घर का फाल्स सीलिंग करवाने की जरुरत नहीं | Ceiling Light Concealed Pipe work | Rate Analysis

Поділитися
Вставка
  • Опубліковано 23 лис 2024
  • n this video, we'll go over the process of installing a ceiling light concealed pipe work. We'll cover the basics of the process, as well as give you a review of the rate analysis.
    If you're looking to install a ceiling light concealed pipe work, then this video is for you! We'll go over the basics of the process and give you a review of the rate analysis. After watching this video, you'll be ready to start your installation!
    Your queries:-
    concealed light
    concealed light kaise lagaye
    profile light in ceiling
    ceiling light
    types of ceiling lights
    types of ceiling lights used in interiors
    led concealed light
    concealed light fitting
    led ceiling light
    concealed light box size
    best led ceiling panel light
    concealed light kaise lagaen
    false ceiling rate
    ledvance led panel ceiling lights
    concealed light connection
    syska false ceiling light installation
    motion detector sensor led ceiling lights
    Contact Details:-
    1. For Sponsorship and Business
    Deepak Kumar
    Mob: +91- 9523101369 (also WhatsApp)
    Email:- civilengineer.deepakkumar18@gmail.com
    My Social Network
    1. Facebook:- / civilengineerdeepakkumar
    2. Instagram:- / civilengineer.deepakkumar
    #FalseCeiling #CeilingLight #ProfileLight
    #civilengineerdeepakkumar
    #civilengineeringdeepakkumar
    #engineerdeepakkumar
    #erdeepakkumar
    #deepakcivilengineer
    #deepakkumarcivilengineer
    #civilengineer
    #civilengineering

КОМЕНТАРІ • 34

  • @dipak1978
    @dipak1978 Рік тому +1

    We r casting our slab... Wife talked about this trick, but I ignored as I didn't have idea. Thank you very much..... I'll certainly try this idea. 🙏🙏🙏

  • @munnababa834
    @munnababa834 Рік тому +4

    Engineer saheb Aap ke ye Tarika se maye confused Hu Chhat me pipe Aor holder wagera jitna Kam de chhat ke majbuti ke liye utna He Achha hota haye Ye Aap he Bataye haye,,ab chhat ki ceiling karne se Electric pipe Wagera Dena ki jarurat nahi padta wo electric pipe Wagera ciling ke upar open rahta haye,chhat majbut rahta haye Electric wire bhi kam lagta hai thoda kharch badhta haye ceiling karne me magar Sundar bhi dikhta haye Aor chhat majbut rahta hai

  • @mdilyasahmed4195
    @mdilyasahmed4195 Рік тому +1

    Sir slab par itney points laganey se kuch effect toh nhi hogana....

  • @NavnitKumarNavnit-q6e
    @NavnitKumarNavnit-q6e 10 місяців тому +1

    Sir chhat me pipe dal ka cerk aayega k nhi aayega btaye sir

  • @ghaint-deals6779
    @ghaint-deals6779 Рік тому

    Sir agar lanter 4.5 inch hae sukhne k baad,, tab bhi koi problem to nahi aegi ya aaegi

  • @salmankhan-oh1fp
    @salmankhan-oh1fp Рік тому

    Pup to tabh bhi karani padegi ya simple rahegi

  • @neerajjalal4478
    @neerajjalal4478 8 місяців тому

    Saste me ho jayega but.....ye leakage ka kaaran ban sakti hai ...slab 6inch honi chahiye. Or agar sirf dikhane k liye lagani h jalane k liye nai to na lagaye....🙏

