Membrane Bio Reactor Process (MBR Technology)

Поділитися
Вставка
  • Опубліковано 24 лис 2024
  • MBR Technology - Membrane Bio reactor Process
    Membrane Bioreactors combine conventional biological treatment (e.g. activated sludge) processes with membrane filtration to provide an advanced level of organic and suspended solids removal. When designed accordingly, these systems can also provide an advanced level of nutrient removal. In an MBR system, the membranes are submerged in an aerated biological reactor. The membranes have porosities ranging from 0.035 microns to 0.4 microns (depending on the manufacturer), which is considered between micro and ultrafiltration.
    This level of filtration allows for high quality effluent to be drawn through the membranes and eliminates the sedimentation and filtration processes typically used for wastewater treatment. Because the need for sedimentation is eliminated, the biological process can operate at a much higher mixed liquor concentration. This dramatically reduces the process tankage required and allows many existing plants to be upgraded without adding new tanks. To provide optimal aeration and scour around the membranes, the mixed liquor is typically kept in the 1.0-1.2% solids range, which is 4 times that of a conventional plant.
    During MBR wastewater treatment, solid-liquid separation is achieved by Microfiltration (MF) or Ultrafiltration (UF) membranes. A membrane is simply a two-dimensional material used to separate components of fluids usually on the basis of their relative size or electrical charge. The capability of a membrane to allow transport of only specific compounds is called semi-permeability (sometimes also permselective). This is a physical process, where separated components remain chemically unchanged. Components that pass through membrane pores are called permeate, while rejected ones form concentrate or retentate.
    There are five types of membrane configuration which are currently in operation:
    1. Hollow fibre (HF)
    2. Spiral-wound
    3. Plate-and-frame (i.e. flat sheet (FS))
    4. Pleated filter cartridge
    5. Tubular
    Pre-treatment
    To avoid unwanted solids in the waste stream, which enters the membrane tank, fine screening is an essential pre-treatment step. This minimises an accumulation of solids and protects the membrane from damaging debris and particles, extends the membrane life, reduces operating costs and guarantees a higher sludge quality as well as a trouble free operation.
    Cost Considerations
    Although MBR capital and operational costs (membranes, oxygen utilisation, expert design, etc.) exceed the costs of conventional process, it seems that the upgrade of conventional process occurs even in cases when conventional treatment works well. This can be related to increase of water prices and the need for water reuse as well as with more stringent regulations on the effluent quality.
    Operation and Maintenance
    Most MBRs employ chemical maintenance cleaning on a weekly basis, which lasts 30-60 min, and recovery cleaning when filtration is no longer durable, which occurs once or twice a year. A deposit that cannot be removed by available methods of cleaning is called “irrecoverable fouling”. This fouling builds up over the years of operation and eventually determines the membrane life-time. All O&M tasks have to be done by skilled workers.
    Advantages
    • Secondary clarifiers and tertiary filtration processes are eliminated, thereby reducing plant footprint. In certain instances, footprint can be further reduced because other process units such as digesters or UV disinfection can also be eliminated/ minimised (dependent upon governing regulations)
    • Can be designed to prolong sludge age, hence lower sludge production
    • High effluent quality
    • High loading rate capability
    We M/S. AQUACARE SOLUTIONS ENVIRO ENGINEERS is a Pune based environmental and safety consultancy company working since 2004.We have well equipped and trained manpower having both professional and technical background. Our company falls under “Service Industry “ which provides Environmental and Safety services to the industry to meet their obligations under Environment act 1986 and factories Act 1948.
    We take pride saying our first member of our clientele is L’Oreal who maintains International Environmental and safety standards and we proudly say that we are keeping up to their standards.
    Our Products and Services are as follows :
    • Water Treatment Plants.
    • Waste Water Treatment Plant.
    • Effluent Treatment Plant.
    • Sewage Treatment Plant.
    • Water Recycling Plant.
    • Design Engineering And Process Consultancy Services.
    • Zero Liquid Discharge.
    • Process Water Recycle.
    • Water Recycle for Residential Complex.
    • Engineering Consultancy Services.
    • Operation and Maintenance.
    • Annual Maintenance Contracts.
    • Analytical Laboratory Services.
    It would be great pleasure to get associated into receiving valuable enquiries from your end & assuring our best service at your doorstep.

КОМЕНТАРІ • 18

  • @jijingihemenemmanuel4464
    @jijingihemenemmanuel4464 Рік тому

    nice video and after the screening, how can the oil and green be removed before entering the collection tank?

  • @sushantmisal2655
    @sushantmisal2655 2 роки тому

    लै भारी boss
    Very nice video

  • @jijingihemenemmanuel4464
    @jijingihemenemmanuel4464 Рік тому

    is there any monitoring device for some of the parameters such as Temperature, DO, pH that cant be connected to the computer?

  • @mahendrayeola8804
    @mahendrayeola8804 2 роки тому

    Good presentation and glad to see you.

  • @sushantmisal2655
    @sushantmisal2655 2 роки тому

    Very nice growth.

  • @ekanandkonjiwale7140
    @ekanandkonjiwale7140 6 років тому +1

    best technology...MBR

  • @chiragbhawaniwala
    @chiragbhawaniwala Рік тому

    Can I put an anoxic zone before mbr tank and after aeration?

  • @ABC-fm1wr
    @ABC-fm1wr 4 роки тому

    Which software do you use to create videos?

    Thanks so much!

  • @kaku782
    @kaku782 2 роки тому

    How Ican contact you??

  • @sayedshajahan7115
    @sayedshajahan7115 3 роки тому

    Full installation please send a video

  • @usguptaji7695
    @usguptaji7695 3 роки тому

    Sir classes lene ka ky processes hai

  • @tyzxcj34
    @tyzxcj34 4 роки тому

    No anoxic tank?

  • @geofryabroguena2249
    @geofryabroguena2249 4 роки тому

    Is this also need activated bacteria during process?

    • @aquacaresolutionsenviroeng8896
      @aquacaresolutionsenviroeng8896  3 роки тому

      Yes, Its based on Activated sludge process. We can maintain 8000 to 10000 MLSS in aeration tank so its required less footprint.
      For more details please reach us by mail to datta.yerudkar@aquacaresee.com

  • @sushantmisal2655
    @sushantmisal2655 2 роки тому

    👌👌👌

  • @slupek0
    @slupek0 5 років тому +3

    sweet alien accent brother

  • @rumiazhari7387
    @rumiazhari7387 3 роки тому

    Nice Islandic accent. So exoctic.

  • @sayedshajahan7115
    @sayedshajahan7115 3 роки тому

    Mbr