Float Switch wiring and diagram with magnetic contactor | water level switch | water pump control
Вставка
- Опубліковано 4 жов 2024
- Wiring and diagram for a Float Switch (water level switch) for water pump control in tagalog | Local Electrician
#floatswitch
Thank you for watching guys!
Please visit our Channel👇👇👇
/ @localelectricianph
for more electrical installation and controls video tutorials.
FB Page: Electricians Guide
Direct message on our FB page for other questions. Thanks!!
OTHER USEFUL VIDEOS 👇
MANUAL OFF AUTO Motor Control with Selector Switch
• MANUAL-OFF-AUTO Motor ...
3GANG SWITCH wiring
• 3 Gang Switch Wiring t...
HOW TO USE MEGGER / insulation tester
• HOW to use MEGGER Insu...
3-WAY SWITCH Wiring Tutorial
• 3 Way Switch - tagalog...
WYE DELTA MOTOR CONTROL
• WYE DELTA STARTER Wiri...
Stop Start Wiring Control Circuit and Diagram
• Stop Start Magnetic Co...
FORWARD REVERSE STEP BY STEP
• FORWARD REVERSE Motor ...
On Delay Timer Wiring Diagram
• ON Delay Timer Diagram...
FLOATLESS RELAY WIRING
• Floatless Relay Wiring...
Stop Start with Overload Relay Connection
• Magnetic Contactor Sto...
• Overload Relay ( therm...
OVERLOAD RELAY Function tutorials. tagalog
OHMS LAW
• OHMS LAW - Voltage Cur...
24 HOUR TIMER FUNCTIONS
• HOW TO SET 24 HOUR CLO...
• Multimeter Paano guma...
How to use MULTIMETER tagalog video
STOP START w/ INDICATOR LAMP
• STOP START w/ INDICATO...
• HOW TO SPLICE A WIRE -...
How to Splice a Wire video
MAGNETIC CONTACTOR PARTS AND FUNCTIONS
• Magnetic Contactor Par...
VOLTAGE TESTER
• VOLTAGE TESTER NEON SC...
HOW TO COMPUTE ELECTRIC BILL
• Electric Bill Computat...
7 WAYS TO REDUCE ELECTRIC BILL
• HOW TO LOWER ELECTRICI...
POWER FORMULA
• POWER CURRENT VOLTAGE ...
HOUSE WIRING TUTORIAL
• HOUSE WIRING TUTORIAL-...
PHOTOCELL with Magnetic Contactor
Wiring/Diagram-street lights
• PHOTOCELL w/ Magnetic ...
Magnetic Contactor VS Mechanical Relay
Uses and Function
• Magnetic Contactor VS ...
SUBMETER INSTALLATION
• SUBMETER INSTALLATION ...
MECHANICAL RELAY WIRING
• RELAY WIRING TUTORIAL ...
Music:
Tuff Data | Vans in Japan
No Copyright claim.
• Video
Pangmatagalang Float Switch mga Master shope.ee/3AXTvOWobZ
¹ok
Boss salamat sa pag sagot...
Welcome po
Finally!!! After watching 20 videos without success someone finally shows the correct way to tie the floaters and I did not know about the orange cap opening for water in the floaters!!!
Thanks a lot!!!
Good to hear that Sir.🙂
they are for filling water into them and seal them
Maraming salamat sir... Napakaditalyado NG vedeo tutorial mo...👍👏👏👏
Welcome po sir.
Sir sa floater pwe d ba mag dala Ng live sa floar
Pwedi po..kasi f floater.hindi naman po mababasa ang wire nyan...
Sir gud pm po. Pwedi po ba makahingi ng diagram nyo sorry dko kasi makita yang mga connection jaan sa contactor mo.
Pa message po sa fb page natin Sir
Waching from taiwan,salamat sa info....malaking bagay to sa mga kagaya q na baguhan...mabuhay po kau
Salamat dn po.. ingat po
yan ang gusto malaman. motor control. 4ward to reverse. tnx po
Welcome po
Thank u sa tuitorial Sir...GOD BLESS.
