MDD & OMC OF SOIL I MAXIMUM DRY DENSITY & OPTIMUM MOISTURE CONTENT OF SOIL I MODIFIED PROCTOR TEST

Поділитися
Вставка
  • Опубліковано 25 бер 2021
  • #MaximumDryDensityTestOfSoil
    #OptimumMositureContentOfSoil
    #MDD
    #OMC
    #MDD&OMC
    #IS2720Part8
    #CivilEngineeringTutorials
    #YogeshKaushikSir
    #UPSCESE #SSCJE #STATEPSCAE/JE #GATE #QualityControlEngineer
    In this video, detailed discussion of #MDD (Maximum Dry Density) and #OMC (Optimum Moisture Content) test of #Soil as per #IS 2720 Part 8 has been done with its significance, which will be useful for aspirants of UPSC ESE/GATE/PSU's/SSC-JE /State PSC JE/AE exams and Quality Control Engineer on Site.
    Following content has been discussed in this video:-
    #MDD (Maximum Dry Density) and #OMC (Optimum Moisture Content) test of #Soil as per #IS 2720 Part 8.
    Video Link of #Gradation Test of #Soil:-
    • GRADATION TEST OF SOIL...
    Subscribe my you tube channel for further updates:-
    / @civilengg.byyogeshkau...
    PDF Link of MDD & OMC test of Soil using Modified Proctor test:-
    drive.google.com/file/d/1qrmA...

КОМЕНТАРІ • 59

  • @babafilmsharyana
    @babafilmsharyana 2 роки тому +4

    Very nice Sir G, your videos are very helpful for me. Thanks & be carry more videos....

  • @ehakim11
    @ehakim11 2 місяці тому +1

    Great! very interesting and step by step

  • @rickykumarsingh1600
    @rickykumarsingh1600 3 місяці тому +1

    Thank you so much for this vedio,kindly keep it up sir🎉🎉

  • @sandeepkumar-kx2wj
    @sandeepkumar-kx2wj 2 роки тому +1

    Very nice and good sir ji 👍🙏

  • @surajkumar-ng9dy
    @surajkumar-ng9dy Рік тому +1

    Very nice video

  • @afjalkhan5892
    @afjalkhan5892 Рік тому +1

    Ek no. Sir

  • @yashwantyadav4225
    @yashwantyadav4225 3 роки тому +1

    Sir 35.5 mm 19 mm or 4.75 mm sieve me se konse sieve ke gradation passing ka material lete hai or 3 sieve ka work kya hai.

  • @SanjayKumar-bd9sj
    @SanjayKumar-bd9sj 10 місяців тому +1

    Thank you ❤❤❤

  • @sarveshsharma1252
    @sarveshsharma1252 4 місяці тому +1

    Sir Iagar mourum soil ho isi sieve se krege

  • @vinaygoswami7814
    @vinaygoswami7814 3 роки тому +2

    What about the material retained on 4.75mm sieve. I think it'll affect the field density when we'll perform the compaction test. And on visual identification this soil is looking like susceptible to crush. So in that case we should take different individuals samples and in every new sample we have to increase water content.

  • @awadheshkumar-em3vs
    @awadheshkumar-em3vs 2 роки тому

    Very nice video sir.

  • @swarupchandanandanand808
    @swarupchandanandanand808 Рік тому

    ❤❤❤❤❤

  • @sureshkumarnishad1497
    @sureshkumarnishad1497 7 місяців тому +1

    Sir agar gsb ya wmm ka mdd karna hai to kis hisab se kaun sieve se kitna sample lenge please bataye sir

  • @dkmaurya8720
    @dkmaurya8720 4 місяці тому

    I think temp. Rang as per is code 100 to 110c hona chahiye

  • @anirudhsinghchouhan3619
    @anirudhsinghchouhan3619 Рік тому +1

    Which mould is this? 1000 cc or 2250 cc? Which you tested 3 kg sample

    • @uthuvhking1667
      @uthuvhking1667 Рік тому +1

      Mould to 1000cc ka hai...
      But in respect of rammar of 4.9 kg ka.. 2250 cc ka mould use korna chaiye tha ? As per is code 10074 :1982

