How do they do.. How to do Main air reservoir inspection onboard ship..

Поділитися
Вставка
  • Опубліковано 8 січ 2025

КОМЕНТАРІ • 8

  • @oualidmokhchy7042
    @oualidmokhchy7042 2 роки тому +1

    Hello Chief thank you for this video , I have a question about boiler . Lately i Got too many alarms of boiler , i opened the burner and i found too many cabon deposits around the diffuser and in combustion chamber . i wanted to adjust the distance between diffuser and flame tube but i didn't found the manual on board . So I decided to pull the diffuser a little bit back toward the nozzle so that i increase the secondary air , I need your suggestions pliz what do you think .

    • @marine-knowledge-basha
      @marine-knowledge-basha  2 роки тому +3

      thanks for your query,
      Please # check the air damper for correct operation .
      # check the fuel oil quality .
      # Check whether same condition occurs wen firing in diesel.
      # check the atomiser for any hole enlargement which can affect the atomisation.
      # check the diffuser plate for any choke.

  • @nilasithu5274
    @nilasithu5274 Рік тому

    Thank you sir

  • @bengalbay
    @bengalbay 2 роки тому

    Hello chief what medium should use to clean inside the air bottle?

  • @djjdjdhjdud2899
    @djjdjdhjdud2899 Рік тому

    Hi sir