Thank you sir.
thanks po sa patuloy na pagtulong sa amin
Salamat dn po
Wow start and stop diagram kalimitan iyan ang gamit sa bahay mostly kahit sa mga stablishmento
Puno ang tank at mag stop pag low ang tubig
Mag sip2x ung motor pag reverse cycle meron po ba
Napakalinaw sir salamat poh
Salamat po
Boss, ask lng kailangan ba dumaan ng magnetic contactor? ano disadvantage if direct to motor na yung float switch, thenk you po.
For signal switching lng dapat amg float switch..mababa ang switching capacity nya lalo sa malalaking motor..contactor have high ampacity and also thermal overload protection
Salamat idol malaki g sa aming mga bagong gumawa NG control panel huag ka Sana magsawa
❤
Excellent tutorial bro
Thank you po sir sa panonood
Thanks sa information
Welcome po
good tutorial master sir
Salamat po
Thank you master.🙏
Welcome po
Thanks lods sa knowledge
Welcome po
Very good idol 👍
Salamat po
Salamat master
Welcome po
well explained
Thank you po
Sir husay anh mgs vedeo mo shuot po dyan taga cebu po sko bisaya..
Thank you po
Salamat boss.
Welcome po
ayos kaayo bai
Salamat bai..
exellent.ty
❤️❤️
Salamat master p shout out
Thank you dn po
Nice idol ..
Salamat po
salamuch sir
Salamat dn po
Salamat pO👍
Your welcome po
Sir napanood ko yung katulad ng video mo rekta yung float switch sa motor ng water pump...sayo may magnetic contactor ano po ba mangyayari pag walang contactor
Pag maliit na pump lng sir. Pwedi naman walang contactor. Gamit ka lng ng thermal circuit breaker. Pero f malaking pump.daoat may contactor at overload relay na po
@@LocalElectricianPH sir yung motor pump namin 3/4 hp pagpindot ko ng switch umugong lang hindi umikot off ko agad dinala ko sa repair shop pinalitan lang ng starter capacitor umandàr na...
Pag nilagyan ko ng float switch automatic na sya mag start hindi ko na mababantayan kung umuugong lang yung motor at hindi imiikot ano ba pede ikabit para mag off yung kuryente pag hindi umiikot yung motor at umuugong lang halimbawa nasira ulit yung starter capacitor para maiwasan masunog ang motor...
Magnetic contactor at overload relay sir
Nice vedio
Sir 2 floating switch naman po sana.
Salamat
Ok po Sir...bili muna ako gamit po..medyo mahal kasi😅
Galing mu boss
Salamat po
Sakto boss mgkakabit ako floater switch bukas Wala ako idea e building electrician KC ako wla ako ganu Alam sa control.
Goodluck sir
gud day sir, pwede lng po ba na hindi
gamitan ng m-contactor yung float switch? e recta nlng yung float switch sa motor power supply para ma cut yung power...submersible water pump gamit...
Pwedi naman po basta yang malilit na pump sir. Gamit ka lng ng thermal circuit breaker
Sir sa 1.5hp ba motor, ilang amperes po na MC at OL ang kailanagn gamitin, for deepwell po?
25A MC. O.L 8 to 10
Maraming salamat sir npakalinaw na vlog, sir tanong ko lng pwde b gumamit ntong float switch direct lng sa CB wala ng Magnetic Contactor?
Pwedi naman po sa maliliit na motor kaso walang thermal overload protection. Nasa sa inyo napo yun Sir.
@@LocalElectricianPH salamat sir, ganun pla, maliit lng dn kc motor ko, 0.75 hp lng.
Ahh ok po. Meron dn po nabibili na thermal protected circuit breaker na pang motor..recta na rin po sya
@@LocalElectricianPH may link kyo online sir, kung san mkabili nyan?
