Tutorial 11 : STIFFNESS MODIFIERS FOR CRACKING OF STRUCTURAL ELEMENTS AND EFFICIENT INTERNAL ACTIONS

Поділитися
Вставка
  • Опубліковано 11 гру 2024

КОМЕНТАРІ • 29

  • @sreejithsreekanth1369
    @sreejithsreekanth1369 2 роки тому +1

    There is only one word for this video :- awesome.👍

  • @yogeshshakya9558
    @yogeshshakya9558 3 роки тому +1

    Such a good Tutorial Series Sir. Please upload more videos, it was a beautiful series.

  • @Aussie_Engineer
    @Aussie_Engineer 6 місяців тому

    Great explanation, sir please do one full high-rise building analysis and design.

  • @azmat_waseem
    @azmat_waseem 2 роки тому +1

    Very Informative... Thank you...

  • @FahimKhan-xv4vb
    @FahimKhan-xv4vb 3 роки тому +3

    Thank you sir for useful explanation

  • @Darshit_7
    @Darshit_7 3 роки тому +1

    Thank you sir
    for explaining in very simplified manner

  • @JaspreetSingh-dj3mk
    @JaspreetSingh-dj3mk 3 роки тому +1

    Easy explanation sir....

  • @swastikpoojari7526
    @swastikpoojari7526 3 роки тому +1

    Thank you sir for such a great explanation👍

  • @deep746
    @deep746 3 роки тому +2

    Thank you so much, very will explained
    Please make a video for transfer beam design in etabs

  • @fazalarju
    @fazalarju 3 роки тому +2

    I request you to kindly make a video on design of shear wall and to find out reinf in boundary element. I will be very much grateful to you.

  • @Hanns_designs
    @Hanns_designs Місяць тому

    For serviceability checks should we use crack or uncracked section?

  • @azmat_waseem
    @azmat_waseem 2 роки тому +1

    Sir, what about tutorial 10? not in the list???

  • @vasubhadania
    @vasubhadania 9 місяців тому

    I have a doubt
    What will be the stiffness modifier for retaining wall...!?

  • @aldiputra9236
    @aldiputra9236 10 місяців тому

    Sir, how we determine reinforcement in side rebar of raft foundation. Thank you

  • @nirbhaymishra4371
    @nirbhaymishra4371 4 місяці тому

    Sir according to IS1893 What modifier should be adopted for serviceability(drift check, ) check for building height less than 50m like G+10.

  • @dr.manmohanmaniyar6985
    @dr.manmohanmaniyar6985  3 роки тому +1

    Dear All,
    I am pleased to announce the course as mentioned in tutorial 10. The course will cover all the topics mentioned in the video through a series of lectures. Live lectures will be delivered every Saturday for 1 hour between 5:00 pm to 6:00 pm ( 10 lectures). Video link of recorded training will also be shared in next 2-3 days after the lectures. Q&A session will be conducted in the 10th lecture. A certificate will be issued on completion of the course. Fees for this cource will be INR 20000/-. +3600/- GST. ( Total fees INR 23600/-) Fees to be deposited in advance in bank account as mentioned below :
    Manmohan Maniyar
    ICICI current bank account No. 001905004904
    IFSC Code ICIC0000019
    Please email details of bank transfer to man.maniyar@gmail.com
    First lecture will start on 11 September 2021.

  • @FaizanShaikh-xd7bo
    @FaizanShaikh-xd7bo 3 роки тому +1

    can stiiffness modifer be give to torrsion in beam as 0.35 for strength model

  • @Zorot99
    @Zorot99 Рік тому

    Sir can I apply the same factors using bs8110 design code?

  • @ChinTanLimbani
    @ChinTanLimbani 3 роки тому +1

    First thanks for the video sir....
    in Column if Moment of Inertia is reduced for Bending only than why for Shear Wall it reduced for Axial (Membrane) direction? (As both are same type of load carrying system)

    • @pulkitvelani
      @pulkitvelani 2 роки тому

      Membrane is not axial. It is out of plane. And we want to design wall only to take load along length/inplane direction. Hence, 0.01 for mxx.

  • @mansoorAli-pp9do
    @mansoorAli-pp9do 3 роки тому +1

    Ty sir.
    Qn: is it ok if i use scale factor of service model(eqx/specx) in ultimate model for analysis and design or i have to scale model in sls and uls both.
    Qn 2: what will be the modifiers for spandrals?

    • @dr.manmohanmaniyar6985
      @dr.manmohanmaniyar6985  3 роки тому

      Q1. Yes, scale up for both.
      Q2. Spandrels are flexural elements like beams. Use appropriate modifiers numbers for beams for f11, f22 & f11.

  • @fazalarju
    @fazalarju 3 роки тому +1

    Sir, as I understood we can also use stiffness modifier as per IS 16700 2017 even for the bldg of height less than 50 m
    Pl confirm yes or not sir