How to repair Manual BP Machine at home? || Medical Guruji
Вставка
- Опубліковано 9 вер 2024
- How to repair manual BP Machine at home?
Follow us on facebook
/ medicalguruj
Buy BeatO Glucometer
fkrt.it/bKk9GKNNNN
Buy Strips = 1 strip less than 20Rs
fkrt.it/sYpjxnuuuN
How glucometer works?
• Glucose meter kya hota...
For Crazy design and graphics work
Contact Yash parmar - yash.parmar312@gmail.com
Cuff Rubber tubing
www.flipkart.c...!
Bp cuff bulb
www.1mg.com/ot...
Meri bp machine m mercury upar nhi ja rha but cuff m aur fill ho rhi h ...kya problem ho skti h plz reply
Me to
Atisundar bhaiya
How to know the standard level of mercury.. ??
I dont know, how much was dropped, so, how much to refill ??
How to remove the gap in between the Mercury of sphygmomanometer..
Tilt the apparatus to left
It’s not working
Thanks for your help & information.
Good information sir ji thanks for you
If lower volve near tank is not closed after blood pressure check, then murcurey will leaks from uper hole.please tell people to close volve carefully after use
Brother murcury glass tube mein ooper jatay hoey toot ya peices mein ho jata hy hy... is ka hul kia hy...
Beautifully explained d anatomy of sphygmomanometer & how to correct it when it goes wrong...good job ... it's very helpful
Good explain brother thanks
A big thanks to you bro.. Great job
Thank you so much brother... U solved my problem
Must describe mercury leakage at bottom of glass tube.
May i know how much gm/ quantity is required to refill the bp apparatus ?? Please
How to insert mercury
सर आपने बहुत सुंदर जानकारी दी है।हमारे पास भी यह मसीन हैं।दूसरा हमारे पास डिजिटल मशीन भी है जिसका रबड़ ओर मशीन को जोड़ने वाला टूट गया है वो नया कहा से ले प्लीज जरूर से बताए ।
Thanks alot I fixed it 😇
Thanks bro
Super Sir Thank you
how much use mercury in to bp aprater
My mercury had leaked from downside and I had collected all the mercury in a plastic container.can i use the collected mercury or I have to buy new one.
Bohot useful tha
Sir mercury upr jara hai or bina point ko release kare mercury neeche aa raha hai fastly
Hi, where can I find a replacement mercury sphygmomanometer glass tube?
where is the cuff and the cover available in Mumbai. Pls let me know ASAP.
Thanks
Your welcome. Keep watching…
It was nayc
Folding both clamp broken, how it restore
Yes this is my problem please tell how to repair
Thank you 👍
How to air bubbles release.
Sir, Pump karne k bad mercury uper nhi jara
Aesi problem m kya kare plz reply sir its an emergency
पंप या कफ लीकेज होगा कफ के अंदर की प्लास्टिक को बाहर निकालकर लीकेज भाग को फेवीक्विक से चिपका दो
How to repair if mercury is falling too fast
Mercury is not going back to cylinder it stays inside the pipe even after zero pressure...
Thank you sooo much
Good knowledge
For thank you
My bP apparatus showing high blood pressure. 2. Mercury does not stop it falls very fast inspite of not releasing . 3. It can't stand from box. Pl reply.advice
Mercury tank Crack ho gaya to kya ye bhi mil jata hai
Sir good video, can you tell me how much mercy is use in bp machine pls tell me quantity
Good day! Im sorry may i ask how to replace the leaked mercury. i used it earlier to my aunt but suddenly it was leaked.please teach me how to replace the mercurt in english.thank you
thank u bhai
I have medisan bp machine . It shows error 3 ie cuffs don't inflate . Can this repaired ?
Kitane ml para dala jaata hai
Sir .. Mercury disconnected ho gya h bubble show ho rha h usme ..kya krun
Kha par melage markare bhai jalde bata na
mercury on off knob ko kaise replace krei? kindly inform
How to calibrate bp apparatus..plz tell me in detail...
Does Indian flights allow sphygmomanometer?
Bp oprator me kitna gr mercury lagta hai.
Hinge joint is broken.. how to repair it?
Jo mercury tank me rubber hota hai wo damage ho jae to milta hai ya nahi. Pls. Reply sir🙏😌
BP check krne par apne aap mercury upar se niche aata hi kya problem hai sir
Kanch ki nali ke upr ka pench nahi khul rha kaise khole
Nice me nurse hoon
Sir meridian machine slam nacho kar raging h
Sir humare bp machine me mercury ..upar nahi ja Raha sirf 40 ..60 tak hi ja raha bp lete waqt ..kaise theek kar sakte hai batay ..