Marami po sa lazada or shopee Sir. Search nyo lng po..wala dn kasi ako nyan.balak ko palang bumili
Sir same lng po ba ng wiring kpag sa sump wiring nyo po ikakabit ung sakin po kasi kpag ubos na ang laman ng tank ska po siya mag automatic off po ung pump po bale po ba ang pinkaiba lng po ay dun sa sump wala na po iba gagayahin ko nlng po ung digram nyo tama po ba hingi lng po ng idea salamat po
Same diagram pero ang float switch nyo ay e connect nyo sa normally close..
sir request po kong paano mag wiring sa APC AUTOMATIC PUMP CONTROL na may float switch
Pki check po if ganito ba sir? ua-cam.com/video/ycYlqv5jZXI/v-deo.html
Nice boss
Salamat Sir
Sir good day .. my video link po kayo ng how to determine normaly close & normaly open in magnetic contactor..
Salamat po sir..
Normally Close po nakalagay yan NC normally open NO meron tayo links sa channel playlist po mga motor controls ang testing ng contactor..marami po sir pki visit lng
Hi sir. Pwde po ba malaman kung anong gnamit nyo na magnetic contactor dito? Or kung pwde po send ng link ng lazada. Thanks po and more power po sa inyo. Very helpfull po mga videos nyo.
Search nyo lng po magnetic contactor Sir sa shopee or lazada. Tag 500 ko yan nabili yung kulay blue ko...pero yang fuji sa video 1300 po
Pwede bang directa na sa .5hp motor wala ng contactor? Thx.
Gamitan nyo po neto Sir recta napo yan. 4 to 6A ang orderin nyo shope.ee/6fBTlwOvYc
D2 sa UK, hindi n gngamitan Ng electrical,floaters LNG n on/off may valve n pag tinaas ng tubig ung floaters kosa n syang hihinto dahil mg ooff or mgsasara yong pinaka gate nyn parang s gate valve
Salamat sa inputs Sir
Boss panu pag Ang gamit ko is 12v lng n submersible pump kelangan paba Ng magnetic contactor
Yes Sir. Meron dn 12 c magnetic contactor.. pwedi sn naman recta gahana naman.kaso protection kasi yan sa motor natin. Pero nasa sau parin yan f gagamitan nyo po. Ilang watts po na yan Sir?
Cool ...
Thanks
Good Job po
Salamat Sir.
Hindi pwede ikabit ang switch float direk sa kuryente?
Pwedi naman po..sa maliliit na pump sir.
Pwde ba Yan sa line to neutral o may magbabago jan
Same lng po sir.
Sir good day .asked kolang po sir if okey lang gamitin ko yung connection nito sa 3phase my mababago poba ng connection?
Same connection..bale ang sa supply nyo lng po..f 220v kayo line to nuetral...yan po gamitin nyo sa control
Salamat po sir..🙏🙂
Welcome po
bago design n floater kasi ang ginagamit ung may bola sa loob?
Same connection lang yan Sir. Same function
Sir anong klaseng magnetic contactor ang ginagmit mo?... Basta khit ano lng ba ang ggamitin ntin?
May mga mqgagandang brand po gaya ng Schnieder or Fuji
Master,pwede po ba pump motor lang gamitin.lahit wala na pressure tank para sa roof deck level ng 2nd floor na may overhead tank
Pwedi naman walang pressure tank Sir. Storage tank lng sa baba..
Hello po, Pwede po na magset up ng pump na storage tank lng an gamit at walang pressure tank?
Pwedi naman po..
