Keyhighlights 3:51 - configure profibus of S7-300 in simatic step7 project file 4:03 - S7-300 profibus S7 subnet ID must be the same on S7 subnet ID in the project file of S7-1200. baud rate must also the same 5:45 - install gsd file of CM on simatic step7 project file 6:22 - adding CM module to profibus, the address of CM must also the same on the simatic step7 project file and tia portal file 6:46 - adding I bytes and Q bytes for the S7-300 transfer area 10:43 - download configuration to S7-300 11:08 - online switchover for S7-300 13:06 - download configuration to S7-1200 14:47 - program S7-1200 then download [reference of IB1 and QB1 was in HWconfig 14:08] 16:07 - add DB with bytes then download to S7-300 24:15 - since IB10 and QB10 is use in S7-300 program then its configuration must be same 25:00 - after download program to S7-300 then monitor it 25:29 - testing via modify operand for QB1 of S7-1200 that will reflect to DB1.DBB2 "mbyte1" of S7-300
Hello sir Can give me hints for Two 313c-dp working on redundancy We want to take data of redundancy plc on s7 1200 with cm1243-5 as master through profibus Is it possible If yes Then CM 1243-5 is not available in samatic manager 5.7 why
A ơi cho e hỏi với. Ban đầu e làm giống anh thì truyền thông bình thương. Rồi 1 thời gian sau simatic của em bị lỗi e cài lại sau đó e thử dowloaf lại project thì trên plc báo lỗi ạ. Cho e hỏi có cách nào sửa ko ạ. Hay khi em gỡ sinatic em xoá luôn 1 cái software hỗ trợ truyền thông giữa 2 phần mềm ko a
After I tried many ways and found that if choose total length in Tia portal then must use SFC14 and SFC15 in step 7 if not cannot read and write data from s7 300. If you choose unit in tia portal then no need to use SFC14 and SFC15.
@@khaihoanle5314 If using the method of downloading the gsd file of the s7-300 to install the s7-1200 Tia pprtal (S7-300 = master ,S7-1200=slave) this method can be done or not.☺️
@@khaihoanle5314 Let me ask you a question. If you try to do it, then GSD file 1242-5 dinostuc says that Different communication dada is caused by what and how to fix it?
Keyhighlights
3:51 - configure profibus of S7-300 in simatic step7 project file
4:03 - S7-300 profibus S7 subnet ID must be the same on S7 subnet ID in the project file of S7-1200. baud rate must also the same
5:45 - install gsd file of CM on simatic step7 project file
6:22 - adding CM module to profibus, the address of CM must also the same on the simatic step7 project file and tia portal file
6:46 - adding I bytes and Q bytes for the S7-300 transfer area
10:43 - download configuration to S7-300
11:08 - online switchover for S7-300
13:06 - download configuration to S7-1200
14:47 - program S7-1200 then download [reference of IB1 and QB1 was in HWconfig 14:08]
16:07 - add DB with bytes then download to S7-300
24:15 - since IB10 and QB10 is use in S7-300 program then its configuration must be same
25:00 - after download program to S7-300 then monitor it
25:29 - testing via modify operand for QB1 of S7-1200 that will reflect to DB1.DBB2 "mbyte1" of S7-300
❤️
Hello sir
Can give me hints for
Two 313c-dp working on redundancy
We want to take data of redundancy plc on s7 1200 with cm1243-5 as master through profibus
Is it possible
If yes
Then CM 1243-5 is not available in samatic manager 5.7 why
❤
A ơi cho e hỏi với. Ban đầu e làm giống anh thì truyền thông bình thương. Rồi 1 thời gian sau simatic của em bị lỗi e cài lại sau đó e thử dowloaf lại project thì trên plc báo lỗi ạ. Cho e hỏi có cách nào sửa ko ạ. Hay khi em gỡ sinatic em xoá luôn 1 cái software hỗ trợ truyền thông giữa 2 phần mềm ko a
Hi, when i try this method i got an error on both s7300 and s71200. Could you plz suggest me.
After I tried many ways and found that if choose total length in Tia portal then must use SFC14 and SFC15 in step 7 if not cannot read and write data from s7 300.
If you choose unit in tia portal then no need to use SFC14 and SFC15.
Contact me to whatsapp bro
ad cho e xin cái file CM1242-5 ko e cảm ơn
Nhắn vào mail cho mình địa chỉ với nhé: khaihoanhaui@gmail.com
@@khaihoanle5314 CHO E HỎI CÁI PROFIBUS NÀY MÔ PHẨM BẰNG PLCSIM HAY PLC ADVANCED KO VẬY
@@ntt3640 Mình thử trên thiết bị thật. Nên mình không biết PLCSIM ADDVANCE có mô phỏng được không!
Able to bring GSD file of Profibus S7-300 that is Master to install at S7-1200 that is Slave. Can this method be done?
Yes, If S7-300 is slave, S7-1200 is master
@@khaihoanle5314 If using the method of downloading the gsd file of the s7-300 to install the s7-1200 Tia pprtal (S7-300 = master ,S7-1200=slave) this method can be done or not.☺️
@@khaihoanle5314 Feel free to ask for some advice. thank you very much
@@Account_YT-hh4rz No bro, You must have a CPU S7-300 in Tia Portal
@@khaihoanle5314 Let me ask you a question. If you try to do it, then GSD file 1242-5 dinostuc says that Different communication dada is caused by what and how to fix it?
Newbie
Thanks sis