Flexural Strength of Tiles

Поділитися
Вставка
  • Опубліковано 31 січ 2025

КОМЕНТАРІ • 11

  • @pradeepsm5833
    @pradeepsm5833 2 роки тому +1

    Well explanation sir 👏🙌

  • @carljustinealviar5809
    @carljustinealviar5809 Місяць тому +1

    sir do you a pdf or design plan specification of the machine? 😊

  • @dlandofdeepu3415
    @dlandofdeepu3415 Рік тому +1

    How does 2.25 had become thickness. The thickness is 22.5 in mm. Please check in flexural strength box

    • @ramarathnam
      @ramarathnam  Рік тому

      The thickness of the tile is 2.25 mm only
      It was a small tile

  • @anirbanmaiti792
    @anirbanmaiti792 3 роки тому +1

    What about the Lever Arm Constant, is there any ?

    • @ramarathnam
      @ramarathnam  3 роки тому

      It deals with calibration of the loading frame.
      Will try to post about the effect of lever arm by the loading frame in some other lecture.

  • @mundaneer7860
    @mundaneer7860 3 роки тому +1

    Can I ask some question?
    1. I have read somewhere at a document regarding the rate has a unit of N/mm2/s for breaking strength or flexoral strength. Can you enlighten me on this?
    2. Is there a required weight of the metal in the supporting rods and the rod with the load cell?
    I hope you can help with this. I am a newbie. Thanks!

    • @ramarathnam
      @ramarathnam  3 роки тому +1

      Flexural strength is represented by N.mm²
      Rate of application shall be represented by stress/time N/mm²/s
      No load cell attachments are there
      The weight of lead shots collected in the bucket below the loading platform is weighed to calculate the breaking load

    • @mundaneer7860
      @mundaneer7860 3 роки тому +1

      @@ramarathnam Thanks!