Precor Treadmill won't turn on

Поділитися
Вставка
  • Опубліковано 23 бер 2021
  • common problem with precor treadmills and burn wires

КОМЕНТАРІ • 15

  • @niuniusu2488
    @niuniusu2488 Рік тому +1

    Thanks ! You really helped us out.

  • @DrWenChannel
    @DrWenChannel 3 місяці тому +2

    Thanks so much! Can you please tell us the part# of that cable and where we can order one? Also, how do I remove that plastic cover to reveal that cable? What is IFT Box? Thanks again!

    • @coloradocardio
      @coloradocardio  3 місяці тому

      Parts can be purchased from gympart.com IFT box is the lower motherboard in the base of the treadmill this is what Procor called it and it says IFT on the box

  • @castaway123100
    @castaway123100 2 роки тому +1

    Where do you buy the replace wires?

  • @user-vp8jc1ws4f
    @user-vp8jc1ws4f 5 місяців тому +1

    my precorUSA C964i has error 21. Any idead?

    • @coloradocardio
      @coloradocardio  4 місяці тому

      Error 21, Too many Consecutive Power Requests- Error 21 observes a treadmill's power bit reading when the treadmill was operating at speeds above 1 mph. Power bits indicate the relative time that the motor controller drive circuit is turned on
      Silicone the running belt.

  • @ganeshthavare4924
    @ganeshthavare4924 2 роки тому +1

    Pls give me solution

    • @coloradocardio
      @coloradocardio  2 роки тому

      Troubleshooting steps 1 Verify motor connector is connected to drive 2 Check machine for stalling during operation 1MPH through 6MPH 3 Check error log for motor current during fault - If it is very low, check the connector and contacts, if it is over 7amps, it is likely a true stall condition 4 Check belt rating and current draw of treadmill - replace belt and deck if necessary.

    • @coloradocardio
      @coloradocardio  2 роки тому

      Apply treadmill silicone underneath the running belt

  • @ganeshthavare4924
    @ganeshthavare4924 2 роки тому +1

    My 954i tredmil showing error 20

    • @coloradocardio
      @coloradocardio  2 роки тому

      Motor Will Not Start / No Motor Movement Detected Applies to All AC drive motor treadmills Issue Symptoms The treadmill is monitoring the motor movement, through current monitoring. If the lower PCA does not detect that the motor is moving an error 20 will be displayed. This can be caused by a disconnected drive motor, or a very heavy user standing on the belt while starting. Troubleshooting steps 1 Verify motor connector is connected to drive 2 Check machine for stalling during operation 1MPH through 6MPH 3 Check error log for motor current during fault - If it is very low, check the connector and contacts, if it is over 7amps, it is likely a true stall condition 4 Check belt rating and current draw of treadmill - replace belt and deck if necessary.

    • @coloradocardio
      @coloradocardio  2 роки тому

      Apply treadmill silicone underneath the running belt

    • @skipdog77
      @skipdog77 7 місяців тому

      Precor belts are maintenance free. Do you still apply silicon to precor ?