  • @munnababa834
    @munnababa834 Рік тому +1

    Engineer saheb hamare yaha Abhi kuchh naye Ghar banaye ja rahe haye jo Ki Engineer plan se ban Rahe haye Ghar 600 sqft se1200 Sqft tak ke haye, Ab hamne Dekha ki 1200 Sqft me Aam Taor se 12 se 16 Column Lagte haye, magar waha 8 , se 10 Column Diye, Aor jaha jaha partition Diwal Aaye Plinth beam se beem connect karke Diwal utha liye,,, Hame ye baat Budhhimani wali laga,, Footing ka kharcha bacha,Kam column hone se ,, ye khrcha bacha lekin Udhar Column me reinforcement Badhaya Gaya,, hame ye pasand Aaya,, aap is Tarika par hame kuchh Achhchha Jaankari de,,

  • @NavnitKumarNavnit-q6e
    @NavnitKumarNavnit-q6e 10 місяців тому

    Sir chhat me concealed4 light pipe dal ne ka cerk nahi ayega sir btaye sir

  • @udayh9794
    @udayh9794 Рік тому

    Sir , does this plain electric wire concealed pipe have 100 percent bonding with concrete , as the steel have bonding with concrete , steel is not plain like plastic pipe , so plain pipe material may cause insufficient concrete bonding ?

  • @priyanshumusic8925
    @priyanshumusic8925 Рік тому

    Sir hamne bhi aise karwaya ek room me 4 conceal light diya hai..

  • @pankajmayawade529
    @pankajmayawade529 Рік тому

    Sir septic tank ka base column ki footing k upar sariya Dal kr banaya Hai
    Tank ko column ur footing se attach nhi Kiya Hai bt directly footing pr rakha Hai
    Is it okay

  • @bikashranjansethi6811
    @bikashranjansethi6811 Рік тому +1

    Sir dont you think it somwhow decrease the structurall benifits of slab.. and providing conceled box increase the posibility of leakage as it is taking almost 2.5" to 3"' of the slab.

    • @munnababa834
      @munnababa834 Рік тому +1

      Sahi kaha aapne ceiling karna Achha haye

    • @dipak1978
      @dipak1978 Рік тому +1

      Oh yes... I neglected this point 😮

    • @CivilEngineerDeepakKumar
      @CivilEngineerDeepakKumar  Рік тому

      Roof thickness jyada den

    • @munnababa834
      @munnababa834 Рік тому

      @@CivilEngineerDeepakKumar Engineer saheb Aap ke vedeo clip ham dhyan se Dekhte hai,,,,,,,roof thickness,,, 5,5, se jyada nahi karna haye, aur iske liye aap provide karte Hain 10mm reinforcement top or bottom donon aur Steel ka cover jo hai vah do SE dhai inch hona jaruri aur jo holder vagaira lagaenge vah 2 se 3 inch deep wale hote hai ab aap bataiye extra 3 inch roop ko Mota karna yani 7 to8 inch thickness rakhna padega ab bataiye aap iske liye reinforcement badhana padega 10 mm to 12 mm Aor jab roof ka reinforcement for thickness badhega to roof Ka beem aur colum Ka renforcement sab badhana padega akalmandi kis mein Hai engineer Sahab?

  • @civiltech1193
    @civiltech1193 Рік тому +1

    Thumbnail me jo ceiling pe shunk dikh rha hai upar ki or use kaise banayenge.. Aur shunkun bnane k liye plaster bhi krenge to utna mota plaster kaise hoga...

  • @dipak1978
    @dipak1978 Рік тому +1

    But is it ok from structural strength point of view??

  • @sujit_sahoo
    @sujit_sahoo Рік тому

    Me recently 1900 sqft ka celling lights lagaya hu. 3000rs metarial laga

  • @YouTubecivilsite
    @YouTubecivilsite Рік тому

    Sir ham 600 feet lamba boundry wall bana rahe hai boundry wall ko sitha ek line me karne ke liye koi asan tarika batao

  • @govindaagrawal2157
    @govindaagrawal2157 Рік тому

    Iske baad light wiring wala kitna cost lega per light

  • @yrcryptoguy
    @yrcryptoguy Рік тому

    don't do this you have to give lots of points for light and fan this will weaken you slab plus you can get any design with this it will be simple