Inside the La Marzocco Linea Classic

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • Dave covers components and helpful tips to understand, operate and maintain the La Marzocco Linea Classic commercial espresso machine.
    _______________________________________________
    NEED HELP?
    Call, email, or message us! - www.espressose...
    _________________________________________________
    WHERE YOU CAN FIND US:
    Website - www.espressose...
    Facebook - / espressoservicenetwork...
    Twitter - / esnproviders
    Instagram - / espressoserviceproviders
    _________________________________________________
    WANT TO LEARN MORE?
    Check out our blogs - www.espressose...
    _________________________________________________
    CREDITS:
    "Home Base Groove" Kevin MacLeod (incompetech.com)
    Licensed under Creative Commons: By Attribution 4.0 License
    creativecommons...
    / grinchfist
    Music: www.purple-pla...

КОМЕНТАРІ • 44

  • @codeykamal5337
    @codeykamal5337 Рік тому +3

    This machine is pretty decent. I actually rebuilt one at work today. Makes great lattes. Your videos are super helpful!

  • @JimTMcDaniels1
    @JimTMcDaniels1 5 місяців тому

    WoW better insulate those 2 broiler tanks with some fiberglass insulation wrap like they do with their newer made exact ones!
    Otherwise it's costing electricity and making staff hot and wearing out the heating elements and related.
    Also since many find reduced maintenance by keeping the machines turned on 24/7 in a high use establishment.
    Great video, thanks for caring and sharing! I'm making labels for all the components to help anyone looking inside!
    Take care

  • @Alo1zz
    @Alo1zz Місяць тому

    Hello, I am a refrigeration technician in Alabama. I’m curious what the certification is for espresso machines. When I call schaerer they say I need to be certified to even get tech support. Do you happen to know where I can get certified?

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Місяць тому

      Good morning! There are no certification requirements to be a commercial espresso service technician except for the normal state and regional licensing. Each individual manufacturers requires you to be certified with their equipment in order to purchase OEM parts , receive trouble shooting assistance and offer new equipment to your customers. Some ask that you pay for the training and you will most likely need to travel to their location. Please feel free to reach out to our office if we can answer any additional questions. We are here assist you in any way we can. Ruth

  • @mosnet28
    @mosnet28 6 місяців тому

    why would the brew valve open during a reheat? Valve seat wear?

  • @TyeAnnaMaier-Boyce
    @TyeAnnaMaier-Boyce Місяць тому

    I started having a sticky button for my hot water, any thoughts how to fix that before i call the espresso tech just for that! Thanks

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Місяць тому

      It depends on the button. If it is a pad or a high voltage button, then you need a tech. Other than that, try cleaning it with a cloth.

  • @JimTMcDaniels1
    @JimTMcDaniels1 5 місяців тому

    Great Help, Thank you.
    But some of your advice for old machines:
    1. It does seem your advice to replace the Older Steam Broiler pressure(temp) controller when it goes out, with the $600+ PID controller kit is poor advice.
    Simply because it appears the company which makes the old style Sirai Pressurestat switch (P302?), still makes them for $100 new. Plus the pressurestat contains the electric contacts which turn on and off the heating element. So when you replace it, you are getting all new, unlike the PID which uses 2 expensive components which both wear out, to do the same thing. Plus even though the Brewing thermostat # L260 might no longer be available, its micro switch # 11981.10 (Cutler-Hammer# E47CMS01 20amp!) which is what wears out, is for cheap.
    2. Replacing the entire older 2 part brewer tank w/bolt on brewer heads for a newer tank with welded on heads... that's $$$$.$$ of dollars... I would think if a weak threads break/over tightened, new threads can easily enough be welded onto the old tank. I see a new gasket can be had for $7 plus shipping from a few sites.
    Take care.

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  4 місяці тому

      As a professional technician equipment owners are typically seeking improved performance. In the case of with upgrading to a PID, improved performance and less maintenance.
      Welding is not that simple or easy. Again, most equipment owners are seeking resolutions that are quick and efficient. IOf course, you can try all the things suggested but the potential for a poor outcome is not a gamble most business owners want to take.

    • @JimTMcDaniels1
      @JimTMcDaniels1 4 місяці тому +1

      @@EspressoServiceNetwork thank you for the reply. I'm not sure the PID is necessarily more reliable. Both systems rely on contacts which suffer high voltage arcing damage over time, each time the heating elements turn on and off, breaking the electrical flow. Yet the contacts in the mechanical are much cheaper to replace the unit.
      As far as the temp swings of the mechanical, when they were the latest, they were touted to be more reliable than the 10 deg you say you have witnessed and our customers and staff are happy with the accuracy of the mechanical. Some of us restaurants have tight budgets and have to do some repairs ourselves. Not to fear, there are more than plenty of work needed from the professionals, especially honest and caring ones like yourself.
      Take care

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  4 місяці тому +1

      Thank you for the kind words! The PID system uses a solid state relay. They can break but there are no contacts or wear n tear parts. If cost is an issue and temp fluctuation is not a concern then stick with the switch. Be careful not to lose the spring (its easy to do) or the c-clips and know that overtime the thermostat gets more and more out of range.

  • @violector
    @violector Рік тому

    Is there a way to have preinfusion on this machine?

