भाई जो आप ये MCB उल्टा लगा रहे हो ना वो गलत है । आप का समझाने का तरीका बहुत अच्छा है । भाई में भी electric काम करता हु । और मैने दो साल election कंपनी में काम कर रखा है । वहा पर जब mcb बनती है तो वो फेस नीचे की तरफ के लिए ही mcb को बनाया जाता है । काम तो वो करता है पर बहुत से टाइम पर वो ट्रिप नही कर पता है । ओनली RCCB को ऊपर से नीचे की तरफ लगाया जाता है ।
Nice information to detect fault. Lekin sir mcb connection me pin type lug use karni chaiye. Aur mcb busbar lagaiye. looping nhi. Tape ke jagh hum cable tie use karna chaiye.. Aur for leakage current use of RCCB.
Wao very very nice bhai jaan ap nay to kamaal hi kr diya hay bhai jaan ap nay bohat assan or khub achay tareeqay say hamaiyn sajaya hay ap ka bohat bohat shukariya. Ummeed hay k ap isi tara ki mazeed hamain gaednis datay rahain gay
Bhai sach bataun to itne acche se mere ustad bhi mujhe nahin sikhate hain jitne acche se aap sikhate ho aur aapki har ek baat mujhe samajh mein aati hai aap bahut tarkki karo 🫂🫂💞💞💞💞
Bhai jab bhi fault hota hai to MCB niche ko taraf hi girti hai Internet pe MCB ki working dekh lo Electromagnet MCB ko niche ki taraf karta hai fault hone pe Aapne Jo lagaya hai usse to achha tha ki MCB na lagake direct wiring hi kar dete MCB ke paise bhi Bach jaate
ITI students please follow the data sheet of MCB which direction MCB or RCCB should be connected. Now a days DB should be connected with proper RCCB and surge arrester. MCB have over current and short circuit protection and RCCB have leakage current protection. You should do wiring with proper ferrules, wire ties and connecting links. There should be double earthing in the DB. What I mean to say just like that you can't do wiring. You should follow the safety.
Pahle MCB kam kese krta hye sir vo ap dekhlo....or tar upr se hi lagta hye q ki MCB ko dhayan rakte huwe .. Or neutral tar.. K liye wala MCB box me canectr laga rahta hye sir... Or tar niche lagane se MCB sahi tarike se kam nahi kr pata....thankuu sir itna batane k liye
Ek baat aur Bhai aapne jo kaam UA-cam ke jariye Kiya teach karne ka kaam ye koi bhi nahi kar raha apne pure imandari se . Thanks brother
सर मैं आपसे पूछना चाहता हूं एमसीबी का उल्टा किए हैं एनसीबी सीधा गिरेगी या उल्टा नीचे की तरफ गिरेगी या ऊपर की तरफ
13:13
Ruwii
सर में समझ गया आप बहुत अच्छा से समझा रहे है** सर आप उल्टा कनेक्सन कर रहे थे और हम फोन को उल्टा कर के उसे सीधे में कन्वर्ट कर लिए✍️✍️✍️
हर रूम मे Ac है तो ग्राउंड वायर डाला ही नही आपने Ac के लिऐ अनिवार्य होता है ग्राउंड bahar sar
Bat to sahi hai bhai
😂😂Waah
Tumra nam bhi😂😂 1 number
भाई जो आप ये MCB उल्टा लगा रहे हो ना वो गलत है ।
आप का समझाने का तरीका बहुत अच्छा है ।
भाई में भी electric काम करता हु ।
और मैने दो साल election कंपनी में काम कर रखा है ।
वहा पर जब mcb बनती है तो वो फेस नीचे की तरफ के लिए ही mcb को बनाया जाता है ।
काम तो वो करता है पर बहुत से टाइम पर वो ट्रिप नही कर पता है ।
ओनली RCCB को ऊपर से नीचे की तरफ लगाया जाता है ।
Bhai me smjha nhi upar phase lgaya hai aur niche se output liya hai kya ye glt hai
@@abh08ac agar kuch fault banega to MCB trip nahi hogi
Thankyou bhai aap video bahut Achcha banate ho
Kya haal hai Bhai
ItI Walo ke liye Ye Videos Banane ke liye thx
Suraj Vishwakarma
Bhai aap ki video mere ko bahut samajh mein I thank you
.😊@@surajvishwakrma9555
Bahut acchi tarike se bataiye aap thank you bhai Suraj electrician
Ok
#electricuanbalaji
Bhaiya aapne UA-cam par batane ka jo kam kiya hai ye bahut hi aacha kam kiya hai aap ne
बहुत ही अच्छे और सरल तरीके से समझाया है, इसके लिए thanks.
