PULSAR MINI 3200W BEAST | ONLY 47LBS | BEST PROPANE GAS DUAL FUEL INVERTER GENERATOR ? RV | CAMPING

Поділитися
Вставка
  • Опубліковано 27 лис 2024

КОМЕНТАРІ • 80

  • @MR_Garage
    @MR_Garage  Рік тому

    Jump straight to purchase this generator here:
    On Amazon
    amzn.to/4bylfkl
    On Ebay
    ebay.us/YESlDX
    Ebay Alt...
    ebay.us/wfCcTa
    🤔🤔🤔🤔🤔 Be sure to checkout my test video on this generator! New video contains upgrades, load test, sound test, oil change, valve last specs and more. ua-cam.com/video/NYrdNuRr2ec/v-deo.html 🤔🤔🤔🤔🤔

    • @trumpdanusan
      @trumpdanusan 9 місяців тому

      you right about plug or maybe it was not clicked on or something ran like shit. Ngk iridium started first pull fyi. Factory plug looked like real ngk nickle. Do not buy amazon faked

  • @TBoneSkrilla
    @TBoneSkrilla Рік тому +1

    Thanks for taking the time to produce this. Such a big help for the rest of us!

  • @jacksinthebox8029
    @jacksinthebox8029 Рік тому +4

    Relabled Genmax. For turning off the gas, if you move the dial to just before the off position(sweet spot is a hair out) it will close the fuel valve and run the carb dry. 1st time Ive seen that propane purge tip, nice.

    • @MR_Garage
      @MR_Garage  Рік тому +1

      Will give that a shot this weekend! Will also be load testing, decibel testing (for state parks), upgrading (spark plug, hour meter), providing valve clearance specs and probably more this weekend on this little gen. Good times.

    • @ZxAMobile
      @ZxAMobile 9 місяців тому +1

      @@MR_GarageBest review video of all time, amazing reviewer wtf!

    • @Inisfad
      @Inisfad 9 місяців тому

      Dinking also makes the Maxpeeding Rod generator. Basically the same thing except it comes with electric start. Sadly, the one I bought had a faulty battery, and it’s really difficult to use the recoil with propane. Looking forward to whatever trick you have about making the recoil start easier…..I will admit I haven’t gone to 18 yet, though, in trying to get the darn thing started.

  • @enthused7591
    @enthused7591 Місяць тому +2

    Yeah the Predator 3500 was nice when it came out, but now it's wildly overpriced and oversized/overweight compared to competition. It's so nice to see what's becoming available in the sub $550 range for inverter generators. The sweet spot to me is under 60 lbs, under 70 decibels, minimum 3600/3000 watts and preferably dual fuel, although I typically use ethanol free gas.

  • @brembofly
    @brembofly Місяць тому

    I’m really drawn to the Maxpeedingrod 4000GT for all its bells & whistles. Since you’re the go-to guy, I hope to see you take a look at it before I make a decision on one of these. Please don’t stop with the inserts, they are totally worthwhile!

    • @MR_Garage
      @MR_Garage  Місяць тому

      They had promised to send some units out for review and then never did which is unfortunate. I followed up a few times and it became pointless. They definitely have some bells and whistles to them!

  • @waltfriedrich7631
    @waltfriedrich7631 Рік тому +1

    The better StaBil fuel stabilizer is the blue marine. Since I started using it no more issues with weed whackers chainsaws etc.

    • @karlh5099
      @karlh5099 10 місяців тому

      Seafoam. Red stuff shit smells like pencils.

  • @donalddday7741
    @donalddday7741 Рік тому +1

    i have champion 2500 watt(3 years) and 2000 watt (2years) both run the 5000 btu window A C, battery charger, furnace off batteries and i have a plastic cover from a storage bin, with filters for air and 12 volt small radiator fan helps kept the dirt out and have had some surge on 2500 this last season in Arizona so i used small amount of acetone in gas tank (2 full tanks)and it stopped the surge i get 8 to 9 hours on one gallon of gas

    • @MR_Garage
      @MR_Garage  Рік тому

      Great generators! If taken care of, most current gens will last a really long time and serve you well.

  • @TheBudgetSportsman
    @TheBudgetSportsman 10 місяців тому +1

    Is there any possibility of changing out/upgrading the 30amp receptacle once you have it all torn a part? I saw your video of the new version that has the regular 30 amp RV plug, but I like the smaller size and weight of this unit better.

    • @MR_Garage
      @MR_Garage  10 місяців тому +1

      I had thought about the same thing but the low profile adapter it comes with works OK. I may revisit the idea soon. Just an annoyance.