Boss ginaya ko ung wiring mo sa float switch na tatlo linya .black , blue , brown .. Bale kinuha ko lanh na line is black and blue . Pero hindi namamatay ung motor .. Pero sa tester pumapalo at namamatay namn .. Bagong palit lang ung magnetic
E up nd down nyo po manually..check f gumagana..check nyo rin contactor baka ng bond ang contacts po
Sir Tanong q lang poh yun poh bang Isang klase Ng float switch pwede din poh bang baligtarin Yung koneksyon nun kagaya Ng dinemo nyo salamat poh😊
Ito po yung ibang klase ng float switch new vid po ua-cam.com/video/YjSjsBOpWJs/v-deo.html
Goo evening sir .. sana po gumawa ka rin ng tutorial po para po duon sa normaly open po na float switch
Ito po video ua-cam.com/video/x8NTrX9cXvY/v-deo.html
Pero floatless gamit ko jan..isa lng kasi fl sw ko. D pa nakabili.hehe
@@LocalElectricianPH sir taga manila ka lang b
Cebu po Sir
Hala Ang layo Pala..akala ko manila ka Ang sir..
Magkano magpaturo Sayo sir... Maglagay Ng low pressure switch sa water refilling station
Hingi ako ng advice kung ilang hp ng water pump, ano type of pump ang kailangan para mag supply ng tubig sa overhead/storage tank sa 4th floor.
Lalagyan ng float switch
Nawasa/gripo/water distric ang supply ng tubig.
Kailangan lang pa akyatin sa taas.
Pwde bang di na gamitan ng pressure tank dahil push lang ng tubig pataas ang purpose. No need pressure..
No need pressure tank Sir. Kailangan nyo lang ay storage tank sa baba..para may pundo..kasi d 0wedi e recta sa gripo ang pump.mbaka mamaya walang supply ng tubig masira pump nyo..dapat meron kayo dalawa tank..baba at overhead dn dalawang float switch...sa motor pump naman...mas prefer ko don kayo sa supplier mag tanong Sir. Mas alam kasi nila yan f ilang hp bagay sa building nyo po.
Bago lang po sa channel niyo, tanung ko lang kung anung brand & model ng gamit niyong tester sa video?
Newstar UT202 po
@@LocalElectricianPH maraming salamat sir, sana patuloy lang kayo gumawa ng mga video sa mga electrical at mga related sa DIY, napaka dali maintindihan at very helpful ng mga video content niyo
Sir manila ba kayo? Baka pwede mag painstall 2 tank lalagyan ng switch
Cebu po Sir.
Boss khit wlang magnitic contactor pwd b mag lagay nang float switch sa c.b. lng pwd b yun at paanu e wiring
Pwedi naman po sa maliliit na pump. Make sure lang may circuit breaker na sakto sa FLC ng motor
panu paps kung yung pag low level ang tubig saka di aandar ang water pump para di masunog yung motor.
Ito po vid ua-cam.com/video/QH5OsegCp4Q/v-deo.html
sir,tanong ulit po,pag meron na po bang overload relay ang pump na nakakonekta sa contactor,di na po ba kailangan ang automatic pump control?
Yung ibang pump meron yan thermal fuse. Sa malakihang motor kasi need talaga ng control dahil sa inrush current
Idol,,next time medyo I highlights mo po Ang wiring diagram KC malayo camera,,Hindi malinaw sir
Noted po sir. Thank you.
Yung 95 at 96 po sa overload relay ay normally Close? Pano po kapag gumana na yung MC diba mag-oopen edi mapuputol yung supply. Tama ba
Nope. Ang auxilliary contacts ng mc sir ay iba sa overload relay..magbbago lang po ang contact ng o.l relay kung merong overload sa circuit.
@@LocalElectricianPH ahhhh gets. Akala ko lahat mag bbago. Hehe maliban pala sa overload relay. Nakalimutan ko yun hehehe. Salamat sa mabilis na pagsagot sir. Beginner here. God bless.
Wwlcome po
Sir ok lang po ba 13amp contactor din wlang overload relay..1hp LNG po yung motorpump
20A contactor po tapus 6 to 8A overload relay...useless ang contactor f walang overload relay Sir
Salamat boss.ok napo overload ko 8A...kaso yung contactor nabili ko13amp lang..depo pwde to 1hp? Maliit LNG to boss?
