    In Forward cleaning method, where cleaning solution or flush water is flowed in the same direction of the normal feed flow
    Forward ( Normal ) cleaning must break up these foulants and push the foulant through all of the other membranes in the pressure vessel to exit out the brine side
    Advantage of reverse cleaning is that certain types of foulants concentrate on the feed end of the lead Membrane
    Biological foulants,
    particulates,
    colloidal matter
    are examples of foulants that usually are present on the lead end of the feed membrane.
    Difference between reverse cleaning and reverse flushing
    Implement reverse flushing to help control the very high differential pressure
    Reverse cleaning (using CIP chemicals) was the most effective at removing the biological foulants.