    • @karlh5099
      @karlh5099 9 місяців тому

      Those adapters wiggle little may not be issue if units tight but never cut one open.

  • @tristanschaper281
    @tristanschaper281 11 місяців тому +1

    Great video! I just bought one on sale at Walmart $489. Still in the box and I'm planning to do the same mods and break in. Oh, I used your links to buy a few accessories like the magnetic dipstick, etc. Both of your videos are great! It looks like this is the same company that makes the Genmax, which seems to be taking the small inverter gen market by storm!

    • @MR_Garage
      @MR_Garage  11 місяців тому

      Right on and appreciated! Also yes, Genmax, Dinking and a ton of other white label products.

  • @caltari
    @caltari 25 днів тому

    Excellent review! I live in high altitude New Mexico, how do you get to the carburetor to replace the jet to a high altitude jet? Thanks in advance. Subscribed.

  • @MoroniGivens-jq9mi
    @MoroniGivens-jq9mi 7 місяців тому

    just checked valve lash cold .0025 Exhaust, Intake .002. That on good runner other one vibrates aleeady adj and did not take stock specs as .004 did not go in

  • @octwin
    @octwin Рік тому +1

    Would lining the plastic case where possible with dynamat (sound deadner) assist with lowering the DB’s or would you think it would retain to much heat and hurt the generator?

  • @imnguyen6658
    @imnguyen6658 4 місяці тому +1

    Thanks for the purge tip.

    • @MR_Garage
      @MR_Garage  4 місяці тому

      You bet! Makes life so easy starting on propane.

  • @inspectorzo
    @inspectorzo 10 місяців тому

    GREAT VIDEO!!! 1. Can you specify the dimensions of this unit? 2. I'm interested in installing it on a boat (dry space). Do you think it'll survive? 3. Would it be possible to setup a remote start on this unit? Thanks!

    • @MR_Garage
      @MR_Garage  9 місяців тому

      18.9"L x 11.4"W x 17.3"H per the specs. No possibility for remote start as it is a pull start only generator.

  • @busterhyman6633
    @busterhyman6633 11 місяців тому

    Thinking about buying a fourth one of these and trying to get 220 from two sets of two in parallel.

    • @tristanschaper281
      @tristanschaper281 11 місяців тому

      that wont work. You would have to buy the Genmax gens designed for 120/240.

  • @ChaJ67
    @ChaJ67 7 місяців тому +1

    As most of these newer small inverter generators are coming with a floating neutral and you tend to do tear downs anyway while at the same time most any use case for these small generators needs to have bonded neutral on the generator to be safe and comply with NEC codes, do you ever want to get into bonding the neutral in the generator as opposed to us realizing it is wrong and unsafe for our application just using a bonding plug?
    For an example of why it is unsafe is say you plug in a power tool with a metal case using an extension cord at the job site. The neutral has no tie to ground. So now say the tool develops a short to the case. Well now the metal case of the power tool and any exposed metal part of the generator is energized, so if you touch it, you are touching an energized surface. Now say you have neutral bonded to ground and you develop the same short to the case of the power tool. Now it has a path back to the source over the neutral-ground bond that you made and the breaker pops, clearing the fault. Now it is safe to touch the metal case of the power tool as well as touch any exposed metal parts to the generator.

    • @MR_Garage
      @MR_Garage  7 місяців тому +1

      A very good topic to discuss. I might cover it in a future video, dedicated to the topic. Such a quick and easy, I am surprised they don't just do this factory.

    • @acwilsn
      @acwilsn 6 місяців тому +1

      Excellent point and one that most buyers are unaware of. Some small generators such as the Honda EB2200i are bonded, while the EU2200i is not. I believe the reason manufactures may choose to not bond a particular generator is that it is mostly intended to power an RV, which already is bonded at the RV electrical panel. Only one bond is needed, as a second bond would create its own set of problems.

    • @Walt-c9m
      @Walt-c9m Місяць тому

      @@acwilsn I believe the only one neutral bond applies to house connections. The reason why they use the neutral bond plug is because when you hookup a un bonded generator to a rv surge protector it shows a fault and wont work. When you plug in the dummy neutral plug the surge protector works as normal.

    • @Walt-c9m
      @Walt-c9m Місяць тому

      If you don’t have an EMS in your RV, then you can use either a bonded or non-bonded neutral generator. If you DO have an EMS installed, then you’ll want to use a bonded neutral generator.