Pwedi naman po..kaso mabilis mg init contact nyan...onserve nyo png f hindi umiinit ang contactor
pls add in discription ang mga kakailanganinna materials ty po
Yung floater sw.as is napo yan Sir. Sa breaker..magnetic contactor at overload relay ay dependi po sa ilang hp ang pump nyo po.mg base ang Amperahe nya
idol pwdi bang isabay gamitin ung floating switch ung a1 at b1 kung dalawa motor ung isa para sa suplly sa tanki ung isa nmn sa pressure tank.
Pressure switch gagamitin natin f may pressure tank tayo sir. At pressure gauge para makita natin ang setting natin po.
Ask ko lng bkt di nag automatic shutdown Ang motor pump kht puno na tanke ng tubing pls reply now
Baka po sira na float switch nyo Sir.
Boss Tanong lng pwede ba Yan e direct sa motor mismo d na gagamit ng magnetic contactor??
Pwedi naman po sa maliliit na pump..gamit lng kau thermal cb or gfci outlet
@@LocalElectricianPH 1hp poh Yung motor na gagamitin boss ok lng poh ba??
Lagyan nyo po contactor Sir.
idol kailangan ba talaga ng contactor panglagay niyan
Yes po for protection sa pump nyo. Pero f D.Y.I ers po kayo Sir. Gagana naman po yan kahit floater switch lng at recta sa pump. Gamitan nyo lng ng thermal Circuit breaker or gfci outlet for additional safety
boss pa advice po ano magandang gawin. Kase yong water pump or washing machine namin pag umadar mag blink mga ilaw namin. ANo po magandang gawin... salamat.
E separate nyo po lines nyo sir
@@LocalElectricianPH separate na sya sir, water pump lang naka connect. Sa unang start lang ng water pump or washing machine sya mag blink mga segundo lang tapos normal na uli. Hindi ba kaya masulusyonan ito ng magnetic contractor?
Voltage drop po yan Sir. Malaki kc starting current ng motor loads. Try nyo rin po higpitan mga turnilyo ng panel at lights.o socket f bulb. Check nyo rin baka maliut wire size nyo. Topus marami kayung loads.
Boss...may video ka pano wiring nung contactor tsaka breaker?
Pwedi kayo mg message sa fb page Sir
@@LocalElectricianPH thank you po sir..nagmessage na po ako
Kaya ba neto yung 12v power sir?
Kaya po sir sa floatswitch
Idol pano kong parating puno like like 1month na pono yung tubig kombaga walang patayan nag contactor. tanong oki lang ba ang magnetic contactor 24/7 on? Hindi bayan ma overheat o amoy sunog?
Hindi naman po basta yong magandang brand po..ang motor nyo lng po kawawa panay andar..wala po ba back up duty pump?
@@LocalElectricianPH idol salamat nag reply ka. Palagi ako nanonood sa fb mo. Hahaha nagreteply ka din doon..
hindi idol yung motor ko ordinary lang 0.5 Hp basic dayuan motor with bladder tank. Na may pressure switch naman para matic off..
@@LocalElectricianPH inaalala ko lang. Bagong bili na cmagnetic contactor pag naka on parang medyong medyo parang amoy sunog.cguro baka kasi pag matagal halimbawa 24/7 straight mag overheat..
Pa double check po sir..baka may loose contacts
Ayos kayu sir Sana po ma post Ang diagram para sa tangki nmin ako nlng mg lalagay..
Meron po yang diagram.nasa video po
sir tanong lang pede po ba gamitin yan kapag dc ang supply? kase ung motor ko dc 180w
Pwedi naman po..gamit kayo ng DC coil na contactor
Bka nman idol...ung actual wiring ng circuit breaker... magnetic contactor n overload and also ung float switch...slmt
Yes po..yan napo yun sir. Saan banda po kayo nalito? Peedi rn po kau mgessage sa fb page natin..assist ko kau
@@LocalElectricianPHsir ano po fb page ninyo?
