Installing a Single Phase Hybrid Inverter Deye x V-TAC

Поділитися
Вставка
  • Опубліковано 15 тра 2023
  • Discover how to quickly install and set up your V-TAC x Deye inverter for instant solar power!
    Our step-by-step tutorial is the ultimate guide for professional installers and DIY enthusiasts to embracing renewable energy.
    3.6kW - SKU 11725 - SUN-3.6K-SG03LP1-EU
    5kW - SKU 11547 - SUN-5K-SG03LP1-EU
    6kW - SKU 11537 - SUN-6K-SG05LP1-EU
    8kW - SKU 11803 - SUN-8K-SG01LP1-EU
    v-tac.eu/
    #DeyeInverter #InverterInstallation #RenewableEnergy #SolarPower #SolarEnergy #CleanEnergy #SustainableLiving #GreenEnergy #DIYInstallation #HomeRenewableEnergy #EnergyIndependence #SolarSystem #InverterSetUp #EfficientEnergy #InverterTechnology #vtacsolar #vtacenergy #vtacinverters
  • Наука та технологія

КОМЕНТАРІ • 12

  • @RashaadAli
    @RashaadAli 10 місяців тому +1

    Excellent

  • @pedrobrenes3061
    @pedrobrenes3061 6 місяців тому

    Hola, me gustaría saber que app tiene el inversor para conectarlo al móvil y como quitar la tapa para.conectar la antena wifo, gracias

  • @gabriel-neamtzu
    @gabriel-neamtzu 3 місяці тому

    Salutare! Back-up boxul la invertoarele deye monifazate (3-6kw) este integrat sau se achiziționează separat? Mă interesează dacă funcționează fara rețea doar de la panouri fara baterie cum sunt invertoarele sungrow si sofar....

  • @andreaspinelli8506
    @andreaspinelli8506 5 місяців тому

    Hello. How can resolve my problem? When svich off grid ,i have 115 Volt between F and PE and 115 between N AND PE.

  • @ChristopherChaula-nk2ch
    @ChristopherChaula-nk2ch 3 місяці тому

    This inverter with battery very good

  • @user-ug9mj7iz5y
    @user-ug9mj7iz5y 17 днів тому

    what is different between sg05 and sg03 or sg04?

  • @nebuneli
    @nebuneli 8 місяців тому +1

    when connected to grid but you have pv and batterie connected what will happen if there is a power outage ? will the inverter go through 0 for a few seconds ?

    • @Goreuncle
      @Goreuncle 8 місяців тому +1

      Anything connected to the LOAD port will keep working as if nothing happened (as long as you have enough solar production / battery charge to take on the demand), this inverter will immediately isolate itself from the grid and perform the transfer to ups mode in ms, it's quite impressive.
      However, keep in mind that the LOAD port is only meant to power type II electronic devices when working off-grid (ups mode).
      This is because it switches to a floating neutral configuration, which has no earth reference.
      In this configuration, RCDs won't trip and some devices won't work.
      If you want it to power type I electronic devices safely and want your RCDs to work when in ups mode, you need to add an external contactor connected to the inverter's ATS port, to perform a neutral-earth bond (only when off-grid).
      Sunsynk made a couple of videos about it, check them out.

  • @user-bj9bx9to6s
    @user-bj9bx9to6s 11 місяців тому

    why battery data cable Bat_Com and Inv_Com .. are this not allowed to be reverse ? or this cable same with networking cable ?

    • @V-tacEu
      @V-tacEu  10 місяців тому +1

      No, it needs to be plugged exactly in this way. It may look as a standard network cable but the ends are specific to the ports of the inverter and battery.

  • @ati4094
    @ati4094 Рік тому

    Браво ,без да продаващ ток само за лично ползване ,настройките можели видео ,имам от същия deye 5kw ,скоро ще си вземам v-tag батерия

    • @V-tacEu
      @V-tacEu  11 місяців тому

      Здравейте! Във видеото са показани настройките нужни за стартиране на инвертора с използване на енергията без продаване.