  • Hello friends, welcome to join the engine generator channel youtube. Thank you very much for watching my video, share ~ like ~ comment & subscribe.
    For my video this time about portable generator capacitors & the main causes of frequency / Hz not coming out.
    So if you want to replace the capacitor with a larger size, you can try it with a note that your generator is made by a well-known product.
    If Your Generator Set Is Regular Type, I Suggest Don't Try It. Because the ordinary generator does not match what is written, such as 500 watts. Now the output power that will come out will not reach 80% of the installed power.
    If you want to try it, don't forget to pay attention & check the resulting frequency.
    If your generator has changed - replace the capacitor but the Hz still doesn't come out, there is a big possibility that there is a problem with the generator / dynamo.
    Ok friends, that's all from me, hopefully useful. Don't Forget to Share ~ Like ~ Comment & Subscribe.
    If There Are Friends & Relatives Who Have Portable Generators That Still Use a Capacitor System Share This Video Link, Hope It Can Be Useful.

КОМЕНТАРІ • 60

  • @mikowardana1217
    @mikowardana1217 8 місяців тому +1

    Saya ada genset 2 tak 950 watt, setelah kemarin bermasalah akhirnya ganti capacitor persis yg ada di video warna orange, ketika saya cek volt normal di 220 tapi hz naik sampai di 100 lebih, apa capacitor yg menjadi penyebab masalahnya, mohon solusinya om, biar aman alat elektronik saya🙏

    • @enginegenset86
      @enginegenset86  6 місяців тому

      Coba ganti kapasitor dengan nominal UF yg lebih kecil

  • @ordinary_people519
    @ordinary_people519 Рік тому +1

    Om gimana nyetel hz pada genset honda om tolong jawab

    • @enginegenset86
      @enginegenset86  Рік тому

      Tinggal Naikan Atau turunkan Rpm mesin ( setel Gas ). Tp klu Kapasitor sudah pernah di ganti dan wktu ganti tdak sesuai Spesifikasi, gak Bakal Ketemu Hz nya ( Acak )

  • @sintasound4157
    @sintasound4157 2 роки тому +1

    Klo modif generator 5 kva gimanaas

    • @enginegenset86
      @enginegenset86  2 роки тому

      Di sesuaikan sja sama spesifikasi mesin ( itu pkai mesin yg GX type brpa ) klu GX 390 / 420 Bisa

  • @didifilm9823
    @didifilm9823 Рік тому

    tanya mas genset saya 3500 watt vol keluar hz cuma 1 kira2 yang rusak apanya mohon jawabanya maap pemula terima kasihh

  • @alanmiswar
    @alanmiswar 3 роки тому +1

    Tanya Mas, Apa Efeknya dari pemasangan Kapasitor Standar Bawaan Pabrikan dan di pasang lgi kapasitor ukuran lebih tinggi dari pabrikan, dipasang Paralel untuk 1 Genset ...

    • @enginegenset86
      @enginegenset86  3 роки тому +2

      Klau sistem pararel seperti itu , klu genset anda merk dari produk ternama masih bisa ( tetapi mengurangi Usia Lapisan kumparan ) krna klu kapasitas kapasitor yg melebihi standarny apalagi di tambahkan 1 lg pasti kumparan akan cepat panas dan Lapisan Sirlaknya Akan Meleleh / terkikis , itu sama saja memaksakan Dinamo ( Generator ) .
      Klu genset anda Produk Kaleng kaleng yg harga Murah Jangan Di Coba , biarkan Seperti bawaan pabrikan . Memang daya mampunya hanya sebatas itu

    • @alanmiswar
      @alanmiswar 3 роки тому +1

      @@enginegenset86 Di Copy lgi Ilmunya mas, Terimakasih idukasinya sangat membantu. . . Semoga cenel ini makin ramai. Jgn lupa suskrep cenel ini (Note : bagi yg baca) jgn lupa nyalakan loncengnya . . 😄😁