@lovelyabangan9728 electricians guide
Sir baguhan lng aq un po bng float valve ang maging water level nya
Iba poxang float valve sa float switch Sir. Mechanical On and Off po ang float valve
Lods 2 floats switch tutoril wiring sana mapansin
Ito po sir video ua-cam.com/video/x8NTrX9cXvY/v-deo.html
Bosing pasend naman yong description ng magnetic contactor or kung may link para makaorder ay mas ok. ty
220vac ang coil. Contacts ay 30A
Sir Gagana ba yung ganitong set up if gagamit ako ng 24VDC supply? DC din po yung motor
Gagana po. Parehas lng yan diagram
@@LocalElectricianPH thank you sir. last na tanong po. if gagamitin ko po itong diagram for drain, masisira po ba yung motorized valve na gagamitin ko?
Controls lng naman po yan Sir f tama ang power circuit at control circuit wala naman po maging problema sa electrical system
boss ganito prin b ung set up nito kung sakaling lalagyan ng start stop botton?
Ganyan pa rin ang wiring sa control madagdagan lng sa line 1 mo..yang start at stop buttons po
Ilan ba sir ang normal na gamiting Amperage sa magnetic contactor para sa 1hp na water pump.
Gamit po kau 20A contactor set with 5 to 8A overload relay
Sir ask lang po ako, kong ok lang na gamitin float kahit walang Pressure tank
Yes po..presure switch po pag presure tank sir
kuya dapat ba ganyan din na mc ang ikakabit? pano kung galing lng sa outlet yung source ng power pano ang koneksyon non?
Dependi sa power ng pump nyo sir. F sa outlet yung maliliit na pump. Gamitan nyo lng ng thermal circuit breaker sir. Tapus GFCI outlet
@@LocalElectricianPH .5 hp lng nmn yung pump ko kya sa outlet ko lng muna kinabit
Halimbawa paglow level na Ang tank gusto mo off Ang pump mo pati Ang high level Ng tank mo off rin Ang pump puede ba!
Need nyo po isa pang float sw para sa storage tank at isa rin sa overhead tank po.connected in series
Pwedi po ba na breaker lang ang gamitin?
Sa maliliit na pump pwedi nMan po. GFCI outlet or thermal cb
@@LocalElectricianPH sir pano po connection ng thermal cb at float switch sa 1hp motor pump?
Same function as ckt breaker with thermal overload protection po..same connection as ckt breaker
Boss yang kulay orange na dalawa is lahat ba yan may tubig sa loob? Yung sa amin kasi is hindi na sya nag aautomatic na mag on ang pump kapag wla na laman ang tangke need mo pa pukpukin ang tangke para umandar ung pump. Sana po masagot salamat
D naman po..tantyahan lng...e test nyo po muna simulate sir manual test
@@LocalElectricianPH salamat po sa pag sagod. Gaano pala kadaming tubig ang ilalagay doon sa orange na floater switch po?
@mackymcquestion9650 tantyahan lng sir.pwedi nyp e test muna up and down f mg trigger ang switching..trt half muna
@@LocalElectricianPH bale yung dalawa po ang lalagyan ng tubig?
@mackymcquestion9650 kahit po yong isa lng...basta gagana na ng maayos
Pweding walang presure tank bos
Yes po....ang pressure tank presure switch po gamit doon Sir.
Sir ask po. Pwde po bayan isabay ang water pom.para sabay off.
Ano po ibig nyo sabihin sir? Recta sa pump ang float swich? Walang contactor
Kelangan po b may magnetic contactor? Gusto ko sana kabitan ung tanke ng tubig namin. Submisible water pump kc nkakabit taz control may control box
Opo sir safety ng motor po yan
sir kailangan pa dn po ba ng overload relay kahit meron pong apc ang pump?
Yes po lalot malaki pump nyo Sir
Ano po ginamit nyu na circuit breaker dito ilang amperes?
