@@lohisya_media I worked as a MEP senior technician at Phoenix mall (2017 to 2019) Interview Questions 01)what's is distribution transformer 1 Ena readings note panuvinga?How many hours once 2 Ena ena protection device iruku transformer la? 3 what's breather ? 4 what's Buchholz relay? 5 What is Power factor and why using capacitor bank? 6) What's maximum demond ? 7) Tab changing process? types of tap changing in transformer? 8) tell about electrical sub station in commercial building? 9) electrical meter reading epdi note panuvinga? 10) tell about ACB and VcB 11) tell difference between MCB ,Mccb ,Rccb,Mpcb 12) Draw star delta starter control diagram 13) Draw 2 way switch diagram 14 ) draw dol starter connection 15) What's is ppm ? electrical pannels and DB ppm la ena parameters note panuvinga and why need to do ppm? 02) Diesel generator 1) tell about DG 2) what's A,b,c,d check 3) what parameters noted in DG 4) Maximum evalo load la run panalam? 5) Why using cooling tower for DG and cooling tower maintenance 6) 1kwh ku evalo diesel consumption agum? 03) HVAC 1 what's is chiller and types and gas type 2 chiller parameters 3) what's primary and secondary and condensor pump 4) explain refregrent cycle 5) why using cooling tower for chiller 6) cooling tower maintenance 7)explain AHU ,FAhu,CSU , 8)How to calculate CFM? 9) AHU ppm ? 04) water treatment process and STP 1) explain water treatment process 2) Explain stp process 5) BMS syestem 1) tell about bms and advantages 6) Fire fighting syestem and fire alaram system 1) tell about fire fighting system 2) tell about fire dril 3) Tell about fire alarm system logics
Hi bro ..I have a one dough...we are using air cooled chiller in our factory.. already we are supplying the cooled air inside the factory by AHUs..but same time HVLS HIGH VOLUME ceiling fans also running..is affect the cooling efficiency inside factory?
Bro nalla panringa.hvac software related Q&A interview pathi solunga
Nice bro...keep doing informative videos
Thank you so much for uploading this video sir👌👌👌👌I worked at phoenix mall 2 years before Sir(FYI)
Share your interview questions bro I will share with our UA-cam friends
@@lohisya_media I worked as a MEP senior technician at Phoenix mall (2017 to 2019)
Interview Questions
01)what's is distribution transformer
1 Ena readings note panuvinga?How many hours once
2 Ena ena protection device iruku transformer la?
3 what's breather ?
4 what's Buchholz relay?
5 What is Power factor and why using capacitor bank?
6) What's maximum demond ?
7) Tab changing process? types of tap changing in transformer?
8) tell about electrical sub station in commercial building?
9) electrical meter reading epdi note panuvinga?
10) tell about ACB and VcB
11) tell difference between MCB ,Mccb ,Rccb,Mpcb
12) Draw star delta starter control diagram
13) Draw 2 way switch diagram
14 ) draw dol starter connection
15) What's is ppm ? electrical pannels and DB ppm la ena parameters note panuvinga
and why need to do ppm?
02) Diesel generator
1) tell about DG
2) what's A,b,c,d check
3) what parameters noted in DG
4) Maximum evalo load la run panalam?
5) Why using cooling tower for DG and cooling tower maintenance
6) 1kwh ku evalo diesel consumption agum?
03) HVAC
1 what's is chiller and types and gas type
2 chiller parameters
3) what's primary and secondary and condensor pump
4) explain refregrent cycle
5) why using cooling tower for chiller
6) cooling tower maintenance
7)explain AHU ,FAhu,CSU ,
8)How to calculate CFM?
9) AHU ppm ?
04) water treatment process and STP
1) explain water treatment process
2) Explain stp process
5) BMS syestem
1) tell about bms and advantages
6) Fire fighting syestem and fire alaram system
1) tell about fire fighting system
2) tell about fire dril
3) Tell about fire alarm system logics
@@nanthakumar4930 nice bro
hie bro can i get your contact no
@@mkamaludeen4 check my channel bro its available
Excellent explanation
Hello sir,I'm completed in HVAC design and drafting but I can't understand in design?
HVAC water consumption full length vedio podunga
03:30 to 03:50 sec , chemical oda names and uses pathi dedicated ha oru video podunga ji....
Bro Cooling tower water treatment video iruku bro adhulay clear ah soliirupayn
Hi bro maximo operation pathi solluga
Mechanical engineer ku adhu use aguma
Sir pls voice is not clear
VFD pathi oru detailed video podunga ji
Video iruku bro
What is CBRE full explain please
Coldwell bankers Richard Ellis
Qualification and interview questions pathi sollunga
Bro nalla soldrinka but important vishayaththai sollumpothu enakku puriyamattinkuthu
Thanks sir
Sir can you guide me how to prepare a good resume for Hvac Er
Building management system interview questions solunga brother
Very useful brother
ATS pathi vedio podunga sir
Which ATS bro there are many ATS
Arrow water 🤔🤔means
Btu meter working video sir
Please make in English also
Hi bro ..I have a one dough...we are using air cooled chiller in our factory.. already we are supplying the cooled air inside the factory by AHUs..but same time HVLS HIGH VOLUME ceiling fans also running..is affect the cooling efficiency inside factory?
No bro it will not effect the cooling system HVLS fans rotate with 2 to 3 mph which will give effective air cooling it will combined with HVAC
@@lohisya_media ok bro .. thank you 🙏
@@vadivelrock8839 bro HVAC vacancy irundha sollunga bro
Energy costing panunga bro
உங்கள பத்தி சொல்லுங்க ணா, எங்க வேலை பன்றீங்க ? எங்க இருக்கீங்க ?
Tvs training and services and chennai
Thank u sir,,, sir I am from srilanka,,
Plz discribe BMS system,, I will waiting 🌝🌝🌝🌝
Sir na unga assistant ah varen sir
☺️
Sir can you translate in telugu
English pls