How we can fill mercury in tank
If there's bubbles in mercury glass how to remove bubbles
Why do handcuff not fully expelling the air, after complete realise also its shows reading 40 etc , Its giving false reading ,
بھائی جان السلام علیکم ، اگر نلکی کے اندر مرکری چھوٹے چھوٹے ٹکڑوں میں تقسیم ہو گئی تو اس کو کیسے ٹھیک کر سکتے ہیں ،جواب دیے کر شکریہ کا موقع دیں
My glass tube is broken and mercury is leaked
What amount of mercury is needed to refill and from where to purchase it.(mercury and glass tube )???...
Thanks for this information. I want to know one thing that when we pump, the mercury does not go up, suddenly the Mercury goes up, please tell us solution.
brother murcury ooper jatay hoey toot chhotay barray peices ho jata hy...
@@najamfarooqi8982 I HV a same problem
Bp machin dimond ka hai banana hai
Kaise banega
nice
There are gaps in mercury column and its leaking how to fix the problem
Meri b. P. Machine ki pump karne par merucy up nahi ho rahi to kya karna h belt me bhi air fill ho rahi but merucy up nahi ho rahi h
Plz reply mujhe bhi yahi problem h
Tnq
Mere aprats main mercury jb uoper ko nikalts hy to us main air spaces nzar ati hen yani mercury divide huwa hota hy
Ham are pass ek Diamond bp mercurial machine hain, jo kam nehi karl raha.
Please tell me what can I do.
Velcro removed from the HAND BP MONITOR CUFF , pls. let us know how to paste Velcro on the cuff
Babal q bante hn sir mercury tube mai jb hm bp chack karte hn.wo kese khatam ho ga
Agr is ka marcery up down ho jy to kia karain
how we insert mercury in it
Mere BP me pressure deta hu to para uper nahi jata h Kya Karan h batao
Bhai humko glass chiyehiye
Kaise milega aap ke pass se
Mercury mei air gap aa gaya hai.. How to fix that?
Iska para change hota h kya
Mercury do part me dikhe to kya kare
Normal Mercury daal sakte h kya?
how do i know the adequate quantity of ḿercury' to fill in the apparatus?how much ml/mg to fill?
Aneroid sphygmomanometer ka re -caliberate kesse Kare?
Namaskar sir, mere set me jab pump krte h to kafi jor lagta h,100-110 k baad jyada jor nhi lagta,kya krun ?
Sir mera lid jo hai vo case se alag hogaya hai...abhi kya kar sakte hai
Sir mere bp apparatus ma pump karne se murcury up nhi horaha ha agr ho b raha to ek dum se down hojata ha ka problem hosakta ha
🙏🏼🙏🏼🙏🏼🙏🏼
Bhai marcary price
Mercury cut cut ho ja raha thik kaise kare sir
Sar mere BP set mein para bahut mushkil se upar chadhta hai baar baar hawa bharane per bhi bahut Jor lagana padta hai kya Karen
Wrong reading how can solve, what is the cause?. Same person getting wrong result in my side but hospital its coming diffrent
Sir mere BP machine me mercury bhi gir gyi kitna kharcha aayega?
Sir pressure apply krne ke bad ...almost 40/50 reading se hi Mercury rise kr rha hai...isliye biht tight ho jta hai cuff...koi solution???plz🙏🙏🙏
how many ml mercury it needs if all mercury is wasted,p
Reply pls above Question
You need to fil untill it comes to the top of tank
Lekin mera kharab h para wala
A small amount of mercury liquid is leaked into glass tube …..how to push back into container?
Kitna mercury dalni hai
Bro... What if my mercury comes down halfway while filling air pressure?
Refill mercury
Excellent explanation bhayya, please inform me why bubbles are coming in the vertical glass tube in mercury.
Sir no monitor wale mercury ko touch krne se kuch Problem ho skti h kya ? Plz help sir
Samaj nahi aaya apka question
@@Medicalguruji sir bp monitor k Mercury ko Maine Galti se touch kr liya tha.
Kya us se kuch problem ho skti h plz sir mujhe bht tens ho rhi h
@@Medicalguruji sir Maine bp check krne wale mercury ko touch Kiya h...kya us se kuch problem ho skti h
Digital BP machine mai kya kya problem aa skti hai aur repair kese kre aap bta do please
Brother today I bought a elko mercury manual BP machine but it doesn't pump the cuff and mercury not lifting up.Please tell me the solution or it a damage one. I also on the pin
Check mercury level. If there is no mercury get it replaced.
Thanks Brother it solved , I had not connected the cough pipe to the mercury pipe.but its first time for me so very difficult for me to release slowly the pump key.
when i release rubber ball valbe slowly I hear a very very slow dhak Dhak sound and after decreasing 5 points I hear a clear Dhaka dhak sound ,which one I have to count very slow or clear dhak Dhaka sound number?Please tell me bro. And which hand is better for measure? Suppose I missed to hear the sound while releasing valve at a certain point, can I again pump for recheck. Thanks
Sir puump bahut zyada tight chal rha ,or murcury levil nhi badha paa rha h bahut tight chalkr levil Aata h
Mera BP instrument m BP cuff infalat hone k Baad wapas deflat nhi ho rha
Pump k andar ka system kaise set kare khul gya h