  • @karlh5099
    @karlh5099 9 місяців тому

    I Got mine start yesterday 20 pulls? Bled purged slowly so reg not trip. Once going vibrated a lot. Tried gas easy start. Should I try new plug. Hard restart when warm on choke over fueled wouldn't run. On run I do not think started when warm

  • @stevenmaniscalco1439
    @stevenmaniscalco1439 Місяць тому

    Thanks for the great info. I just ordered one for my aframe camper. What Spark plug replacement is best for this model? Also, is there a torque spec for valve cover after greasing gasket?Thanks.

    • @MR_Garage
      @MR_Garage  Місяць тому +1

      Aim for about 60 in-lbs or just snug. Not a lot of clamping force needed here. Also, all parts and such have links in the video description!

  • @MoroniGivens-jq9mi
    @MoroniGivens-jq9mi 8 місяців тому

    just adj valves .004 would not slide in either unit. Unit vibrared a lot now need put cover on run it

  • @ctm49
    @ctm49 9 місяців тому

    Great review, nice machine. I have the Dinking version and would like to add a quick connect for the propane side but the fittings seem too small for the quick connect kits I have looked at. Is there a way to do this? Thanks!

    • @MR_Garage
      @MR_Garage  9 місяців тому

      I have not checked into the quick connects as I rather have threaded fittings so I can bleed the line off before 1st start. I will try to determine the fitting size.

    • @ctm49
      @ctm49 9 місяців тому

      Thank you. I understand there are pros and cons to connection methods but I would like the option for quick connect if possible. Very much appreciate your help.

  • @NoZenith
    @NoZenith Рік тому +1

    Thank you

  • @RCronier78
    @RCronier78 2 місяці тому +1

    This is same phyical size as a Honda 2200. db level from videos isnt but around 2db difference which by ear almost is not noticeable. Im curious on if it will hold a 3200w load?

    • @MR_Garage
      @MR_Garage  2 місяці тому

      Yeah, I have a video on it load testing the generator. Outstanding little thing.

  • @stevenmaniscalco1439
    @stevenmaniscalco1439 Місяць тому

    Do you prefer this generator over the WEN 3600 dual fuel?

    • @MR_Garage
      @MR_Garage  Місяць тому

      I have not yet tested the Wen 3600. On paper, it looks decent enough, producing slightly less power than this pulsar. The digital display is a nice touch with hour meter already built in. Not knowing the OEM for it yet, I would stick with what I know and the GD400BN is a really good little gen. My personal generator these days that I kept is the Heimaito 4300iD. Such a nice unit for the cash. Runs amazing.

  • @KingTheDetailer
    @KingTheDetailer 3 місяці тому

    Hows the generator holding up , im a mobile guy looking for something smaller and powerful and compact to save space on my detailing rig. I will be using it everyday 4-6 hours a day. My predator 3500 just gave out , turns on but turns right off my be the carborator needs to be cleaned

    • @MR_Garage
      @MR_Garage  3 місяці тому

      Clean the carb and check valve clearances. Sounds more fuel related per your description. Never had an issue with these little GD400BN's! Less than half the weight of the predator. You are doing it professionally so my only thought is the lack of electric start. That is nice to have when you have to start every single day, sometimes multiple times.

  • @KRIL89
    @KRIL89 10 місяців тому

    Where did you get the adapter for the 30amp? I’ve got the regular gas version of this and mine didn’t come with one.

    • @MR_Garage
      @MR_Garage  10 місяців тому

      You can snag one here! amzn.to/3Hvctqt

  • @t.d.harris1311
    @t.d.harris1311 Рік тому +1

    Wow, never realized how many parts were in those little inverter generators. You need a job with NASA working on space ships with your mechanical ability. Best regards!

    • @MR_Garage
      @MR_Garage  Рік тому

      Thanks! This one was not bad to take apart. Only 3 different machine screw sizes.

  • @MR_Garage
    @MR_Garage  10 місяців тому

    My good people! Snag this generator for $509 + tax right now on Amazon! amzn.to/3UfPZBt🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔

  • @trumpdanusan
    @trumpdanusan 9 місяців тому

    motor have rubber isolators way attaches frame vibrations?

    • @MR_Garage
      @MR_Garage  9 місяців тому

      It does ! The only one I have seen lacking a few mounts is the little pulsar 1200w PGD16ISCO. Odd how they have half solid and half isolating mounts.

  • @giulianoargentin7656
    @giulianoargentin7656 Рік тому

    Put it on run mode and it will start right away.

    • @MR_Garage
      @MR_Garage  Рік тому +2

      They only start right away on propane if the line is bled and no oxygen in the line or carb. The trick with these on propane and many dual fuel generators: When first hooking up propane, bleed the line for about 6-8 seconds and then tighten. Starts in 1-3 pulls after that and 1 pull every time after it has run on propane. I do detail this in my videos.

