    In this video series I attempt repair of an Agilent E3631A Linear PSU.
    Here is part 2:-
    • No.069 - Agilent E3631...
    3D printed nut spinners - www.ianjohnston.com/images/st...
    Visit my website for lots more - www.ianjohnston.com
    Help me make more of these videos:
    Pledge using Patreon - / iansjohnston
    Donate using PayPal - www.paypal.me/IanSJohnston
  • Наука та технологія

КОМЕНТАРІ • 42

  • @davidv1289
    @davidv1289 3 роки тому +4

    Wow, that certainly meets the definition of a "face plant". I really expected it to work after the front panel replacement. It must have failed first and then was damaged in storage/shipment. This should be another excellent series of power supply repair videos! Thank you, David.

    • @IanScottJohnston
      @IanScottJohnston  3 роки тому +1

      The PSU was packed really well. The unit reflected the photos of the unit prior to shipping. There is a sticker on the enclosure "powers on, cannot control output".....LOL!

  • @amirb715
    @amirb715 3 роки тому +7

    Great video as always. I highly recommend you check the opto couplers on the main regulator board as well. Mine had two of them dead plus the opamp that you just replaced (OPA27) and also one or two of the resistors around the ADC were also open. So it seems those components are dodgy in this series

  • @davidandrews8566
    @davidandrews8566 3 роки тому +7

    I was surprised the display survived the front panel damage.

  • @tommyh4049
    @tommyh4049 3 роки тому +4

    This is definately more involved that a loose wire or blown fuse.

  • @akhurash
    @akhurash 3 роки тому +1

    Good job troubleshooting.

  • @alpcns
    @alpcns 3 роки тому

    Hummm.... A box of mysteries! Interesting. Merry Christmas, Ian!

  • @GadgetUK164
    @GadgetUK164 3 роки тому +1

    Fantastic part 1 =D

  • @benmodel5745
    @benmodel5745 3 роки тому +1

    This one seems like a fun one, GL!

  • @tonybell1597
    @tonybell1597 3 роки тому

    Excellent vid Ian. Thanks... Happy Christmas to you ......

  • @TheDefpom
    @TheDefpom 3 роки тому +2

    Yay another repair :-)

  • @TheDefpom
    @TheDefpom 3 роки тому +1

    On The 3647 there was also a supervisor IC which messed with the 5V rail causing it to not sense the voltage, not sure if that is the same architecture.

  • @koffibanan3099
    @koffibanan3099 3 роки тому

    Great, you really seem to get the interesting ones lately!

  • @TheDefpom
    @TheDefpom 3 роки тому +1

    The HCNR200 opto couplers are a suspect from me, I had issues with those on a 3647A

    • @IanScottJohnston
      @IanScottJohnston  3 роки тому +2

      The analogue signals are reaching the multiplexer IC just fine. The ADC isn't working, the integrator is doing nothing.
      Funnily enough, my own home made PSU from years back used the same analogue opto-couplers I think (terrible things, their tempco is BAD), so I have loads of them.

  • @SeanBZA
    @SeanBZA 3 роки тому +1

    Been buying from Puerto Rico then, I hear they have some equipment "removed from a working installation" for sale, only one owner, might have been dropped once.

  • @Yorumcu63
    @Yorumcu63 3 роки тому +1

    Great Video.I have a question about green matt on desk .it is very clear .What is using or cleaning .mine is very dirty and alchol and cleanng materials not enought for cleaning

  • @ahmedalshalchi
    @ahmedalshalchi 3 роки тому +1

    Ian Scott Johnston ... I envy you for your FLUKEs ...

  • @priestblood
    @priestblood 3 роки тому

    Hi Ian,I amlong time fan ,would you share your duel psu schematics and code from the upgrade you did to convert to two big lcd displays I would love to update mine as the display is very weak and on it's way out ,I was hoping to put lcd displays and a digital voltage and current keypad on but not sure where to start would love a peek at the code you wrote buy any help would be appreciated, thank you for the great content, best wishes

  • @twobob
    @twobob 2 роки тому

    open relay circuit? initial reaction. does it have such a module? Now i'm sucked in... lol

  • @douro20
    @douro20 3 роки тому

    I guess you're still evaluating the Envox BB3?

  • @shanlee5950
    @shanlee5950 3 роки тому

    I need a cover case. Please tell me where to buy it?

  • @janedoe6182
    @janedoe6182 Рік тому

    Big caps in parrallel of outputs? Is it normal for lab PSU? What about fast current limiting?

  • @kimalexanderhansen5318
    @kimalexanderhansen5318 3 роки тому

    I have one of those in "to be fixed" condition. Binding posts are shot..

  • @gbowne1
    @gbowne1 3 роки тому

    Whomever "dropped that one from a great height" should be "dropped from a great height" for damaging that PSU. Looks like you got on with it though :)

  • @you2ber252
    @you2ber252 3 роки тому

    07:21 check that you have actually soldered the rightmost capacitor to the roghtmost banana post ;-)

  • @jean-claude836
    @jean-claude836 3 роки тому +1

    Nice repair! Thank for sharing. Is it possible you add subtitles option to be activated for next videos. It will be helpfull for me!!!

    • @IanScottJohnston
      @IanScottJohnston  3 роки тому +1

      Well, I can experiment with them and see how they behave with the Scottish accent.....:)

    • @jean-claude836
      @jean-claude836 3 роки тому +1

      @@IanScottJohnston Thank

    • @IanScottJohnston
      @IanScottJohnston  3 роки тому +1

      @@jean-claude836 I've added for the previous four videos, but it won't let me add for this video......I will try again in a few days.

  • @Mr.Leeroy
    @Mr.Leeroy 3 роки тому

    7:30 should these caps even be there?

  • @ahmedalshalchi
    @ahmedalshalchi 3 роки тому

    My friend , never ever go into CAL mode unless all circuitry is functional 100% and you need for CALibration to get accuracy , otherwise , keep away from any CAL modes on any TMI ... Also , from my long experience , I rarely got faulty OP-AMPs so please recheck those faulty parts you have thrown away , might be working !!...

    • @IanScottJohnston
      @IanScottJohnston  3 роки тому +2

      I respectfully disagree, page 66 of the service manual states that you can terminate any cal setup without changing its calibration constants by turning off power.....which is what I did. My observation in there was to attempt to see if there was any corruption and no more.
      Since 1984 when I first got attached to the EE workbench I have had plenty of faulty op-amps.....:-)

  • @TheDefpom
    @TheDefpom 3 роки тому +1

    Did you get it from Israel ? stuff from there is always smashed or corroded.

    • @IanScottJohnston
      @IanScottJohnston  3 роки тому +1

      This one did, as did my Stanford Research SR650.....I like the smashed up stuff.

    • @largepimping
      @largepimping 3 роки тому +1

      Heh... I was starting to type exactly the same question. I guess it's "that one seller" that everybody seems to know about...