Intro SHYSKY 24V 80W Speed Adjustable Micro Brushless DC Water Pump DC55E-24160A Threaded Ports

Поділитися
Вставка
  • Опубліковано 16 жов 2024
  • SHYSKY DC55E-24160A 24VDC Small Power efficient Brushless Water Pump 80W 16m 52ft Lift 634GPH Low noise, Speed/Flow Adjustable For Water Circulation Pressurization Cooling sys, IP68 Waterproof. For sample demand, www.amazon.com... . For bulk demand or for demand with customization, contact us directly, SHYSKYTECH@gmail.com .
    About this item
    [Speed Adjustable] SHYSKY DC55E-24160A Water pump,with external diameter of 20mm, outlet: G1/2, with external diameter of 20mm; Max static lift: 16 m (in pressure, 0.16MPa or 23PSI); Max horizontal flow rate: 2400 LPH (~ 40L/Min). Typical feature is with quite high lift (output pressure) value, but with relatively low flow rate, suitable for some micro pressure system; Speed/Flow Adjustable: User can adjust working power/ flow of pump at work through rotating potentiometer knob of pump, flexible at use.
    [BLDC design] Brushless DC motor, also known as EC motor; Magnetic Driven (NO DIRECT AC 100-240V POWER CONNECTION, PROHIBITED); Small size but strong; Low consumption & High Efficiency; Long time continuous working with low noise; Explosion - proof; Low noise about 40dB.
    [Wide applications] Low-voltage safety, high power-efficiency, low noise at normal work and supporting long-time continuous reliable running. This pump is widely applied for fountain landscape, medical equipment cooling circulation, air compressor cooling circulation, PC server water cooling, yacht/ vehicle water cooling, or other industrial, medical and household water processing systems. Pump cannot be self-priming, and it is important to make sure that there exists no dry run (especially for long time). Avoid impurities in the pumping systems.
    [Variety Power] 24V DC electric source, Battery, Solar Panel, etc; Soft Start with Low in-rush current, Especially suitable for Solar SYS who can not provide instant startup impulse current; Constant power level when powering vol. is over 24VDC yet under 28VDC, quite useful feature in some cases.
    [Dry Run Protection] DRY-RUN PROTECTION feature is integrated on the pump design now in default. Pump works at rated voltage: When there exists insufficient in-flow or no in-flow (or significant air bubble within), pump's DRY-RUN protection will be triggered: Pump will access stop-run-stop-run-stop-run--- cycle, greatly reducing rotation in this context. When in-flow comes sufficiently again, pump will then re-access normal run performance. This DRY-RUN protection is aimed to significantly reduce physical damage of pump from long time DRY RUN in some scenarios. Otherwise, pump could be conveniently dead due to long-time DRY RUN.
    NOTE: DC55E-24160A model, speed adjustable version, 24VDC, 3-phase brushless DC design, soft start. rated power 80W @ 24VDC. Max. Static lift appr. 16m @ 24VDC and Max. Horizontal flow rate appr. 2400LPH @ 24VDC.
    (CANNOT BE SELF-PRIMING; NO DRY WORK) Pay Attention: No dry work without water or with little water; otherwise, pump may be hurt. When users get pump, it’s recommended that a pre-test can be done in advance, then install to relevant application: get a bucket of water, locate the pump into water and power the pump with a matching DC power supply, check the work and performance of pump.
    As to control box of pump, strictly speaking, it’s not recommended to be located in the water; if indeed have to, waterproof tape is recommended to be firmly wrapped in advance. Of course, location out of water is more recommended.
    Important Notes about Pump’s use & installation
    DC 24V power supply. No direct AC power powering or over-voltage powering.
    If it is AC/DC Power adapter, make sure that it can offer sufficient power to pump: output capacity be 24VDC, 3.3A or over (24V*3.3A ~ 80W). Note that Power supply cannot be placed in water or moisty location.
    Pump supports continuous long time work with relatively low noise at normal working environment. Land use or submersible installation can be either OK, yet pump cannot be self-priming. Make sure that fluid can actively flow passing through inlet/outlet because pump works via centrifugal force of high-speed rotation of impeller inside (to push/throw in-flow out). No long-time dry work without in-flow, or it may damage the pump (Even though DRY-RUN Protection is equiped.).
    [Wide applications] Low-voltage safety, high power-efficiency, low noise at normal work and supporting long-time continuous reliable running. This pump is widely applied for fountain landscape, medical equipment cooling circulation, air compressor cooling circulation, PC server water cooling, yacht/ vehicle water cooling, or other industrial, medical and household water processing systems. Pump cannot be self-priming, and it is important to make sure that there exists no dry run (especially for long time). Avoid impurities in the pumping systems.