20A po. Good for 1hp motor and below
Sir good day ano cause ng stuck up na float switch at cause na mag melt yung float switch kung matagal o mahaba yung time ng pag refill. Nangyari kasi naubos ang tubig sa tanke ko kasi nag stuck up yung float switch ko nung inalog ko gumana sya pero nang e chk ko ng umaga na nag melt o nusae yung float switch
Baka nka recta po kayo sa motor to float switch Sir...idaan nyo po ng magnetic contactor para hindi bogbog ang float switch Sir
Sir ano mas maganda 18 amp or 25 para sa 1.3 waterpumpmotor di kasi available ang 20 amp.. sana mapansin nyo po
Aling pong 1.3 Sir? 1.3 hp? O 1.3 kw?
1.3 hp po sir.
Sir! Ano po ang brand and model ng magnetic contactor with overload relay switch na gamit mo? Naghahanap kasi ako para sa 1hp na pump namin. Baka po may ma recommend ka. Thanks.
Ito po Sir plug and play Japan brand po yan. Para iwas sakit sa ulo shope.ee/3fVP0Peurw
Sir ilang ampers po ba ang kailangan sa cercuit breaker at sa magnetic conductor??? 1.3 ang motor namin... sana ma pansin nyo po..
1.3 kw? O 1.3 hp? Po ba
Gandang gabi sir pwede ang makabili ng isa wala kasing mabili dito sa amin
Meron po marami sa online Sir
Location nyo po
Sir gud morning salamat po s vision,sirpahingi po sir ng diagram,subukan ko po salamat,, thank you
Sir BI at B2 ba gagamitin if Yung motor NASA baba at Yung water tank,purpose ko KC mag off Ang motor if Wala na sayang mahigop na tubig SA tangke.Tama Po ba na b1 at B2 gamitin ko.
Yes po yong normally close para f low level mg open sya
Sir pwdy ba mae kabit ang wire ng floater direkta sa crct breaker.my solenoid kasi nkkabit..
pwedi naman po..
Hi Sir Question lang po, kinabitan po ako ng floater mga 1 week npo, nung ginamit npo nmin , nag tataka po ako bakit nung naka on npo siya ay aandar siya ng 9 to 10 mins pra mag puno ng tangke tpos mammatay na siya tpos mag o on siya ulit ng every 2 minutes mag k karga siya tpos m mmtay kda 2 minutes.. eventually mammtay din siya kso di siya continues ng isang bukas lang po.. tnk u
Good day po sir. Baka po hindi maayos pagka set ng floater po. Pwedi po yan ma adjust ang sensitivity nya. Lagyan o bawasan ng tubig ang loob ng floater po
@@LocalElectricianPH maraming salamat po sa reply.. tumatanggap din po kyo ng service dito sa pasay..tnk u po ulit
Cebu po ako sir. Pasensya po.
@@LocalElectricianPH sori po tnk u
Galing nyo boss! salamat napa clear ng explanation nyo 😊👍👍👍 Tanong ko lang po kung pwede ba yan i connect sa solenoid valve para ma auto shut off yung supply? thanks!
Pwedi po gawan nyo lng control sir.
@@LocalElectricianPH sana may video din po kayo. Salamat uli boss 👍
Wala po ako solenoid sir. Pero f supply lng po..pwedi naman float valve. Mamatay rn sya kapag puno na tanke nyo sa baba sir
@@LocalElectricianPH Hola saludos desde Argentina, el flotador del video, que tipo es? Que modelo es? Estos tipos de flotadores, ¿Es igual o similar a los flotadores que tienen una forma cuadrada?
@@LocalElectricianPH Hello, pagbati mula sa Argentina, ang floater sa video, anong uri ito? Anong modelo ito? Ang mga ganitong uri ng float, ito ba ay kapareho o katulad ng mga float na parisukat ang hugis?
para saan po ba ang float switch,sa presure o sa storage tank?
Fl sw..storage...pressure sw..sa press tank