    • @enginegenset86
      @enginegenset86  3 роки тому

      Ok trims👍

  • @varroereergasi9512
    @varroereergasi9512 3 роки тому +1

    Om mau tanya genset saya suda avr 2000w. Coba saya hidupkan volt 227 tp hz nya 55 jika dikasih bebann lampu led 3 10watt kok di panel hz nya malah naik sekitar 80hz. Tp coba saya kasih beban pompa air malah turun di 47hz. Trus coba saya cek menggunakan avo digital yang ada hz nya tanpa beban volt masih 226 tp hznya ga bisa kebaca di kisaran 200hz naik turun scara cepat g bisa ktmu 50 hz. Dan pernah saya coba saya seting volt 220 hz nya 52 tp saya hidupin pompa air malah drop di 190v dan 33hz.
    Mohon solusinya om🙏

    • @enginegenset86
      @enginegenset86  3 роки тому

      Drop 190V dan Hz turun sampai 33Hz , Brarti itu kan Drop semua Baik HZ & Volt . Anda sudah mencoba Seting Tegangan Volt , Apakah Anda Sudah Cek pada Bagian Mesin ??? Mesin jg memiliki kapasitas Daya Mampu , Apakah Asupan bahan Bakar yg masuk ke dlam ruang bakar Sudah mencukupi ???
      Permasalah Genset Anda jg Bisa dri Karburator Kotor & Governor Automatis Gas Bermasalah . Coba Bersihkan Karburator Dlu + Setel karburator , jika hasilny ttap bisa jg permasalah pd bagian Governor Automatic yg menaikan & Menurunkan Gas nya bermasalah

    • @enginegenset86
      @enginegenset86  3 роки тому

      Sya kasih gambaran simpel sja , anda punya motor biasa buat naik tanjakan mampu tenaganny sama sekali tdak turun , kemudian 3 bulan lg anda gunakan naik tanjakan yg sama di situ motor anda tiba2 tdak mampu naik .
      Jd coba anda Cek dan bersihkan karburator + Anda Seting .
      Klu tidak Bisa setel & Bongkar karburator , panggil saja tukang servise

  • @dexleedarius7732
    @dexleedarius7732 3 роки тому +1

    Kalau frekuensi 52hz semasa enjin running bahaya atau tidak? Apa kesan yg jadi?

    • @enginegenset86
      @enginegenset86  3 роки тому

      Engine Runing Frequensi 51Hz ~ 52 Hz Sebelum Menerima Beban , Pada Saat Engine menerima Beban . Perhatikan Frequensi Turun/Droop Sampai Berapa Frequensinya .
      Jika Frequensi 52 Hz Turun Menjadi 51Hz Pada saat Menerima Beban , Kamu Bisa Menurunkan Frekuensinnya menjadi 50 Hz Jika Di gunakan Untuk Alat Elektronik .
      Jika di gunakan untuk Menghidupkan Mesin Bor ~ Gerinda , Frequensi 51 Hz Tidak Apa

    • @dexleedarius7732
      @dexleedarius7732 3 роки тому

      @@enginegenset86 tapi ini semasa enjin Ada beban frekuensi 52hz

    • @enginegenset86
      @enginegenset86  3 роки тому

      Turunkan Saja Frequensinya , kalau Frequensi 52Hz jika Alat - alat electronik yang Anda Hidupkan di dalamnya Terdapat IC maka Akan cepat Rusak , Karena IC & Processor Harus Bekerja Pada Volt & Hz Yang sudah Di tentukan Dan Itu harus Bersifat Stabil Untuk Volt & Hz ( Tidak Boleh Naik Turun )

  • @sukucahayachanel8903
    @sukucahayachanel8903 3 роки тому

    Kalau ukuran kapasitor di perbesar turunkan rpm mesin,kalau rpm sama seperti yang ada volt akan naik melebihi batas dan dinamo pasti panas

    • @enginegenset86
      @enginegenset86  3 роки тому

      Iya betul , tetapi klu Rpm turun maka Hz ( Frequensi ) jg akan ikut turun

    • @sukucahayachanel8903
      @sukucahayachanel8903 3 роки тому +1

      @@enginegenset86 ya disesuaikan lah pak...kalau dibawah 50 hz masih aman kalau di atas itu sudah mulai berbahaya karena alat listrik Indonesia batas umum frekuensi 50 hz.misalnya kapasitor diperbesar rpm tetap otomatis frekuensi naik itu akan membahayakan bagi alat listrik terutama alat elektronik

  • @jagumane4995
    @jagumane4995 3 роки тому +1

    सर....जी.. वेल्डिंग जनरेटर-अल्टरनेटर ...के आर्मिचर और फिल्ड के कनेक्शन डायग्राम दिखावो.....???? वेल्डिंग अल्टरनेटर

    • @enginegenset86
      @enginegenset86  3 роки тому

      hello friends, Sorry I don't have a schematic diagram of the welding generator

    • @jagumane4995
      @jagumane4995 3 роки тому

      @@enginegenset86 Sir..Ok.

