Citroen Peugeot Adblue pump and module - stripdown

Поділитися
Вставка
  • Опубліковано 22 сер 2024
  • Some components and general overview. Not an educational video. It had a P20E2 Pressure of the urea fluid : Urea Pressure Too Low fault. I cannot find any more info on circuitry of the module. Usually (if pump not leaking onto module) it works again after bench testing the pump and solenoid. Strange thing...

КОМЕНТАРІ • 34

  • @MikeBetynaVANS
    @MikeBetynaVANS  Рік тому +1

    Notice the temp sensor inside the unstripable tank at 7:48 looks the same as the ambient temp sensor in the mirror :D

    • @marks6809
      @marks6809 2 місяці тому

      do you know proper resistance for device measuring adblue level in tank ? thanks

    • @MikeBetynaVANS
      @MikeBetynaVANS  2 місяці тому

      @@marks6809 It is a Hall effect type float sensor. So it should have 3 wires to it: 5v , ground, signal(0.4v-4.5v). It is not recommended to resistance check this type of sensor. If you are dealing with level problems on the same tank, try hitting it with rubber mallet from undeneath (after you drain the adblue) and refill. Worked for me.

  • @APACHE-nf1ww
    @APACHE-nf1ww Рік тому +4

    Благодарю за видео, было бы здорово добавить ещё немного титров для полного понимания, но и на этом благодарю 🤝

  • @olehkarpiv8705
    @olehkarpiv8705 Рік тому +4

    I had the same problem p20e8 00 . First of check your a main battery on your car, if it to older (4-6 years) you should install new battery. After replacing a battery and a few kilometres lamp “urea and service” disappeared.

    • @Fla38600
      @Fla38600 11 місяців тому +1

      Hello, are you sure about this ? How do you explain the link with pressure too low in error message ?

    • @davebeeton97
      @davebeeton97 7 місяців тому

      8 months after you wrote this , how is the system now ?? Thanks

  • @mondodaftasabrush
    @mondodaftasabrush Рік тому +5

    Many thanks for uploading this... I assume from your tests and the way the pump solenoid and level float operate even the heater that you deemed this unit serviceable and another fault was found ?
    I was looking for a nox flow test measurement

  • @mykytot
    @mykytot 5 місяців тому

    Great job gentleman, manny thanks. On my Crossland X I connected pump with plus on top and minus down and the pump is turning revers I think because blow in tank not suck. Strange. On car don't have pressure.

    • @MikeBetynaVANS
      @MikeBetynaVANS  5 місяців тому

      I'm not familiar with this model but it sounds like youve got polarity reversed. Simply swap your wires around. DC motors are usually bipolar(work both ways). Most of adblue systems are pumping fluid back into the tank to drain any fluid left in the lines to prevent freezing when you switch your engine off. You may have 2 pumps. One that pressurises lines and one that drains them.

  • @robyzr7421
    @robyzr7421 Рік тому +1

    Hello, thx x sharing your interesting videos about Ad Blue tank and its electronic board. Your purpose was looking a bug or break in the system x repair or just curiosity to realize how it works..

  • @DiyMech
    @DiyMech Місяць тому

    The over complication in all this just for a pump is horrendous, and here we are trying to save the planet, everyhting is over emgineered to the nth with of course the extra cost involved, not forgetting the adblue cost manufacture distribution etc......

  • @erhanerhann3085
    @erhanerhann3085 Рік тому +3

    Thank You

  • @MrLukas2411
    @MrLukas2411 11 місяців тому +1

    thanks for posting this video

  • @ihorpol8431
    @ihorpol8431 Рік тому +2

    Thank you so much.

  • @djimicarton8283
    @djimicarton8283 21 годину тому

    A la minute 5h18 le test du connecteur rouge aurait dû se faire sur la carte et pas sur la fiche possible problème oxydation des pin du connecteur rouge ou defot de la fiche

  • @morganmtu4525
    @morganmtu4525 Рік тому +3

    Peugeot fait des erreurs de recherche et développement produit ... Ou alors ils sont seulement cupides ??? Dîtes moi si vous avez une prise en charge à 100% sans avoir à demander ??? Je n'ai aucune confiance en ce fabricant...

