How to install a 3-Phase Transformer | Maddox Industrial Transformer

Поділитися
Вставка
  • Опубліковано 9 лют 2025

КОМЕНТАРІ • 32

  • @polostyle7151
    @polostyle7151 Рік тому +3

    Awesome work

  • @bsdiceman
    @bsdiceman 3 роки тому +4

    Great video!

    • @MaddoxTransformer
      @MaddoxTransformer  Рік тому

      Thank you, Brandon, we really appreciate it!
      Please let us know if there are any other transformer-related topics you would like us to create content on.

    • @bsdiceman
      @bsdiceman Рік тому +1

      @@MaddoxTransformer oh i will keep that in mind. Thabks!

  • @aubreyroche5080
    @aubreyroche5080 3 роки тому +2

    Down and Dirty !!!!! Decent Job

    • @MaddoxTransformer
      @MaddoxTransformer  Рік тому

      Thank you, Aubrey, we really appreciate it!
      Please let us know if there are any other transformer-related topics you would like us to create content on.

  • @gustavotrevizo6957
    @gustavotrevizo6957 Рік тому +7

    After turning off the braker and lock out🔐 installation, they never check the power in the old transformer and put their hands over those bars, assuming everything is fine...

    • @MaddoxTransformer
      @MaddoxTransformer  Рік тому +2

      Hi Gustavo,
      This video is intended merely for informational purposes ONLY, not instructional. You should always have this kind of work done by licensed and experienced electrical contractor who is familiar with installing transformers.

  • @aubreyroche5080
    @aubreyroche5080 3 роки тому +5

    Maddox.... I will be looking into them..... I am An Electrician..

  • @510purple
    @510purple Рік тому +4

    you know why transformers hum? because they don't know the words.
    these xfmrs need annual maintenance, aka a shutdown, to vacuum dust build up and torque the lug connections.

    • @MaddoxTransformer
      @MaddoxTransformer  Рік тому +2

      Absolutely, regular maintenance is the best way to increase your transformer’s life. For liquid-filled units, we created this resource around Dissolved Gas Analysis (DGA) Tests and oil samples: www.maddoxtransformer.com/resources/articles/transformer-maintenance-dissolved-gas-analysis-and-how-to-pull-an-oil-sample/

  • @vponce7997
    @vponce7997 Рік тому

    Why is there two metal flexes going in on the high side

  • @generatorjohn4537
    @generatorjohn4537 3 роки тому +3

    I liked the lockout, tagout but expected to see a check for potential prior to making any kind of disconnection.
    Also expected to be shown the checking for phase rotation using a Knopps or similar device plus measured voltage output values, etc.

    • @MaddoxTransformer
      @MaddoxTransformer  3 роки тому +3

      This video is intended merely for informational purposes ONLY, not instructional. You should always have this kind of work done by licensed and experienced electrical contractor who is familiar with installing transformers.

  • @JermaineClarke-cw6oe
    @JermaineClarke-cw6oe 2 роки тому +6

    I noticed the transformer was not commissioned via any electrical testing.

    • @MaddoxTransformer
      @MaddoxTransformer  Рік тому +1

      Hi Jermaine,
      We always recommend using a licensed electrical professional when installing these units, who can perform electrical testing on the transformer.
      For more information about transformer testing please check out this guide: www.maddoxtransformer.com/resources/articles/guide-to-transformer-testing-standards/

    • @jsb7546
      @jsb7546 5 місяців тому +1

      When in doubt megger it out.

  • @avgluis
    @avgluis 3 місяці тому

    260.64(g) Grounding electrode conductors shall not be installed through a ventilation opening of an enclosure. NEC 2023

  • @michaeldavu250
    @michaeldavu250 Місяць тому

    Wear a suit when you energize that unit

  • @foreign-livingtheamericand8782
    @foreign-livingtheamericand8782 3 роки тому +1

    is the transformer connected directly to the incoming power with a shutoff then to a panel?

    • @riolop1972
      @riolop1972 3 роки тому +5

      Transformers like these are fed from the switchgears/switchboards which are fed from Edison/incoming power to vicinity

  • @Esspppiia
    @Esspppiia Рік тому +1

    That hole looks like crap and with the vibrations can nick the wire coming in from the bottom. FAIL.

  • @metalheadrelic9873
    @metalheadrelic9873 Рік тому

    Good thing those guys are wearing masks. Safety first. 🙄

  • @Alex-jo2oi
    @Alex-jo2oi 2 роки тому +3

    Now anyone can do it!
    Don’t really try this at home. You might hook it up incorrectly and then go boom boom

    • @MaddoxTransformer
      @MaddoxTransformer  2 роки тому +1

      Absolutely, make sure you use an experienced electrical professional to install your transformer.

  • @joewebb4836
    @joewebb4836 2 роки тому +2

    Loud buzzing noise (just a loose cover) , REPLACE IT !!!!

  • @dragonstuff1983
    @dragonstuff1983 3 роки тому +1

    Don't need Noalox, but ok.

    • @OrdinaryDude67
      @OrdinaryDude67 2 роки тому +1

      Could be job spec or manufacturer’s instructions.