evaluate the height of a chimney to produce a Statics draught of 15mm of water column. the temperature of the gas in the chimney is 270 c the barometric reading is 760mm of hg. the value of r of air and gases may be taken as 0.287 and 0.255kj/kgk
Please explain jharkhand boe 2016 paper2 Qn.4 A boiler is equipped with a chimney 25m high.the temp.of outside air is 25*c and average temp. Of flue gases in the chimney is 320*c.if the boiler is supplied 20kg of air per kg of fuel burnt.calculate. 1.the theoretical draft created in cm of water and 2.the velocity of flue gases in the chimney if 60% of the draught is lost in friction at the grate and passage
Sir mai bolier ke bare me kuchh nahi janta hu abhi power plant me join kiya hu wha whrb boiler hai mai apke channels ki video dekhta hu but kuch kuch chije samajh nahi aa rhi mai confuse hu ki start kya se karu please help sir 🙏🙏
sir me boe ki taiyari kar raha hu ye 2023 me gujarat boe me puchha gaya tha iska solution dijite plz Q.3(A): Following readings are noted from a power plant Cooling Tower: Cooling water flow: 1500m3/hr. Cooling water inlet temperature: 38*C Cooling water outlet temperature: 30*C Wet-bulb temperature: 27*C Dry-bulb temperature: 45*C TDS of cooling water: 1500ppm TDS of make-up water: 250ppm Evaporation loss: 2% If Windage loss is negligible Then Calculate: (i) Approach, (ii) Range, (iii) Heat load of the cooling tower (iv) COC (Cycle of concentration), (v) Blow-down, (vi) Make-up water required
Que : A chimney is 28 mtr high and the temperature of hot gases inside the chimney is 320 c and the furnace is supplied with 15 kg of air per kg of coal burnt. Calculate a- Theoretical draught in mn of water b- Draught head in meters of hot gasaes passages....please solve it🙏🙏
Bahut hi easy method ,good Sir .
evaluate the height of a chimney to produce a Statics draught of 15mm of water column. the temperature of the gas in the chimney is 270 c the barometric reading is 760mm of hg. the value of r of air and gases may be taken as 0.287 and 0.255kj/kgk
chemicals derived form coal? Coal se kaun sa chemical banate hai
Sir high temperature se turbine exeal thurst increases hota h kay
What is monoblock water pump? Pls brother discassion.from w. b.
Sir,please make video about coal dry & cooling plant(cdcp)
Sir,plz explain why turbine release load due to higher National Gride frequency
Flue gas velocity at various zones ka baare me ek video banavo sir
Sir Boiler Drawing ka upar video banaaiye.
Please explain jharkhand boe 2016 paper2 Qn.4
A boiler is equipped with a chimney 25m high.the temp.of outside air is 25*c and average temp. Of flue gases in the chimney is 320*c.if the boiler is supplied 20kg of air per kg of fuel burnt.calculate.
1.the theoretical draft created in cm of water and
2.the velocity of flue gases in the chimney if 60% of the draught is lost in friction at the grate and passage
Sir mai bolier ke bare me kuchh nahi janta hu abhi power plant me join kiya hu wha whrb boiler hai mai apke channels ki video dekhta hu but kuch kuch chije samajh nahi aa rhi mai confuse hu ki start kya se karu please help sir 🙏🙏
Pleasase make video on engineering drawing which were asked in BOE exam
Thanks for information
Rajasthan Boe ke or questions bhi solve kr dijiye sir
sir me boe ki taiyari kar raha hu ye 2023 me gujarat boe me puchha gaya tha iska solution dijite plz Q.3(A): Following readings are noted from a power plant Cooling Tower:
Cooling water flow: 1500m3/hr. Cooling water inlet temperature: 38*C
Cooling water outlet temperature: 30*C Wet-bulb temperature: 27*C
Dry-bulb temperature: 45*C TDS of cooling water: 1500ppm
TDS of make-up water: 250ppm Evaporation loss: 2%
If Windage loss is negligible Then Calculate:
(i) Approach, (ii) Range, (iii) Heat load of the cooling tower (iv) COC (Cycle of concentration),
(v) Blow-down, (vi) Make-up water required
Que : A chimney is 28 mtr high and the temperature of hot gases inside the chimney is 320 c and the furnace is supplied with 15 kg of air per kg of coal burnt. Calculate
a- Theoretical draught in mn of water
b- Draught head in meters of hot gasaes
passages....please solve it🙏🙏
Next wale sum k..42.4 mtr ..ans h ky?
Gujarat BOE 2023 paper-1 ka question no.4 ka solution karvaye
SIR...... STACK MONITORING CALCULATION KA VIDEO BANAIYA NA PLZ
Sir boiler maintenance ka bara sa video banyo
plz solution all boe peper ( 2010 to 2022) all syllabus basis
Small. h 30 it's ambient. Temp