  • @jeremyadkins7168
    @jeremyadkins7168 11 місяців тому

    What kind of run time are you getting on 25lb propane? Sounds like you know your stuff.. What would you recommend as far as longer run time on gasoline in case of emergency?

    • @MR_Garage
      @MR_Garage  11 місяців тому

      At 50% load, this gen uses around 1.61lbs if propane per hour. Standard tank holds around 17lbs of propane. If you truly have 25lb of propane in your tank, it should run for around 40 hours.

    • @racoonbreath
      @racoonbreath 8 місяців тому

      ​​@@MR_GarageI thought bbq tank holds 4.5 gallons? When I get empty take them propane guy always 4.5. Wonder what gallon oropane weight is.

    • @MR_Garage
      @MR_Garage  8 місяців тому

      Propane weighs 4.2lb per gallon. Most exchange places or people that fill, never fill a tank to the full 4.7 gallons they are rated for. You are lucky and have a good fill station! That is why I mentioned "holds around 17lbs". They can hold up to 19.74lbs but average more at 17 or even 15lbs.

  • @lonniesykes1818
    @lonniesykes1818 Рік тому

    How long is the warranty on this generator?

    • @lonniesykes1818
      @lonniesykes1818 Рік тому +1

      Just got a response from Pulsar and they told me one year parts and labor and two additional years for just parts.

    • @MR_Garage
      @MR_Garage  Рік тому

      1 year per Pulsar.

    • @lonniesykes1818
      @lonniesykes1818 Рік тому

      Interesting, they are telling me something different, you may want to email them to verify. But after seeing how you tore your generator down you are probably not too concerned about the warranty....lol!!! Thanks for the effort and time you put into these videos, it really helped me make my decision on purchasing this generator. The larger GX400BN was a nice unit, but the size of this one sealed the deal for me.@@MR_Garage

    • @MR_Garage
      @MR_Garage  Рік тому

      That's great! Their website shows 1 year. That is all the info I have to go off of. And nope - tearing down a generator (or anything) does not void warranty. Taking something apart does not void warranty. They would have to show or prove what was done caused the specific failure. Same with using aftermarket parts - not something that can legally void warranty but some (not pulsar) manufacturers try to make you believe it. Luckily, the GD400BN has been rock solid and I have zero reason to ask for warranty! The GX on the other hand...Still no call all week from Pulsar support. Had to followup with them to get a response which they asked for my number and then... crickets... nothing..... Amperage on display still does not work. Guess I have no choice but to send that one back. Bummer. I 100% agree, The size and weight of the GD is outstanding.

  • @trumpdanusan
    @trumpdanusan 9 місяців тому

    got email send video mine running seems rough shakes side side vibrates. Maybe do video with gas cap loose see wacks around

  • @rexkoons522
    @rexkoons522 Рік тому

    What decibel

    • @MR_Garage
      @MR_Garage  Рік тому

      My 2nd video goes through the sound level testing along with other testing.

  • @Westcareveterans
    @Westcareveterans 5 місяців тому

    This one doesn't come with a gas fuel automatic refill?

    • @MR_Garage
      @MR_Garage  5 місяців тому

      Not sure what this means?

  • @Notdb1gabe
    @Notdb1gabe 7 місяців тому

    What are the dimensions of it ?

    • @MR_Garage
      @MR_Garage  7 місяців тому

      18.9"L x 11.4"W x 17.3"H

    • @Notdb1gabe
      @Notdb1gabe 7 місяців тому

      @@MR_Garage thank you good sir

  • @MR_Garage
    @MR_Garage  9 місяців тому

    Nice! This gen is on sale on Amazon for $499! amzn.to/3IkwNeL

  • @MoroniGivens-jq9mi
    @MoroniGivens-jq9mi 8 місяців тому

    wait how adj valves? intake then exaust moved when came up tdc thought good. Now second guessing. Is this correct way? ua-cam.com/video/CMC-SUK4ogM/v-deo.htmlfeature=shared

    • @MR_Garage
      @MR_Garage  8 місяців тому

      You need to be on the compression stroke. Remove the spark plug and put your finger over the spark plug hole and turn over the engine with the rope. Air should push out the hole slightly on the compression stroke.

    • @MoroniGivens-jq9mi
      @MoroniGivens-jq9mi 8 місяців тому

      @@MR_Garage did you see Champion video? With decomp pull rope waited one valves be down then adj other. I waited valves go slack adj both sides same time? Thought that comp stroke. Cover off I can pull valve cover quick.