लेकिन इसी बाक्स मे अर्थिंग का कनेक्शन भी होता तो अच्छा होता.
Love you bhai
Bohut zabardast bohut asan tarike sey samjaya
Assalam alekum bhai bahot badeya samjai appne aap ke bahot tarskhe jo duva hai hamare alha se
Yes Sir Super Nice 👍
बहुत बहुत धन्यवाद भाई 🙏🙏🙏
बहुत ही अच्छे से समझ में आ गया 😀
Hello bro kaise ho
सरजी नमस्कार.. बहुत मार्गदर्शन.फायदे मंद वीडीओ बनायी है.. ❤❤❤❤
Mashaallah bhai 🥰 jaan Allah aap ko salamat rakhe 🤲🇮🇳
Nice information to detect fault.
Lekin sir mcb connection me pin type lug use karni chaiye. Aur mcb busbar lagaiye. looping nhi. Tape ke jagh hum cable tie use karna chaiye.. Aur for leakage current use of RCCB.
बहुत ही अच्छा समझाया भाई।
Thanks bai..apki video muje bot help krte hai....me kamm sekh rha hu...🙏🙏🙏🙏
Great ful video
Wao very very nice bhai jaan ap nay to kamaal hi kr diya hay bhai jaan ap nay bohat assan or khub achay tareeqay say hamaiyn sajaya hay ap ka bohat bohat shukariya. Ummeed hay k ap isi tara ki mazeed hamain gaednis datay rahain gay
Your Explain ka tarika is very nice Brother 👌👌👌
Kya haal hai Bhai
Lovely bro
You are good teacher
Va guru mast video full samaj m a gaya ase hi video bante rahe 🎉🎉
Very nice Bhai....bahut ache se samjhaya....ek hi baar mein samajh aa gaya....
Sir , m aapki video dekhkar light kaam sikha hu. V aap ki new video ka intezar rahata hai thank you sir
Nice video electric se sambandhit esi tarah banate rahe
Mashallah aap bahot acche se samjhate ho bhaijaan ❣️
Bhai sach bataun to itne acche se mere ustad bhi mujhe nahin sikhate hain jitne acche se aap sikhate ho aur aapki har ek baat mujhe samajh mein aati hai aap bahut tarkki karo 🫂🫂💞💞💞💞
Very useful video sir.i watch your video sir I am Taminadu.india
Wayar n ghuse to dat se khicj ke dhukaye
Dhanyavaad sirji... Superb post video .....!