  • @Nartacahndeso
    @Nartacahndeso 3 роки тому +1

    Berapa harganya yg merah itu bos..?

  • @kenzofarm6269
    @kenzofarm6269 3 роки тому +1

    Bang kalau boleh bertanya.. Genset buat pompa udara/aerator kolam kok ndak bisa kenceng semburan nya.. Kira kira genset rusak nya dimana ya bang

    • @enginegenset86
      @enginegenset86  3 роки тому

      Coba lihat HZ nya pak Pakai avometer , klu volt memang terbaca 220 volt . Tetapi Frequensi / HZ belum tentu , jd cek dlu HZ nya ( 50 HZ )

    • @kenzofarm6269
      @kenzofarm6269 3 роки тому +1

      @@enginegenset86 cara ngecek selain pakai avometer gmna pak soalnya ndak punya hh

    • @enginegenset86
      @enginegenset86  3 роки тому

      Gk bisa pak harus pakai avometer untuk Lihat HZ , coba mnta tlong teman sja barang kali ada yg punya

    • @kenzofarm6269
      @kenzofarm6269 3 роки тому +1

      @@enginegenset86 kalau menaikan HZ nya yg sebelah mana ya pak. Genset saya merek general 1200watt

    • @enginegenset86
      @enginegenset86  3 роки тому

      Rpm Mesin jika di Naikan maka HZ Akan ikut naik

  • @heriadi2116
    @heriadi2116 2 роки тому

    Sy punya genset 3 Pase 40 kw pake avr .voltase ada tp hz tdk ada.ap nya yg bermasalah ya bg.

  • @afifputra6284
    @afifputra6284 3 роки тому +1

    Mas punyaan saya yamaha ef6600 keluar arus tp gak normal kira" apa nya ya

    • @afifputra6284
      @afifputra6284 3 роки тому +1

      Kalau boleh minta no hp nya

    • @enginegenset86
      @enginegenset86  3 роки тому

      Sya msih ad pkerjaan di pulau sinyal susah

    • @enginegenset86
      @enginegenset86  3 роки тому

      Itu masih mengunakan kapasitor atau sudah sistem Avr ?

    • @enginegenset86
      @enginegenset86  3 роки тому

      Yg tidak normal itu Rpm mesin naik turun atau voltasenya yg naik turun ?

    • @afifputra6284
      @afifputra6284 3 роки тому

      @@enginegenset86 AVR MAS

  • @ipunkario992
    @ipunkario992 3 роки тому +1

    Lur boleh minta WA nya 🙏🏻 buat shering

    • @enginegenset86
      @enginegenset86  3 роки тому

      Sharing sini aj Mas , Nanti buat teman2 yg lain yg mengalami permasalah sperti yg mas Alami . Bisa lngsung lihat Chat

    • @enginegenset86
      @enginegenset86  3 роки тому

      Kita di sini tujuanny Hanya untuk berbagi Pengalaman , krena Troubleshooting itu Bermacam macam . Mngkin di antara Teman2 yg lain Punya pengalaman yg lebih dri sya , siapa tau jg bisa kasih Solusi

    • @ipunkario992
      @ipunkario992 3 роки тому +1

      @@enginegenset86 siap 86 komandan

    • @ipunkario992
      @ipunkario992 3 роки тому +1

      Lur bagian exhaus manifol sampe ke turbocharger genset membara saat beban puncak,
      Kalo bleh tau penyebabnya pa saja dan perbaikan nya ? Man tau ada rekan" yg lain mengalami nya, untuk dapat di shering 🙏🏻

    • @enginegenset86
      @enginegenset86  3 роки тому

      Mesin apa ? Brapa Kw ? Type V atau inline ?