Ye bht achi advise th Pehle pumping check krna zaruri hai nhi to lgta hai system chock hai or phir flushing krne ke Baad vhi compressed dobara install kr dete hai pura mehnat weste ho jata hai
Sir ek sawal h month ago ek 2 ton k R410 ac mein gas charge ki to gas boht slow charge ho rhe the phir idu and odu ki flushing ki pipe ki bhe flushing ki filter bhe change Kya lakin wohe fault aata raha ap ka experience Kya kehta h is mein
Assalamu alaikkum janab jabir saab. Aapki video No. 1 Hai kaam sikneyvalokeyliye. Bas Pera ek doubt Hai. Compressor systeme rahneyka timepe 300 psi aur systemse alek hote time 500psitak the a haikya. Please
Mahamdul hasan, thankyou. Mjhay b idea hwa ha video bnanay k bad k is m bht s batan explain krnay wali rhty han. Theek h m jldi detail s video bnaon ga.
Assalamualaikum kya compressor ko bagair with out refrigerant unit me fill kie bagair us compressor ko hum load par sahi work kr raha hi ya nhi kaise pata kren plz reply
سر جی بہت اچھی ویڈیو بنائی ہے۔ سر جی 1/5 کا کمپریسر اگر 350 تک پریشر دے 500 تک نہ جائے۔ تو کیا اسکا پمپ بہت کمزور ہے؟ ہمیں کسی نے بتایا کہ اگر 500 سے کم پریشر بنائے تو وہ کمپریسر استعمال نہ کریں۔ پلیز جواب ضرور دی ۔
@@Jabirwaqas sir mere OGENERAL ac me indoor k first pipe pe ice aa rahi he.cooling bilkul nahi kar raha.or gas pura nikla he ac se.or ac ke pumping check karte time ac bandh karte hi suction line se dhua nikal raha he.to kya compressor fail he ?
Assalam walaikum Mera name muntejir he or Mera sawal he kis Cheege se flush Karna Sahi rahega petrol, yah thinar, yah R401B Please Reply jarur dijye GA or thoda tarika bataiye GA... Hum Bohat presan he
Allah ap k ilam r rozi m barkat dy ameen
Masha Allah very helpful Allah aap ke knowledge me or izafa karye
Vrey good
ماشاءالله سر جی بہت خوب جزاک اللّہ خیر
Ye bht achi advise th Pehle pumping check krna zaruri hai nhi to lgta hai system chock hai or phir flushing krne ke Baad vhi compressed dobara install kr dete hai pura mehnat weste ho jata hai
Thx sir ka samjane ka trika muze bohat psand aya aap ne bohat hi simple shabdo Mai samjaya hai very nice,and Thx.
Bht shukrya
Ustad ho to aap jaisa sirji
Phir koi pareshani nahi hogi
Very Informative Video for all AC Technicians
Bahut badiya tarike se apne samjhaya apne allah apko salamat rakhe
Excellent. We faced today same situation in two ACs
❤masha allah ustad apne bhot hi tasally se ssmja ya جزاک اللّه
MashaAllah Allah aap ki Umar my Barkat Daly
Thanks 22 👍❤️ good information. Janab
Very good information ji 🙏❤️👍
Vari nice jabir bai
Good information bahi jaan 👍
Very good informative video
Bhai bahot shukriya bahot acha video hai
Sir
Apne bahut ache se samjha Rahe hai
Good information sir ji
Good information sir.
Aap ne bahut ache se bataea
Very helpful video, thanks 🙏👍
Bahut achha se bataye apne
very nice information sir
Good information thankque sir
Excellent explained
Bahut achcha btayen sir
Ustad Allah apko iska ajare Azeem de Ameen
Nice video sir..
Good video
Good explanation
Thanks
Good explaination by u sir.
Lov from india for u.
Thankyou. Rajneesh.. ❣️❣️
Right 👍 from Sharjah city UAE Dubai 🇦🇪 but I belong to Amritsar Punjab India 🇹🇯👍🙏
Love and lots of respect for Amritsar. ❣️❣️❣️❣️❣️Punjabi ❣️❣️❣️❣️❣️
mashallah nice information
Thanks sir Very shelfful video
informative
sir jis compressor ki pumping thik hai. uski video jaroor banaye. sabhi technician confuse hain.
Ek no
Nice g
Good
Nice video sir
Great sir
Nice video sir👌
Sir ek sawal h month ago ek 2 ton k R410 ac mein gas charge ki to gas boht slow charge ho rhe the phir idu and odu ki flushing ki pipe ki bhe flushing ki filter bhe change Kya lakin wohe fault aata raha ap ka experience Kya kehta h is mein
Us ki pumping pressure check kry ..wo Kam Hogi jes ki wja say esa ho rha ha ..ku campresur pump Kam kar rha asi wja say charging late kar rha hoga ...
Well Explained.
