Seismic Load for Warehouse design in Staad pro

Поділитися
Вставка
  • Опубліковано 7 лис 2024

КОМЕНТАРІ • 12

  • @mdafzalansari5232
    @mdafzalansari5232 3 роки тому +2

    Really impressed from your technique of teaching so simple nd clear...Salute you sir...

  • @dipendranathbhowmick6577
    @dipendranathbhowmick6577 Рік тому

    Can u please assign seismic parameters in dynamic method?

  • @a.v3467
    @a.v3467 4 роки тому +2

    Great sir. Thanks

  • @spcehod_civil754
    @spcehod_civil754 4 роки тому +1

    why we have consider EQ in X direction only ,for +ve and -ve? why not in Z direction?
    In general we workout for X and Z both directions

    • @SteelDesign1
      @SteelDesign1  4 роки тому +1

      In 2d analysis we can consider Eq +/-X only. if we do 3d analysis then only we can consider EQ in X & Z directions.

  • @aleximmanuel3621
    @aleximmanuel3621 3 роки тому +1

    An important point is the height of the structure is to be defined I n seismic definition .then only staad will calculate time period based in Is 1893 formula which 0.085 h^ 0.75 . If not defined then staad will calculate as per rayleigh method as mentioned in staad manual

  • @sureshkumar-ji5kn
    @sureshkumar-ji5kn 4 роки тому +1

    Pls explain
    Why we not assigned Selfweight in DL case??we assigned self weight only in seismic definition??

  • @saratchander1071
    @saratchander1071 4 роки тому +1

    Please share earlier parts also.
    Regards

  • @EducationByhamzahamid
    @EducationByhamzahamid 3 роки тому +1

    Sir definition mein bhi to wind load fir apne load case details mein wind load kyu liya

  • @jigneshlad9449
    @jigneshlad9449 2 роки тому +1

    Time period not given why?