Hi DerHecht4.0, thank you for your work, it's very informative and useful. I have two questions 1. Which Web HMI would you recommend to work with WInCC unified? 2. Is it possible to setup unified with auto-login access i.e. user doesn't have to login on start up, it would just load a home page on HMI? TIA
Great video! Do you know if its possible to centrally manage colors and appearance etc. in Unified? (Classic had user-defined Styles). Maybe via Javascript? Idea for video? 👍😊
Hi, I don't know a way to manage it centrally. I found out that you have in the V17 a new Style with 2 schemes (bright/dark). But it is not possible to manage your own Style.
Hi, thanks a lot for the tutorial. I have a question, can we have both this web application and the so called "User Defined Pages" . Currently I just wanted to test this VOT but I keep getting error 404 when asking for the ViewOfThing Link. Thanks in advance.
Hi, I have check it. It is possible to run the "User Defined Pages" and VoT at the same time. You get two entries on the website from the controller. I donät know why you get this 404 error.
Hallo DerHecht4.0, I have one general question to TIA Portal. What PC are you using or what TIA/Windows Settings that TIA Portal is running so fast?? I've already asked SIEMENS (Fachberatung) directly, but still waiting for answer from Siemens Developers. Maybe you can do Tutorial, how to set up TIA/Windows properly? Thank you for very interesting channel!! Great Job!
Hi Jemiol it is not always so fast. I cut the compile/download dialogs a bit. Because I don't want you to waste your time looking at these dialogs in the videos. I think you have enough of it, if you work with TIA every day. I use a HP ZBook G3: - i7-6820HQ @ 2,7 GHZ, - 48GB Memory - 1TB SSD Samsung 850 PRO For my TIA VMs, I Use 16 GB of Memory and for the Processors settings: Number of processors: 2 Number of cores per processor 2
Hallo @@DerHecht40 , I'm using Lenovo P71 - Intel(R) Xeon(R) CPU E3-1505M v6 @ 3.00GHz 3.00 GHz -64,0 GB RAM -1TB SSD Samsung 980 PRO For my TIA VMs, I Use 32 GB of Memory and for the Processors settings: Number of processors: 2 Number of cores per processor 2 But I've tried also to work Directly on our Server with VM's so i could put more Power 64GB RAM ... no big change. Friendly Siemens Dev told me that TIA can't use more than 16GB RAM anyway. My Coworkers have comparable Laptops only with i7 10th gen, the same situation. When we're watching yours tutorials or official Siemens webinars there is everything almost half faster. I know that Siemens guys like you :) receiving Prepared VM from Development Departament, with everything Installed already. I'm on the good way to get one also to compare the settings ad we'll see. If i'll find something, i'll write this here in comments, if you have nothing against it. MfG Jemiol
Hi Jemiol, I don't get a ready configured VM from Siemens development, this would be nice. SO I would save a lot of time with this instalaltion stuff. I have prepared this windows image with the TIA/Unified installion. I disable a lot of windows stuff in my basic VM like Update services, cortana, games, ...... If you find something I would be grateful to share it here
Hi DerHecht4.0, I tried yesterday VoT on the real PLC and I found one problem. I created one VoT and uploaded it to PLC and it was working fine, but then I changed this VoT a little bit and uploaded it agan but the web server was still showing the old VoT. I tried everything, PLC to STOP and back to START, compiling everything, but this problem was always there. I had to change the name of the VoT application and upload it again and then it was working. Did you had the same problem?
Hi Simon, I am not aware of anything. All VoT changes were taken direct. It is important that you each time do a manual VoT compile before you donwload it. A Normal PLC Compile does not compile the VoT application
That's weird. I have checked it again 1. I do a change in the screen e.g., add a new object to my screen 2. compile the VoT Application 3. press download of the PLC 4. set "update online" in the download dialog 5. to a screen change in the VoT Screen 6. my new object is displayed
Total waste of time. Vot doesnt support more than 100 tags. S7 1500 is only used for big projects and yet this stupid idea doesnt allow more than 100 tags to be implemented in several pages. If i had only 100 tags i would have had bought a delta plc with lower price
Thank you very much, that was intresting!