I love bro 🤣💓
Love you too ❤
Good bhai bahut achcha
Wow kya dimaak chalaya h aap ne samjane ke liye amazing
Thank you for this easy mode video
Waaw ! Masha Allah! Very nice Sir information about yourself
Bhai aap bahut acche se samjhate ho
Thank you sir very good explain keep it up
Bhai jab bhi fault hota hai to MCB niche ko taraf hi girti hai
Internet pe MCB ki working dekh lo
Electromagnet MCB ko niche ki taraf karta hai fault hone pe
Aapne Jo lagaya hai usse to achha tha ki MCB na lagake direct wiring hi kar dete
MCB ke paise bhi Bach jaate
Kya bat bhai
Love you Sir♥️♥️
Good information i like your video my Friend's 👉🔔🔔🔔👌👌👌
Wow. You r explained it very nicely. Thanks bro
Bahut khoob bahut khoob kiya baat hai
Love from Assam ❤
Great work big lk 👍👍👍
4 kya 8 ghus jayege wsyar kamjor na ho to
Sir this video is very important for us
Me aap ki adiktar Video dekhta huu
Aap to bahut acche se bata Diye bhaiya
So super 🎉 your videos sir ji 🎉🎉🎉🎉❤❤❤❤❤
Han video ka bhai aap ko like karte
Bhot atcha video bhai
Bhot assn h maine isse behtar DB dressing kr sakta hon
Mast videoa amir bhai
Thanks Bhai aapko bahut bahut shukriya 🎉🎉
Good Information provided by you
well explain
Kya haal hai bro
Very Very nice sir
Thankuu sir ❤
Me Bhi video banata hu
Nice sir main dev
Mujhe bhi wayring sikhana hai . Please help me bhi .
Ok dekhe
#electricianbalaji
Sikha te
You are great bro. Love from Bangladesh 💕
Kya haal hai bro
Thanku s aap aise hi video banaye
Very nice 👌
Kya haal hai Bhai
बहुत अच्छा से समझाते हैं सर
Nice bhai jaan💕💕💕
मै आपका चेला ho गया हु bhai
ITI students please follow the data sheet of MCB which direction MCB or RCCB should be connected. Now a days DB should be connected with proper RCCB and surge arrester. MCB have over current and short circuit protection and RCCB have leakage current protection. You should do wiring with proper ferrules, wire ties and connecting links. There should be double earthing in the DB. What I mean to say just like that you can't do wiring. You should follow the safety.
P
next practical now
👍️👍️👌👌
મેને બોલતી
Sir ji thanks Ab bath ya ha ki house wering ma invertor wering kasy karty ha jb light jaty ha tu light khud jalny chay
New Subscuriber💓💓💓👌👌🔔🔔
Very good Sir
Series lamp se test ko agar aap paper par draw karke samjhate to shayad jada samjh me aata sir .
Pahle MCB kam kese krta hye sir vo ap dekhlo....or tar upr se hi lagta hye q ki MCB ko dhayan rakte huwe ..
Or neutral tar..
K liye wala MCB box me canectr laga rahta hye sir...
Or tar niche lagane se MCB sahi tarike se kam nahi kr pata....thankuu sir itna batane k liye
V good
Bahut bahut dhanyawad Bhai
Good explanation ⚘️🙏
Good job 👏
Thank you so much very easy information
Thanks you sir😊❤
Bahut Acha bhai
Beautiful information.
Niche se pani nikla h ka bandro
Good work sir
MCB Par Line Or Load Likha Hota Hai Usko Dekhkar Hi Lagana Chahiye
Very very well good good line
Nice bhai
Thank you brother 💌
For looping 2.5 mm is insufficent you must use 4 mm or 6 mm otherawise must use strip
Very very nice video sir
But mera 1 problem hi
Sayad wo aap se bhi sahi nahi
Honewala hi
Kya haal hai Bhai
Bahi jan great great
Good jop sar nic vedo
Very good sir 👌👌🤝🤝👍👍
This is great video 👍👍👍👍
Great sir
Amir bhai aik ghar mey 2 mcb box ko kaisay lagatay hain , aor 1 meter se kaisy coonect kr saktay hain, is per aik achi video banaiey
Guru ji tank you
Thanks bhaiya
Very nice
Chek tha bord
Very nice sir😊
Jo me bolta hu vo me karta hu or Jo me nhi bolta vo definitely karta huu 😅😅
भैया मैंने आपकी वीडियो देख के सीखा है
Dhanawade Sir
Kya Maja Laga bhaia
Actually, You should add one RCCB.
Yes sir