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      The machine in the video is a semi-automatic so pre-nfusion is manual. The, AV, volumetric dosing model has a one second on/one second off that can be enabled or disabled.

  • @dominikzgodka1299
    @dominikzgodka1299 Рік тому

    Hi there, very helpful videos! Thanx! I Haven wieściom about my 10yo Linea Classic 3AV with No PID. How do I control brew temp?

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому +1

      There is a set screw that adjusts the pivot point of the switch height from the plunger on thermostat well. Turn off the machine when you adjust. 1/16 to 1/8 of a turn.

    • @dominikzgodka1299
      @dominikzgodka1299 Рік тому

      @@EspressoServiceNetwork thank you, found it:) and sadly I might have an issue with thermostat. I have a feeling that water coming out of brew groups is almost boiling. I wonder if this is the thermostat which failed does it make sense to fix it or should I just go straight for PID kit…

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      Move to a PID, definitely.

  • @integmy
    @integmy 2 роки тому

    Hi Sir, if brew pressure drop to 3bar on idle is that mean expansion valve is faulty? Tq in advance

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  2 роки тому

      You will only see the pressure gauge rise when the machine is reheating. If it is not reheating the pressure can drop all the way down to what your building pressure is. if there is a problem with the check valve it will not show the rise of pressure (expansion) and thus it's very hard to set your expansion valve at pressure
      If you just did a brew, it might not be reheating which means nothing is expanding.
      If you have a mechanical thermostat, it often takes up to 10 brews before it will start reheating?
      I hope that helps. If I can clarify something let me know.

  • @sanandre3091
    @sanandre3091 Рік тому

    Thanks for the Video..
    At 8: 22 CAN you please explain more about safety switch ? Which is then connected to heating element..
    In my Gb5 machine I found that sometimes the heating element stopped working and there is no steam pressure..

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому +1

      If the safety switch is connected to the heating element via the power wires, which is the case in newer machines, anytime there is not a good terminal connection the safety switch will build up heat inside itself and trip. Let me know if this helps.

    • @sanandre3091
      @sanandre3091 Рік тому

      @@EspressoServiceNetwork
      That means it's not a issue if he switch get tripped. We don't need to check machine for any abnormalities..right?
      We can reset the switch and start using the machine .. Am I correct?

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      It is an issue if your switch trips. This can lead to additional problems. You need to verify that there is a good connection. If there is not a good connection change the terminals and wires if needed. If your connection is good you may have a boiler fill issue or an overheating issue.

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      Yes, you can reset the switch and begin using the machine but you still need to search for the cause. Safety devices trip for a reason. Don't ignore it.

    • @sanandre3091
      @sanandre3091 Рік тому

      @@EspressoServiceNetwork Thank you!! Appreciate your help

  • @adamn480
    @adamn480 Рік тому

    ever have pump issues? for example a bad pump start capacitor ? Our Linea trips breaker during a rush

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      The breaker could be caused by a few things. Are you using a GFCI circuit breaker?.Pump capacitors will weaken or go bad over time but they do not typically trip a breaker. They will however blow a fuse on your main board if you are operating a volumetric dosing Linea.

    • @adamn480
      @adamn480 Рік тому

      @@EspressoServiceNetwork yes it’s on a GFCI. It did go off couple months back when we steamed too much and some of the internals wires looked wet but this time it keeps tripping the breaker, but nothing is wet.

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      @@adamn480 The GFCI may be bad.

  • @mhf5044
    @mhf5044 Рік тому

    During normal use how audible should the boiler contactor clicking on and off be? Ours is definitely present in the room, like placing a hard object on marble. Wondering if that’s normal or if I should have a spare on the shelf if it fails. 12 yo machine

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому +1

      The contractors are loud when they close. If the contractors have not been changed, it might be time to change them. Depending on use, change them every other year or max life 4 years.Hope that helps.

    • @mhf5044
      @mhf5044 Рік тому

      @@EspressoServiceNetwork that does help, thank you for the reply!

    • @Maru-on4mu
      @Maru-on4mu Рік тому

      Yup that’s normal

  • @lukeschneider9949
    @lukeschneider9949 Рік тому

    can I change the temperature of the brew boiler separately from the steam boiler? I'm working with a linea classic av2

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      Yes, they are independent

    • @lukeschneider9949
      @lukeschneider9949 Рік тому

      @@EspressoServiceNetwork I guess I should have asked, how do I change the temperature of the steam boiler? also, will lowering the temperature of the steam boiler cause the steam pressure to be less? right now my machine's steam wand is putting out so much pressure that it's unmanageable

    • @EspressoServiceNetwork
      @EspressoServiceNetwork  Рік тому

      @@lukeschneider9949 Here you go ua-cam.com/video/odDmsjkjf6o/v-deo.html

    • @danielherrera7374
      @danielherrera7374 18 днів тому

      .

  • @raviyadav8743
    @raviyadav8743 Рік тому

    In my Linea Classic machine Brew pressure not going above 6bar even i increased Pump pressure by turning clock wise
    Please Suggest 🙏🙏

  • @Popcornbeetle
    @Popcornbeetle Рік тому +2

    Can’t stand techs that don’t care for scratching and banging equipment.