Very niece chacha ji
Nicely Explained thanks
Good check
assalamu alaikkum sir aapki ye tho videome pahila videopar aap 500psi tak pressure therahehai.lekin outdoorme lagahuwa compressorme 300psi pressure daal raheho.aisa kiw.correct pressure kitnatak daalna chahiye.please
Good 👍
Shokriya Zabir Sar👍👍👍🇧🇩
Very nice bro
Assalamo alaycom o rah matholla,sir appko hajar salam,sir may appkale dowa kortha hoo Allah appko nek hayat Dan kore.
Waalaekumassalam.
Good information sir👍👍
Sir
Discharge pressure sab split machine main nahi check kar sakte hai.
Subscribed bicoused of the translate youv put on your job(put translate on every video)
Aleksandar , i will try my best to put subtitles in english under my every video,, thankyou for your concern..
Good sir
Duct split control nikkata hai outdoor ke 12volt jo contecter mai lagti hai
Aapka pahle wala channel dikha bahut acchi video hai
Thank you saab
Masha Allha 👏👏❤️
Try after oil change again, mostly pumping problems are will solve
lal
Assalamu alaikkum janab jabir saab. Aapki video No. 1 Hai kaam sikneyvalokeyliye. Bas Pera ek doubt Hai. Compressor systeme rahneyka timepe 300 psi aur systemse alek hote time 500psitak the a haikya. Please
Good sir ❤
Thanks sir
Brother Back pressure tuh outdoor unite kih slow slow kum raha hae compressor tuh good hae
Ap achii seh or ek video upload kare brother ♥
Mahamdul hasan, thankyou. Mjhay b idea hwa ha video bnanay k bad k is m bht s batan explain krnay wali rhty han. Theek h m jldi detail s video bnaon ga.
Agr slow slow necha ay pressure to compressor theek ha. Agr back pressure day, tb b compressor use kya ja skta ha lakin pump bht kmzor ho ga.
Please discuss ICM-220 lock out relay Waring cannection wih diagram.
Good ❤
Bahut shukriya apka
Thank you sir
Agr dhowan na nikly toh kiya camprasar theek ho ga jase ap ny perasar 300 kiya unt k andr
Zafar .pressure agr stable rhay compressor k andr to h compressor theek ha ,
JAZAKALLAH ❤
Many many thanks,
I can like your vedio once I want to like 100 times if any way you know pls inform me
Assalamu walekum
Thanks sir
Welcome sir
Sir scroll compressor ki pumping ki video b bena de
Thank you bhai Saab...
Thanks
Mashallah
Aslamualikum Sir Muja Apsa ek Sawal Pucna ha Vacuum karna ka Liya Ac on karna Chiya ya Of hor inka 2 no Wal on kra ya of peles Sir Replye me Think You
As salamualikum sir bohat sukriya app ka hamari malomaat me ezafa Kar ne ka
Sadik
It is kitchen curry recipe
Thanks for videos
Very easily explained sir
Thanks lot
hvac line is good career or age jakr ise business bhi kr skte h?
Sir best video for non inverter ac compressor test inverter compressor ko kaise check kre pumping ko
Rotary ka head chrck kr sakta hai kiya isi tarike se
thanks bro
Is Mai capplirry bhi Blok ho sakti hai 300 tk pressure kesy. Jay ga agr Blok hoi to ye wrong way hai agr inverter Ac ho to wo blost ho sakta hai
Gas rhte waqt kaise check kren k pumping less hai ya thik hai compressor...plz batadijiye...
Rizwan... pumping check krnay k lya lazmy refrigerant nkalni ho ge.
@@Jabirwaqas sukriya...
Jazaakallahu khaaira
Sir ya compressor rotary ha is MA ya piston
moin , kon sa piston
Thank sir
Assalamualaikum kya compressor ko bagair with out refrigerant unit me fill kie bagair us compressor ko hum load par sahi work kr raha hi ya nhi kaise pata kren plz reply
Fan motor ka connection nikal kr check kre ge only pumping ki saath me .....
Tq sir for this tip
Nice❤❤❤❤❤❤❤
سر جی بہت اچھی ویڈیو بنائی ہے۔ سر جی 1/5 کا کمپریسر اگر 350 تک پریشر دے 500 تک نہ جائے۔ تو کیا اسکا پمپ بہت کمزور ہے؟ ہمیں کسی نے بتایا کہ اگر 500 سے کم پریشر بنائے تو وہ کمپریسر استعمال نہ کریں۔ پلیز جواب ضرور دی ۔
Sir pumping less ac compressor men kya kya fault aate h
Nafees, cooling nhe ho ge ya bht km ho ge, ice a jay ge...
Ice kahan par aayegi .
@@Jabirwaqas sir mere OGENERAL ac me indoor k first pipe pe ice aa rahi he.cooling bilkul nahi kar raha.or gas pura nikla he ac se.or ac ke pumping check karte time ac bandh karte hi suction line se dhua nikal raha he.to kya compressor fail he ?
Thanks 😊 bhai
Sir 5 tan tak kitna pressure me chek kare
Assalam walaikum Mera name muntejir he or Mera sawal he kis Cheege se flush Karna Sahi rahega petrol, yah thinar, yah R401B Please Reply jarur dijye GA or thoda tarika bataiye GA... Hum Bohat presan he