கம்ப்ரஸ்ஸர் ஸ்டார்டர் To பிரஸ்ஸர் லிமிட் சுவிட்ச் கனெக்க்ஷன் Electrical Express | TAMIL

Поділитися
Вставка
  • Опубліковано 27 вер 2024
  • Please visit our website for more information
    vkjsolutions.com/ how to connect pressure limit switch to compressor motor starter
    pressure switch
    air compressor
    compressor pressure switch connection
    air compressor pressure switch,compressor
    how to set air compressor pressure switch
    compressor starter connection
    #air compressor pressure switch wiring
    #how to wire a 3 phase air compressor pressure switch
    how to adjust pressure compressor
    air compressor starter pressure switch motar connection
    compressor starter connection with pressure switch
    Shopping online BUY using the links below & Support Us
    amzn.to/3hau4qt
    follow in my instagram id:
    / electricalexpresstamil
    Join my face book group
    click link. / 558083051460112
    LIKE | COMMENT | SHARE |
    SUBSCRIBE
    **************************************************************
    CONTACT DETAIL
    **************************************************************
    Email : vijayakumarariyur@gmail.com
    **************************************************************
    Hello friends, Welcome to "Electrical Express Tamil" My Channel motivation is Easy to Understand, Electrical Tech Videos in Tamil, and Get Latest Tech Updates in Tamil , We do Tips and and also Innovation, I wanted each and every Individual whoever is interested in electrical technology to be able to understand it in the easiest possible way,
    Thanks.
    -Vijayakumar.K
    **************************************************************
    உங்களுக்கு எது போன்ற வீடியோகள் வேண்டும் என்பதை கமெண்ட் - ல் குறிப்பிடவும்.
    மேலும் பல விடியோவுக்கு சப்ஸகிரைப் செய்யுங்கள் நன்றி ..
    **************************************************************
    DISCLAIMER: This Channel DOES NOT Promote or encourage Any illegal activities , all contents provided by This Channel.
    Copyright Disclaimer Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favor of fair use.
    **************************************************************
    / electricalexpresstamil

КОМЕНТАРІ • 57

  • @AIRPNEUMATICS007
    @AIRPNEUMATICS007 8 місяців тому

    12v use panna mudiyum ahh sir etha cut starter

  • @ArthisanN
    @ArthisanN 3 роки тому

    Super Definition Brother 👍

  • @giribodipatti4241
    @giribodipatti4241 3 роки тому

    Super put video on RYB and UVW difference

  • @kumars7542
    @kumars7542 5 місяців тому

    Sir eppadi prasser set seivathu eppadi sollunga

  • @rameshnarayanan8281
    @rameshnarayanan8281 3 роки тому +1

    Thank you sir

  • @pradeeprk983
    @pradeeprk983 3 роки тому +1

    bro itha eppadi automatic ka ON OFF panrathu, owvaru time mu namma poi ON panna mudium ma, i think avaru kudutha connection than correct .

    • @yogaashwin5241
      @yogaashwin5241 3 роки тому

      Need another one contactor.. Andha contactor ku start stop switch potu andha contactor oda oru NO terminal ah indha starter oda holding contact ah tharanum.. Bt konjam complicated ah irukum..

    • @electricalknowledge1752
      @electricalknowledge1752 2 роки тому +1

      @rajkumar yes old diagram correct but no need holding contact, only pressure switch should be connect parrallel to start button

    • @pvn2936
      @pvn2936 2 роки тому

      Scenario : pressure goes below set point
      scheme #1:
      Motor turns on automatically
      Scheme #2:
      Plant suffers from insufficient compressed air. so, you push Momentary N.O., whenever this scenario arises.

  • @ThennarasuR
    @ThennarasuR 3 роки тому

    Bro, pls research on automating both ON and OFF function. Refer automatic water level controller - with starter circuit.

  • @rahmankhan-ev6hj
    @rahmankhan-ev6hj 4 місяці тому

    Hello sir en meto air compressor hp.1.0 rpm 700 ok but enna problem 70,air full motor black ahkuth enna problem

  • @megasri3a934
    @megasri3a934 Рік тому

    அருமை

  • @seenivasnseenivasan2878
    @seenivasnseenivasan2878 3 роки тому

    Super anna

  • @saracorporation5168
    @saracorporation5168 3 роки тому +2

    சார்... ஒரு டவுட் சீலிங் பேன் போட்டா led டிவி ஆப் ஆகி ஆன் ஆகுது ப்ரோப்லம் என்னவா இருக்கும்...

