roofspace. I cleaned out the header tank as it was full of rusty crap. I want to try this flushing method but not sure how. And if the system is blocked or air locked will it even work?

  • @jameswright7375
    @jameswright7375 10 місяців тому +2

    Great idea.
    Quick question. Do you need to have the pump running at all, or just pet the mains pressure do all the work?

    • @wr3099
      @wr3099 10 місяців тому +1

      You don't want the pump running at all here. Probably do it damage it it was. Mains pressure is plenty to shift the crap

    • @davewright9312
      @davewright9312 4 місяці тому

      ​Mains pressure alone will only shift some of the crap.... When I had a recent boiler install the plumber did a power flush and as well as the power flush he used a type of rubber hammer in a sds drill to agitate all the crud in each rad.. The amount of stuff that came out was unbelievable... BTW many manufacturers insist on powerflush on new install to validate warranty​@@wr3099

  • @rustyshillford1967
    @rustyshillford1967 10 місяців тому +4

    What torch tip is that mate? I want one of those

    • @rayc1503
      @rayc1503 9 місяців тому

      Javac flexi torch and imho it's shite. Mine is bust after falling out my bag. It's a weak torch.

  • @MrMedicalUK
    @MrMedicalUK 3 місяці тому

    I like the kicks on the copper that how i do them
    More bends the better

  • @jodokast
    @jodokast 25 днів тому

    When you are flushing it does it run through the boiler itself

  • @b1h2u3p4
    @b1h2u3p4 10 місяців тому +2

    If open vent do you isolate vent and cold feed.

    • @mmplumber
      @mmplumber  10 місяців тому +4

      Cap off the vent and shut off cold feed or cut a valve in

  • @1stevew
    @1stevew 10 місяців тому +2

    Great video!!! Good use of the snazzy drain cock.... and very easy to send the water round in the other direction as well 👍

    • @mmplumber
      @mmplumber  10 місяців тому +2

      Yeah I did love them valves for quick connection

  • @TomTKK
    @TomTKK 10 місяців тому +1

    Bloody 'ell everyone's got a opinion or advice to share haven't they?
    You smashed it mate, not like you needed me to tell you that anyway 🍺

  • @wr3099
    @wr3099 10 місяців тому +2

    Good luck balancing those radiators again

    • @mmplumber
      @mmplumber  10 місяців тому +2

      Doesn’t take long

  • @littlejoeypeakdistrict7546
    @littlejoeypeakdistrict7546 8 місяців тому

    Dint mention a non return valve on feed pipe from the tap not very good if it ets into the main stream water

    • @dgrose66
      @dgrose66 2 місяці тому +2

      Your outside tap should have a double check valve for this very reason and be compliant with WRAS regs.

  • @p.c.c9290
    @p.c.c9290 9 місяців тому

    Trv needs a lock cap on otherwise they leak when removing rad .

    • @MagicDoughnut
      @MagicDoughnut 9 місяців тому

      No they won't. Will only leak if they have frost protection and the temperature will drop below 5 degrees C.

  • @tunnel7
    @tunnel7 9 місяців тому +2

    Why do they all use that gunge on compression joints it dont need it???

    • @mmplumber
      @mmplumber  9 місяців тому +3

      It does! I fix leaks daily on compression from people not using it

    • @martinwarner1178
      @martinwarner1178 9 місяців тому

      @@mmplumber Too true. I tried to tell people the same, then I saw their valves leaking....would they listen! No they know better. Good video, going to do mine the same, on old open vent system.

    • @grahamshillingford8229
      @grahamshillingford8229 9 місяців тому +1

      I have an open vented system, I thoroughly clean the header tank out first & I just attach a hose to one of the lowest rads & let the water out onto a drain & it just runs through until its clear I then switch to another downstairs rad & repeat & do this to all downstairs rads until they are all clear. I open each radiator up fully,one at a time, for 5 or 6 minutes as I go along. It drains faster than it fills so I syphon more water from the main water tank in the loft... no fancy tools needed. I'll be doing it again probably late March...

    • @mmplumber
      @mmplumber  9 місяців тому +2

      @@grahamshillingford8229 if you turn off the cold feed and cap off the vent you can do it this way. Your best to force it round a circuit to make sure it gets to all rads

  • @CaPiPwNsKi
    @CaPiPwNsKi 10 місяців тому +1

    Sweet

  • @mirola73
    @mirola73 16 днів тому

    No use if you don't have these things..............

  • @ricardoa.m1322
    @ricardoa.m1322 10 місяців тому +1

    Please stop driking water from heating circuit the last thing that we want it is that you get sick cause of that 🙏 about the powerflush you don't have a powerflush machine if you don't get yourself one straightaway cause they are simpñy brilliant no matter if its fernox,kamco,nostrom they all do the same exact job

    • @mmplumber
      @mmplumber  10 місяців тому +1

      Thanks for carrying and watching the video dude

    • @ricardoa.m1322
      @ricardoa.m1322 10 місяців тому +1

      @@mmplumber Thanks to you,they are so nice to watch sometimes I just watch your videos to relax that's how good they are ,but like I said before please do not drink heating circuit water even if it's pristine you are simply a topman I don't know even where did you get the time to edit and upload. Thank you so much for your splendid work and for your dedication 👍👌😊

    • @mmplumber
      @mmplumber  10 місяців тому

      @@ricardoa.m1322 really does mean a lot you like them mate is there anything you would like to see different? Are you happy the videos are in portrait?

    • @ricardoa.m1322
      @ricardoa.m1322 10 місяців тому

      @@mmplumber I like them so much cause you made things look much easier as they really are and not just that everything is so neat and clean and our job as you know is so dirty and messy. I like your videos cause you show your work but probably in the next future you will have to show yourself even that I think it's better to keep anonymity. Would be great also if you are doing some sealed system to show us,or some Air source or if you deal with HIU for example

  • @rzyrafa11
    @rzyrafa11 9 місяців тому

    all the crap i caused by radiators, should have let the water go through the whole system including radiators