1st you Press Red button after that push Green button and check with Step up or Step down the voltage, if it trip again , there can be problem in Motor, you need to check motor terminal .
Sir Good afternoon oltc transformet ki green switch baaher hi. Aur red switch bhi bahar hi. Wo auto aur manual kaam nahi kar raha hi. Green, red switch sey smok aa rahaa hai. Qey karna hi. Pl Help.
1 baar Wire check kr lo Green aur Red Switch k pass.. Koi Wire loose to nhi hai. Agr loose hai to tight kr do. Aur agar thik hai to 1 baar green Switch ko ON krke check kro..
Hi sir mera oltc automatic tap change nhi ho raha hai or din me voltage sahi rehta hai or rat me voltage 452 tak aa raha hai bahut presan hu sir kaise krege reply kijiye sir please
I thik 415 V coil hogi .. Contractor k upar likha hota hai coil 220 V hai ya 415 V.. ya fir aapke pass multi Meter hai to A1 and A2 Terminal pr Ac Voltage check lo.
Kbhi Kaabar Aisa bhi hota hai ki Contactor heat hokar chipak jaate hai jisse Tape Regulator Change hota rehta hai .. Agar Contactor thik hai to fir control Wiring me Problem hai
1 baar Manual me krke lower pr krke check kro. Tap change ho rha hai ya nhi. Agar nhi ho rha to OLTC me Lower ko jo command deti hai us contactor me problem hai.
Pehle wale Comment pr reply kr diya hai maine..DSS Switch Check karo. Is Video ko dekhkr thik kr do 👇 ua-cam.com/video/2FvBVdvMbRU/v-deo.htmlsi=JW3CkxnDKvLUy5kh
ये कैसा video बनाया भाई, ये तो आपको पता था, green OFF है, उसको press करके RTCC पैनल ठीक हो गया, कल एक MCB को भी गिरा कर video बना सकते हो, परसों कुछ और को OFF करके video बना सकते हो, आपने ये कहा बताया कि green कैसे off हुआ और उसको कैसे tress करना है,
ये तो आपने, green bottom को reset कर दिए, जिससे RTCC panel work करने लगा, पर आपने ये कहा बताए कि, उस probelm तक कैसे पहुंचा जाए, ये green bottom, किस condition में off हो सकता है और आपको ये बताना चाहिए था कि वह green bottom का नाम क्या है, और वह किसलिए use होता है,
THANK YOU SIR APKA VEDIO DEKHKAR TRY KIYA TO HAMARA 5 MVA P.T/F KA HI SAME PROBLEM THA O SALVE HO GYA .
Waah kya Baat Hai.. Gud 👌👌
DP MCB TRIP HO RHI HAI KYA KRE
Tape Change hote huye trip ho raha hai to motor me problem hai
Sir can we do tap changing while power is on.. Koe issue to nhii hoga na..?
Yes, you can change the Tap without off Main Supply in case of OLTC.
Sir Mujhe apko video bhejna hea taaki aap mere OLTC ko dekh kar bta sake ki uski kia issue hea..
Ok aap mujhe instagram pr send kro.. About me link h
Bhej do bhai video
The green push button is tripping after making ON. pl advice.
1st you Press Red button after that push Green button and check with Step up or Step down the voltage, if it trip again , there can be problem in Motor, you need to check motor terminal .
Sir Tap Position indicator ke digit or CTR ke digit change hai Kaise equal Karen
Sir maine ye kbhi kiya nahi hai to mujhe iska idea nahi hai.. Aapka koi vendor ho jo RTCC panel dekhta hoga wo hi isko Set kr dega.
423or 424 no wire par Kam nahi kar raha hai 223'224 par par Kam kar raha hai kya fault hai
Sir muze CTR Make OLTC ki puri control wiring samzna hai... Please aap video banado.
Actually Wiring to mujhe bhi nahi aati.. Fir bhi mai 1 baar Wiring Samajhne ki koshish karunga.. Agar Possible hoga to video bhi bana dunga.
@@TechnicalWork1 ok. Please. If possible.
Ok Sure 😊
Manual operation with handle
Good topic
👍
Thanks 👍
😊🙏
Thank you its work
Sir Good afternoon oltc transformet ki green switch baaher hi. Aur red switch bhi bahar hi. Wo auto aur manual kaam nahi kar raha hi. Green, red switch sey smok aa rahaa hai. Qey karna hi. Pl Help.
1 baar Wire check kr lo Green aur Red Switch k pass.. Koi Wire loose to nhi hai. Agr loose hai to tight kr do. Aur agar thik hai to 1 baar green Switch ko ON krke check kro..
Hi sir mera oltc automatic tap change nhi ho raha hai or din me voltage sahi rehta hai or rat me voltage 452 tak aa raha hai bahut presan hu sir kaise krege reply kijiye sir please
Rtcc Panel se Manual me Work kr raha hai kya
Avr relay main pt uv fult a Raha hai.kaise thik kare sir
Dear
Transformer m RTC panl manual krte RTC panl relay off ho ja rhi hai
Rtcc panel se Manual me Tap change ho rha hai ya nhi?
