Motor Star mai chal Raha hai Delta mai nahi chal raha hai , मोटर स्टार में चल रहा है डेल्टा में नहीं

Поділитися
Вставка
  • Опубліковано 19 жов 2021
  • Motor Star mai chal Raha hai Delta mai nahi chal raha hai , मोटर स्टार में चल रहा है डेल्टा में नहीं चल रहा है
    #stardelta
    #inductionmotor
    #stardeltastarter
    #starconnectedmotor
    #deltaconnectedmotor
    - Solved queary in this video -
    1- why motor run in star not in Delta
    2- motor run in not run Delta
    3- Star connected motor
    4- Delta connected motor
    5- Star delta control wiring
    -About this video -
    Dosto aj ke es video mai Star delta motor star mai to chlta hai lakin delat mai nahi chl raha hai motor kis reson se star mai chlta hai lakin delat mai nahi chalta hai es video mai ham eske reson ka bare mai janege aur sahi connection ka bara mai beta kerege es video mai electrical interview se related questions bhe bataya gya hai video ko complete watch kerey

КОМЕНТАРІ • 36

  • @shravanyadav395
    @shravanyadav395 2 роки тому

    Very helpful video sir 👌👌

  • @rohansharma5794
    @rohansharma5794 2 роки тому +1

    NICE VIDEO BHAI

  • @SureshKumar-mg7xy
    @SureshKumar-mg7xy 5 місяців тому

    CLS panel.ki.video.dalo.bahi

  • @kuldeepkapoor7537
    @kuldeepkapoor7537 Рік тому

    Sir Delta main agar ek coil ko ek hi phase dey to kya hogga sir or baar baar on karey to kya hogga bataye massage par please

  • @totuga8555
    @totuga8555 Рік тому

    Trip kyon hota hai motor ek winding mein ek hi pace a raha hai two shot kaise hoga kya olr ke vajah se thik hoga theek hai bataiye thoda mujhe samajh mein nahin a raha hai

    • @Targettechnician
      @Targettechnician  Рік тому +1

      Agar delta mai ak coil ko 415 nahi melaga to trip ho jaya ga

  • @ArjunYadav-re1fo
    @ArjunYadav-re1fo 2 роки тому +1

    Sar yah problem bahut a rahi hai kripya help Karen

    • @Targettechnician
      @Targettechnician  2 роки тому

      Kya problem hai

    • @ArjunYadav-re1fo
      @ArjunYadav-re1fo 2 роки тому

      Motor star se delta hone ke bad delta jhula automatic gir jata hai uske bad auto switch se connection hone ke bad 1 minut mein chalu hota hai aur FIR 1 minut mein wapas gir jata hai

    • @paragpatil4663
      @paragpatil4663 2 роки тому

      @@ArjunYadav-re1fo connection proper check Karo motor to Startor end Tak....fir meggar s ek baar cable bhi check Karo.....Saare connection loose to nahi

  • @anupkurrey5485
    @anupkurrey5485 8 днів тому

    Star me agar nahi chal raha h to kya kare wo bolo

  • @anilnegi7941
    @anilnegi7941 Рік тому

    Bhai moter ka wiring nekal kay bhe dheeka tho bhe delta mai stater trip ho ja raha hai kyu

  • @alokkundu9263
    @alokkundu9263 2 роки тому

    Motor delta me hai mcb on krne se 5 sec chlta h fir bnd ho jata hai connection sab sahi hai

  • @kuldeepkapoor7537
    @kuldeepkapoor7537 Рік тому

    Sir star Delta ki motor hai resistance 1.9
    .5
    .7 aa raha hai winding ka sir motor kharab hai ya nahi bataye please

    • @Targettechnician
      @Targettechnician  Рік тому

      Motor ke winding resistance unbalanced ho gya hai and motor kitne ho ka hai

    • @kuldeepkapoor7537
      @kuldeepkapoor7537 Рік тому

      @@Targettechnician sir motor 15 HP sey jayda hai.
      Motor body sey short nahi hai par resistance unbalnce hai sir motor kharab ho Sakti hai kya bataye resistance ki valve pahley massage main batayi hai ,motor thik hai ya nahi ye bataye please

    • @Targettechnician
      @Targettechnician  Рік тому

      Winding resistance unbalanced ho gya h ak bar magger ker lo magger value 1 maga ohm ana chiya ager nagi aa raha to motor kherab hai

    • @kuldeepkapoor7537
      @kuldeepkapoor7537 Рік тому

      @@Targettechnician OK sir thanku very much reply key liye

    • @Targettechnician
      @Targettechnician  Рік тому

      Like and share

  • @totuga8555
    @totuga8555 Рік тому

    Coile Ko jab ek pace nahi milta hai tu kya overload relay trip hota hai kya phase failure ko relay science karke trip kara deta hai kya lekin relay mein to do hi production rahata hai short circuit overload aur bhi kuchh rahata hai kya matador thoda clear kijiye

    • @Targettechnician
      @Targettechnician  Рік тому +1

      Relay mai overload and phase failure ka protection hota hai short circuit ka protection nahi hota hai mpcb mai 3 protection hote hai phase failure overload and short circuit

    • @totuga8555
      @totuga8555 Рік тому

      Sar Thankyou Mera doubt clear Ho Gaya aur sar agar koi breaker mein overload ka protection hota hai to sar short circuit kabhi to protension ho gai kyunki overload mein jyada current Lene se trip ho jata hai short circuit mein bhi to jyada current jata hai to trip to vaise bi hoga

    • @Targettechnician
      @Targettechnician  Рік тому +1

      Ap kaha se ho

    • @totuga8555
      @totuga8555 Рік тому

      ​@@Targettechnician sar me West Bengal Kharagpur se hun Mera kuch kuch doubt rahata hai sar Mai electrician ka abhi kam seek raha hun mujhe aapka kabhi kabhi help chahie doubt clear karne ke liye kisi electrician ke andar new Sikka taiyar ho raha hai usi mein mein kam kar raha for electrician

    • @Targettechnician
      @Targettechnician  Рік тому +1

      Ok

  • @user-vp4sm2bv2q
    @user-vp4sm2bv2q 9 місяців тому

    Hello sri apko mobail number pilis