Hi DerHecht4.0, thank you for your work, it's very informative and useful. I have two questions 1. Which Web HMI would you recommend to work with WInCC unified? 2. Is it possible to setup unified with auto-login access i.e. user doesn't have to login on start up, it would just load a home page on HMI? TIA
Great video! Do you know if its possible to centrally manage colors and appearance etc. in Unified? (Classic had user-defined Styles). Maybe via Javascript? Idea for video? 👍😊
Hi, I don't know a way to manage it centrally. I found out that you have in the V17 a new Style with 2 schemes (bright/dark). But it is not possible to manage your own Style.
Bei mir kommt, nachdem ich im Webbrauser das Projekt starte, die Meldung "Runtime not active". Wie kann ich "Runtime" aktivieren?
Hi, hast du auch den haken beim download gesetzt 05:23
@@DerHecht40 Jetzt klapps - danke für die Unterstützung!
Hi, thanks a lot for the tutorial. I have a question, can we have both this web application and the so called "User Defined Pages" . Currently I just wanted to test this VOT but I keep getting error 404 when asking for the ViewOfThing Link. Thanks in advance.
Hi, I have check it. It is possible to run the "User Defined Pages" and VoT at the same time. You get two entries on the website from the controller. I donät know why you get this 404 error.
Hallo DerHecht4.0,
I have one general question to TIA Portal.
What PC are you using or what TIA/Windows Settings that TIA Portal is running so fast??
I've already asked SIEMENS (Fachberatung) directly, but still waiting for answer from Siemens Developers.
Maybe you can do Tutorial, how to set up TIA/Windows properly?
Thank you for very interesting channel!! Great Job!
Hi Jemiol
it is not always so fast. I cut the compile/download dialogs a bit. Because I don't want you to waste your time looking at these dialogs in the videos. I think you have enough of it, if you work with TIA every day.
I use a HP ZBook G3:
- i7-6820HQ @ 2,7 GHZ,
- 48GB Memory
- 1TB SSD Samsung 850 PRO
For my TIA VMs, I Use 16 GB of Memory and for the Processors settings:
Number of processors: 2
Number of cores per processor 2
Hallo @@DerHecht40 ,
I'm using Lenovo P71
- Intel(R) Xeon(R) CPU E3-1505M v6 @ 3.00GHz 3.00 GHz
-64,0 GB RAM
-1TB SSD Samsung 980 PRO
For my TIA VMs, I Use 32 GB of Memory and for the Processors settings:
Number of processors: 2
Number of cores per processor 2
But I've tried also to work Directly on our Server with VM's so i could put more Power 64GB RAM ... no big change.
Friendly Siemens Dev told me that TIA can't use more than 16GB RAM anyway.
My Coworkers have comparable Laptops only with i7 10th gen, the same situation.
When we're watching yours tutorials or official Siemens webinars there is everything almost half faster.
I know that Siemens guys like you :) receiving Prepared VM from Development Departament, with everything Installed already.
I'm on the good way to get one also to compare the settings ad we'll see.
If i'll find something, i'll write this here in comments, if you have nothing against it.
MfG Jemiol
Hi Jemiol,
I don't get a ready configured VM from Siemens development, this would be nice. SO I would save a lot of time with this instalaltion stuff. I have prepared this windows image with the TIA/Unified installion. I disable a lot of windows stuff in my basic VM like Update services, cortana, games, ......
If you find something I would be grateful to share it here
Hi DerHecht4.0,
I tried yesterday VoT on the real PLC and I found one problem.
I created one VoT and uploaded it to PLC and it was working fine, but then I changed this VoT a little bit and uploaded it agan but the web server was still showing the old VoT.
I tried everything, PLC to STOP and back to START, compiling everything, but this problem was always there.
I had to change the name of the VoT application and upload it again and then it was working.
Did you had the same problem?
Hi Simon,
I am not aware of anything. All VoT changes were taken direct. It is important that you each time do a manual VoT compile before you donwload it. A Normal PLC Compile does not compile the VoT application
Maybe do you need refresh the web page on computer, with shift F5?
Good objection . Or perform a screen change. By pressing F5 you need to login again
@@DerHecht40 I tried all of that, but still my VoT application was stuck.
That's weird. I have checked it again
1. I do a change in the screen e.g., add a new object to my screen
2. compile the VoT Application
3. press download of the PLC
4. set "update online" in the download dialog
5. to a screen change in the VoT Screen
6. my new object is displayed
Total waste of time. Vot doesnt support more than 100 tags. S7 1500 is only used for big projects and yet this stupid idea doesnt allow more than 100 tags to be implemented in several pages. If i had only 100 tags i would have had bought a delta plc with lower price