  • @Civilow
    @Civilow 3 роки тому +2

    Plz perform liquid limit I wanna learn through u sir plzzz

  • @manjeetkala2264
    @manjeetkala2264 3 роки тому +2

    Please, provide 2nd part field astronomy in survey..
    Our survey exam on 10 April.. Please

  • @situdhankhar7323
    @situdhankhar7323 3 роки тому +1

    Nice sir ji

  • @GauravKumar-sz6vl
    @GauravKumar-sz6vl 3 роки тому +2

    Sir or vedio daliye soil test
    & Aggregate Test

  • @bharadwajpradhan-sg8wo
    @bharadwajpradhan-sg8wo Рік тому +1

    19mm sieve se pass kariye

  • @awadheshkumar-em3vs
    @awadheshkumar-em3vs 2 роки тому +1

    Sir cbr & marshal mix design pr ek video banao

  • @materialtestingincivilengi8683
    @materialtestingincivilengi8683 2 роки тому +1

    Sir sandy soil kya alag method hay kya

  • @007govind
    @007govind 2 роки тому +3

    Sir temperature 105se more than nhi hona chahiye because structural water will be reduced

  • @taranjeetsingh3295
    @taranjeetsingh3295 2 роки тому +1

    Sir site se jo sample collect kiya he usko pahle break krna hota he ya direct 4.75mm se pass krte he

  • @deepaktiwari7072
    @deepaktiwari7072 2 роки тому +1

    Sir plzz railway me kaon kaon se test hote hai uski puri series banaye for QA/QC Civil ke liye thanks

  • @badalkumar6603
    @badalkumar6603 2 роки тому +1

    Sir soil mix glubs pahn k karte hai na , haanth me moisture aa jayega na.

  • @materialtestingincivilengi8683
    @materialtestingincivilengi8683 2 роки тому +1

    Sir sandy soil omc maximum kitna hona chahiye

  • @ASHISHSHARMA-mo5pf
    @ASHISHSHARMA-mo5pf 3 роки тому +1

    On what basis u decide to perform the test using Modified proctor test ???
    Why not standard proctor ??

    • @CivilEngg.ByYogeshKaushik
      @CivilEngg.ByYogeshKaushik  3 роки тому

      That depends upon FQAP of Contractor company & client orders

    • @ASHISHSHARMA-mo5pf
      @ASHISHSHARMA-mo5pf 3 роки тому

      @@CivilEngg.ByYogeshKaushik sir, if any student want to conduct the test in laboratory then is there any criteria based on sieve analysis 20% retained like this for selection of Modified or proctor method?

    • @CivilEngg.ByYogeshKaushik
      @CivilEngg.ByYogeshKaushik  3 роки тому

      Dear it also depends upon the rammer & mould available in laboratory
      If both proctor & modified proctor are available in laboratory then we have to choose as per type of soil on which we want to conduct the test

    • @ASHISHSHARMA-mo5pf
      @ASHISHSHARMA-mo5pf 3 роки тому +1

      @@CivilEngg.ByYogeshKaushik exactly this is what I am looking for, for which type of soil we prefer modified proctor or standard proctor test, please reply with your valuable response

  • @bhupenderchhatria6613
    @bhupenderchhatria6613 Рік тому +1

    But, sir 1000cc p 2.6kg rammer use karna chahiye

  • @VARUN-cn3ke
    @VARUN-cn3ke 3 роки тому +1

    Send me pdf sr

  • @nomadicnirmal5993
    @nomadicnirmal5993 5 місяців тому +1

    1000 cc Mould in used with respect to hammer 2.6kg you are used 4.9kg so your testing is failed

    • @CivilEngg.ByYogeshKaushik
      @CivilEngg.ByYogeshKaushik  5 місяців тому +1

      This is just only for understanding & mould available at site dear

    • @thefreakingyash
      @thefreakingyash 3 місяці тому

      ​@@CivilEngg.ByYogeshKaushikso u must mention it in ur video idiot ....