  • @sivajagansivajagan6634
    @sivajagansivajagan6634 2 роки тому

    New compress stuck stuck pothu enna panarathu please tell me sir

  • @giribodipatti4241
    @giribodipatti4241 3 роки тому +1

    In my house having 2 service in one service earth symbol is flickering and in another service earth symbol is showing without flickering what is this reason

    • @ElectricalExpressTamil
      @ElectricalExpressTamil  3 роки тому +1

      Contact number please

    • @ElectricalExpressTamil
      @ElectricalExpressTamil  3 роки тому

      Mail me electricalexpresstamilvk@gmail.com

    • @ThennarasuR
      @ThennarasuR 3 роки тому

      I think (asssume) ur using two services in ur home with 3 phase rotatory switches, (neutral is common)
      Using this switch ur connecting few loads to one service and few loads to another service.
      In this method, neutral of both service's meters joined OR neutral from only one meter is used. Because of that phase current and neutral return current become different. This is the reason for that symbols it may lead to over costing.
      To avoid this use change over switches instead of rotatory switches OR connect all the loads to one service for one month and second service for another month using rotatory switches. In that time switch off mains of un used service.

    • @giribodipatti4241
      @giribodipatti4241 3 роки тому

      @@ThennarasuR I'm using single phase having rotary switches not yet applied for 3phase

    • @ThennarasuR
      @ThennarasuR 3 роки тому

      @@giribodipatti4241 bro 3 phase supply ya sollala, 3 phase ku use panra 3 rotary switch ah sonnen

  • @nirmaticstrichy216
    @nirmaticstrichy216 2 роки тому

    Sir
    Single pahase starter connection
    Sollunga.pl

  • @nrweavers3321
    @nrweavers3321 2 роки тому

    அண்ணா வணக்கம்.
    எங்கள் வீட்டில் ஏர் கம்ப்ரசர் 9 வருடம் யூஸ் பன்னீட்டு இருக்கோம் ஆனால் இப்போது ப்ரிசன் ஸ்விட்ச் கீழேயுள்ள வாழ்வில் ஏர் கட்டாயப் ஆகும் பொழுது ஏர் போய்க்கொண்டே உள்ளது. இதற்கு தீர்வு கூறவும் அண்ணா

  • @poovizhikannanm5230
    @poovizhikannanm5230 3 роки тому

    Neenga tneb retired staff ah?

  • @yogaashwin5241
    @yogaashwin5241 2 роки тому

    Oru oru tym um namma start panna dha start agum nenga correct panna diagram la...

  • @kingsarun8575
    @kingsarun8575 3 роки тому

    Submersible starter start pannautan elcb trip akuthu ena problem bro slunga

    • @ElectricalExpressTamil
      @ElectricalExpressTamil  3 роки тому

      Submersible pump பொருத்தவரை லீக்கேஜ் கரண்ட் அதிகம் எனவே டிரிப் ஆகத்தான் செய்யும் எனவே
      கண்ட்ரோல் பேனல் ஃபோர்டு மட்டும் எர்த்திங் செய்யுங்கள்

  • @saravanaamp982
    @saravanaamp982 3 роки тому

    Hello sir oru help

    • @ElectricalExpressTamil
      @ElectricalExpressTamil  3 роки тому

      ?

    • @saravanaamp982
      @saravanaamp982 3 роки тому

      @@ElectricalExpressTamil eb meter layee neutral n phase layum supply varuthu enna pannalamnu sollunga sir entha load ume use panla

  • @ARMANI-gr2fb
    @ARMANI-gr2fb 2 роки тому

    இது pressure switch

  • @dhakshanamoorthiparthasara6349

    Contact no sir

  • @abdulahamed876
    @abdulahamed876 9 днів тому

    நான் சொல்றோன் தப்ப நினைக்காத முதல்ல பொய் பேச வேண்டாம் மல்டி மீட்டர் வைத்து போட்ட விடியோவ நான் சொல்கிறோன்

  • @r.senthilkarthikeyanr.sent6641
    @r.senthilkarthikeyanr.sent6641 Місяць тому

    Every time we want to go and on the compressor after pressure get high?

  • @selvamdiya2229
    @selvamdiya2229 2 роки тому +1

    Super explain sir

  • @LokeshLokesh-sm7rp
    @LokeshLokesh-sm7rp 10 місяців тому

    Star delta stater usage

  • @murugesans4019
    @murugesans4019 2 роки тому

    நீங்கள் எலக்ட்ரிக்கல் காண்டக்ட் பெற

    • @sathyakumarr6738
      @sathyakumarr6738 2 роки тому

      🙏 என்ன செய்ய வேண்டும் என்று சொல்லுங்க நண்பா?

  • @manikkamvasagam1710
    @manikkamvasagam1710 2 роки тому

    Sir. 3 phase illana. 2phase run panna mudiuma

  • @tkannan7185
    @tkannan7185 3 роки тому

    சூப்பர் நண்பரே ராசிபுரம் கண்ணன்

  • @eswaramoorthya2943
    @eswaramoorthya2943 3 роки тому

    Superb

  • @paulmuthu6370
    @paulmuthu6370 3 роки тому

    நன்றி 🙏

  • @govindanchelliah8450
    @govindanchelliah8450 3 роки тому

    Draw clear
    technical drawing, please

  • @ganeshgabriel41
    @ganeshgabriel41 2 роки тому

    Sir... 3 phase compressor running la oru phase cut ayuruthu sir enna prbm ma irukum

  • @govindanchelliah8450
    @govindanchelliah8450 3 роки тому

    Draw circuit diagram best method