😆☀️♥️💛✨Newton mein KitKat kata bhoot lagate Hain hamara gaon mein video bahut achcha Laga hamare liye bahut mehnat karta hai dil se chalo nice bhai 💖💝💖💔💛💔❤️♥️❤️♥️😆☀️💕☀️💕💕💝💥😆💝💝❤️💛💝💝💖💖💝💝🌹💔🌹♥️🌹🌹♥️🌹♥️🌹♥️💖♥️❤️💔❤️
@@kamleshelectrician sir ji aap neutral ka current check kar ke bata de please aur us per video banaye us se aap ka bahoot fayda bhi hoga jay jagannath
@@Goluji-tz3zj actually 4ac hain 1.5 ton ka 5 star jab amp check Kiya to 23-24 ho raha tha wo load 10mm ki wire se single phase me chal Raha hain,,,4kw to Mera contract load hain ussse me jyda hi usee karta hun
@@user-xk8zu1vg7w bhai 1ton ac ka power 3.5kw hota to 4 ac hai to 14 kw hota hai ham kewal 1ton ka ac ka lode bata raha hu abhi ac ke alawa lode hai to 4kw khaha se huwa Bhai aap apne ghar ke lode Galt bata rahe hai
neutral ka ampare check kerna tha ..aur neutral wire use hisab se size kerna zaroori he ...
well done bai.
ok
Main line service wire kitne mm ka dale hai aur kitne core ka hai
Me ek jagah me kam kr rha hu vaha 4ac aor lite sab fan v ha to single fhes me chalega kiya biya
Odisha se kaha se Ho bhaiya ❤
nuapada
@@kamleshelectrician mein Sambalpur se Hun bhaiyaa mein moter wanding ka kam karta hu.. mein apke savhi video dek ta hun 💓
Thank you so much for complete video
Most welcome
Thanks 🙏 bro
Welcome
😆☀️♥️💛✨Newton mein KitKat kata bhoot lagate Hain hamara gaon mein video bahut achcha Laga hamare liye bahut mehnat karta hai dil se chalo nice bhai 💖💝💖💔💛💔❤️♥️❤️♥️😆☀️💕☀️💕💕💝💥😆💝💝❤️💛💝💝💖💖💝💝🌹💔🌹♥️🌹🌹♥️🌹♥️🌹♥️💖♥️❤️💔❤️
thank you so much single phase Mein Laga sakte ho three face Mein Nahin lagana hai
Nice
Thanks
Mai 3 ac aur ek inverter chala rha hu but mcb db 40 amp hit ho rha aur heat hoke trip ho ja rha to kya kre , mere yaha voltage 170v aata hai
ab kya voltage kam hai to empier jyada Banega aapko empier jyada badhana padega
@@kamleshelectrician voltage badhane ka koi alag upay ho sakta hai agar neutral week hai main line me to Bina stabilizer ka
Use full sir 🙏
Thanks and welcome
😊😊😊😊😊😊😊😊
Super video
Thanks
Sir ji aap neutral wire per 9.5 amp aaya hai kya check kar ke bataye aap batayenge asi me aasha karta hoo aap ka kaam bahut accha hai
Per phase load 4899 waat hona chahiye
photo check nahin kar Paya bro pura
@@kamleshelectrician sir ji aap neutral ka current check kar ke bata de please aur us per video banaye us se aap ka bahoot fayda bhi hoga jay jagannath
Thanx you bhai
welcome
सारे वीडियो से ज्यादा ये वीडियो 1नं लगा 3phase distribution का नयूटल पर कटाऊट लगाना फालतु है यहा फेस की जरूरत है
kyon baki video achcha Nahin Laga kya aur hai three phase ka wiring ke bare mein video chal thank u so Mach
Kitchen m washing machine 😅
Netural ka wire kitne mm ka ahe
6 mm ka hai
Newton per kathor kyon nahin lagate Sadi bataiye
ok
Hlo sir
Total load is more then 16 kw 😮
1mm wire se Dfreezer chala sakte hai kya
chala sakte hain FIR duri pass rahana chahie
Single phase me 4kw Tak mere gharme aram se 10mm ki service cable se aram se chal Raha hain
Bhai 4kw ke li 10mm wir ki kya jarurat hai 6mm ke wir se pur ghar ke lode chalega
@@Goluji-tz3zj actually 4ac hain 1.5 ton ka 5 star jab amp check Kiya to 23-24 ho raha tha wo load 10mm ki wire se single phase me chal Raha hain,,,4kw to Mera contract load hain ussse me jyda hi usee karta hun
@@user-xk8zu1vg7w bhai 1ton ac ka power 3.5kw hota to 4 ac hai to 14 kw hota hai ham kewal 1ton ka ac ka lode bata raha hu abhi ac ke alawa lode hai to 4kw khaha se huwa Bhai aap apne ghar ke lode Galt bata rahe hai
@@Goluji-tz3zj3500 watt uski cooling capacity h na ki electric load. 1 ton ac ka load 1000-1200 watt hoga
@@Goluji-tz3zj actual load Kam hota hain vai,,1.5 ton ka ac running ke time max 6 amp leta hain, matlab 1400 watts ke aspas
Bhai aaisa nhi ho sakta ek phase fast floor pr oor dusra second floor pr
Nahin ho sakta hai distribute Nahin hoga kyunki first floor Mein Nahin rahenge aur ground floor Mein denge aur second floor Mein load bhi rahega to kaisa hoga
Bahut sare electrition krte h
Newton per kathor FIR kyon nahin lagta uska Karan kya hai
Newton ud jaega to 440 ho jaega
aneetal mein cut out nahin lagta
Brother use MCB TPN box
Not available
Iska kitna Paisa liye aap...??
₹6000 aur uska ghar ka aur kam tha to total Maine 20000 ka kam Kiya
हमें एक हैमर ड्रिल मशीन खरीदना है किस कम्पनी का खरीदे
बॉस कंपनी का
extra power kharido
Bhai UPS inverter ki wiring kai se kar te hai
ok
iska video Dala hua hamare UA-cam channel mein aap jakar dekh sakte hain
❤ 🙏🙏⛑️
kaisa Mukesh kam per nahin aana hai kya
@@kamleshelectrician आऊंगा सर
Main to Newtol link lagata hun Newtol mein
ham log bhi lagate Hain FIR nahin mila hamare