  • Safety clearances in extra high voltage substation are very much important to maintain the basic insulation level of the system. If the system is designed without proper clearances there shall be insulation break down and flash over. A substation or a system faces several over voltage condition, due to lightning, due to switching or fault etc. These over voltages are capable enough to breakdown insulation and cause flash over.
    #SafetyClearance, #BasicInsulationLevel, #BIL, #ElectricalTechnologyAndIndustrialPractice
    What is safety clearance
    sectional clearance
    phase clearance
    phase to phase clearance
    earth clearance
    phase to earth clearance
    ground clearance
    basic insulation level
    basic impulse level
    lightning impulse voltage
    switching impulse voltage
    power frequency over voltage
    why clearances are required in substation
    clearances in substation
    what are the clearances to be maintained in extra high voltage substation
    bil
    Hope you have enjoyed this video. Please like, share, comment and subscribe to this channel
    THANKS FOR WATCHING......

КОМЕНТАРІ • 20

  • @e-powersolution7225
    @e-powersolution7225 Рік тому

    I think section clearance should measure from the live point to person operating , kindly check once. 5:43

  • @christopherbarber5228
    @christopherbarber5228 3 роки тому

    Thanks so much, very good recap.

  • @SufiShahHamidJalali
    @SufiShahHamidJalali 2 роки тому

    In your video at time 8.32 you have multiple values of lightning impulse withstand peak voltages like 450/550/650 kV for 132 kV system rated volage. Can you say why? Thanks.

  • @shivanikoleti9917
    @shivanikoleti9917 3 роки тому

    Wt is switching impulse voltage and lighting impulse voltage ...

  • @narenchauhan3241
    @narenchauhan3241 4 роки тому

    Thank You Sir..

  • @nitinsharma-rw3zz
    @nitinsharma-rw3zz 4 роки тому

    Hi good explanation. Please let me how we select gap in two equipment in same section.like gap between ct and cb

  • @Krishnasaini
    @Krishnasaini 4 роки тому

    hi, do you work in any safety testing laboratory?

  • @AmanKumar-jp1fd
    @AmanKumar-jp1fd 5 років тому

    Please elaborate about testing of power transformers,,,,

  • @travelingwithsun
    @travelingwithsun 4 роки тому

    Ground clearance is basically the distance between ground level and bottom of any insulator as per IEC 61936.

  • @thinkseeeatthroughvickus4555
    @thinkseeeatthroughvickus4555 4 роки тому

    can you advice where u took that clearance chart from?

  • @himanshu2232
    @himanshu2232 5 років тому

    Please make vedio on cb selection for substations.

  • @pramodgavit7666
    @pramodgavit7666 5 років тому

    Please guide for Lt and Ht also

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 років тому

      Ht and lt systems are mainly housed inside a panel. So the assembly could be type tested at lab. Hence there is no recommended clearance. Manufacturer designs as per their standard and make high voltage tests on that. If the system withstands the design is correct. Also these panel bus bars has sleeved insulation.

  • @enamulhaque630
    @enamulhaque630 5 років тому

    Please mention IEC reference no.