Agar contector kharab h to contector ko coil power kitna hota h 🙏
Bataya nhi sir
@anilsahu9330 actually ab free hua hu mai
I thik 415 V coil hogi .. Contractor k upar likha hota hai coil 220 V hai ya 415 V.. ya fir aapke pass multi Meter hai to A1 and A2 Terminal pr Ac Voltage check lo.
Green button come out after pushing it autometically.
Tap 6 and indicon 7
Motor is stucked warning what is the problem
1 baar motor k Terminal check karo kahi koi Wire heat to nhi hai.
Hamara jo oltc he work nahi kar raha he to kya kare
Manual me bhi tap change nhi ho rha?
Sir rtcc panel me hamara oltc manuali oprate ho raha hai but remote me nahi ho raha hai
Ise kaise thik kare
Kb se Problem Aa rahi hai
Last one month se
1 baar mujhe Rtcc panel ki pic send krna meri Instagram i'd pr.. Fir dekh k btata hu.
Instagram I'd ka link About me hai
Sir drawing melegi eski
Abhi to nahi hai mere pass.. Kal mai 1 baar check krke btata hu.. Agar mil gyi to mai send kr dunga
@@TechnicalWork1 thank you sir
Hello sir auto me rakhne pr tape increase ho jate h and motor continue running me rahti h aur manual me voltage low ho jata h please help
1 baar OLTC me jo control Wiring hai uske saath me Jo MCB lagi hai Use off krke 1 baar Check Karo Contactor hold to nahi ho rkha hai
@@TechnicalWork1 contector hold ho jata h jisse tape increase hote rhte h
Kbhi Kaabar Aisa bhi hota hai ki Contactor heat hokar chipak jaate hai jisse Tape Regulator Change hota rehta hai .. Agar Contactor thik hai to fir control Wiring me Problem hai
@@TechnicalWork1 kya contector change kr dekh sakte h agar hold ho rha h to contector essu nhi to controll wiring problem
Nhi 1 baar aap oltc ki Jo control Wiring hai uski Supply ko off krke Check karo koi sa bhi Contactor hold nhi hona chahiye Supply off hone k baad
भाई आटो में काम नही कर रहा है और वोल्टेज up and डाउन हो रहा है
प्लेसी टेल me ब्रो
Rtcc panel se Manual me Tap Change ho raha hai ya nhi.
Control panel 66 kv voltage meter nhi chl raha
Uske fuse nikale hai
Jab fuse lagate hai to common dc fail ka indication ata hai ye kya problem huye
Remot par tap bada raha h but kam nahi ho rahay h
1 baar Manual me krke lower pr krke check kro. Tap change ho rha hai ya nhi. Agar nhi ho rha to OLTC me Lower ko jo command deti hai us contactor me problem hai.
Bar bar up down har 10secnd me to kya kare
AVR Relay me problem hai jiski wajah se baar baar Tap change ho raha hai.
2 rtcc panal parelal canection
2 RTCC Panel hai Apke Yaha
ua-cam.com/video/CqWrxJ___MQ/v-deo.html
ua-cam.com/channels/Xr8zgeZ4Nzy9eDYgRKyPGw.html
Auto me kam nhi kr rha hai
Jaisa maine Video me btaya hai waise krke Check kro
Auto me work nahi karta hai
Rtcc panel se Manual me work kar raha hai?
Continuoue burger baj raha hai
Pehle wale Comment pr reply kr diya hai maine..DSS Switch Check karo.
Is Video ko dekhkr thik kr do
👇
ua-cam.com/video/2FvBVdvMbRU/v-deo.htmlsi=JW3CkxnDKvLUy5kh
Sir hamare oltc me tap change ki comand jati hai tab o khat khat ki awaj aati hai continue but tap change nahi hota hai
Auto me hai ya Manual Operate karte ho..
ua-cam.com/video/CqWrxJ___MQ/v-deo.html
ua-cam.com/channels/Xr8zgeZ4Nzy9eDYgRKyPGw.html
OLTC me jo 3 phase power aa raha hai usaka phase sequence change kre ho jayega
ये कैसा video बनाया भाई, ये तो आपको पता था, green OFF है, उसको press करके RTCC पैनल ठीक हो गया,
कल एक MCB को भी गिरा कर video बना सकते हो,
परसों कुछ और को OFF करके video बना सकते हो,
आपने ये कहा बताया कि green कैसे off हुआ और उसको कैसे tress करना है,
Bhai Maine isi problem ko Smjhane k liye ye Video banaya hai.
ये तो आपने, green bottom को reset कर दिए, जिससे RTCC panel work करने लगा, पर आपने ये कहा बताए कि,
उस probelm तक कैसे पहुंचा जाए, ये green bottom, किस condition में off हो सकता है
और आपको ये बताना चाहिए था कि वह green bottom का नाम क्या है, और वह किसलिए use होता है,
Aapna number do bhai
Oltc automatic tap change nhi ho raha hai or rat me voltage badh jata hai please sir reply kijiye
Rtcc panel se Manual me Tap Change ho raha hai kya
Ha
Manual ho raha hai auto me nhi change over ho raha hai
Or abhi dekhiye sam huwa hai voltage badhna chalu ho gya hai
Rat me 12 bje tak 452 tak voltage badh jata hai