  • @Fla38600
    @Fla38600 11 місяців тому +1

    I had the same error message than you: "P20E Pressure of the urea fluid : Urea Pressure Too Low fault".
    Today I have tried to replace module with pump, solenoid... but I kept the old electronic board.
    I have reset defaults and made 30km without error message.
    I suspect the pressure sensor or the pressure valve to be broken-down.
    On default message, pressure was 4 bars and 6,656 bars on a second message.
    I will check the pressure on new module that seems to work properly and give you information.
    Anyone know what is expected pressure ?

    • @MrLukas2411
      @MrLukas2411 11 місяців тому +3

      4 bar is minimum sender value, that is why it gives 4 bar, but there is no pressure at all. Minumum should be around 6.5 bar. I think that Driver mosfets for the pump start to be deffective and thats is why pump fails to operate. I have replaced my AD blue tank , took old one with me...and investigated all components, solenoids, heaters, pressure sensors...all working fine. Just these mosfets were suspicious so i have replaced all four of them. Tank works again with no problem.

    • @Fla38600
      @Fla38600 11 місяців тому +1

      @@MrLukas2411 good work !!
      In my case, in have cheched, Mosfets seems to be good.
      I keep you informed if I find something interresting.

    • @Fla38600
      @Fla38600 11 місяців тому +2

      ​@@MrLukas2411For my information, how did you identify that Mosfets were in defect ? Did you made some measurements ? Or it was an hypothesis ?

    • @MrLukas2411
      @MrLukas2411 11 місяців тому +5

      @@Fla38600 There are 4 square mosfets under pressure accumulator that i found . two of them were defective, just shorted. Another problem with the tank is that it is a system of many sensors and heaters as well as electronics....If one of sensors or heaters becomes defective, Whole tank will go offline and there is Your message...urea pressure too low. So as well, there can be a problem in a heater or pressure sensor. During tank boot after starting engine, tank system verifies all components so if one of them is not responding, tank goes to off line mode. Mine was 95% mosfet problem cause i have measured all senders and heaters and they were ok in values...check them per specification. So....what else to say than GOOD LUCK!!!

    • @hvtvalencia36
      @hvtvalencia36 8 місяців тому +1

      5,5 bar

  • @danielhuether611
    @danielhuether611 Місяць тому

    Does anyone can help me where to put the 12v on to let the pump run? Want to connect it to a battery to clean the pump itself... was quite hard to figure it out with the video. But anyway, awesome video!

  • @etztz123
    @etztz123 Рік тому +2

    Thanks for the Vid, I guess your not fixing as you wouldn't of cut tank up lol

  • @Fla38600
    @Fla38600 11 місяців тому

    Thanks a lot. Nice video.
    Do you know the resistor value of temp sensors @25°C for exemple ?
    On mine I have measured :
    10 kOhms between two yellow wires (heating resistor temp sensor).
    3 kOhms between two blue wires (liquid temp sensor).
    My car is a Peugeot Parter tepee (B9) Phase 2 1.6 Blue HDi FAP S&S 120 cv

    • @EnduroCordoba
      @EnduroCordoba 2 місяці тому

      los cables azules tienen que darte 3,3 KOhms y los amarillos 10 Kohms , a mi me dana 300 Ohms y le puse una resistencia de 10Kohms para simular 25º C y anular este termistor.

  • @alinzmeul
    @alinzmeul 20 днів тому

    Does anyone know if there is supposed to be fluid inside this side of the tank? I opened mine, and it was about 1/4 full with Adblue. Thanks.

    • @MikeBetynaVANS
      @MikeBetynaVANS  12 днів тому

      It should be dry in there. That indicates pump itself leaking. It will eventually flood the circuit board and mess it up.

    • @alinzmeul
      @alinzmeul 12 днів тому +1

      ​@@MikeBetynaVANSThank you. You are correct. The pump no longer comunicates with the ECU.

  • @TheMcblan
    @TheMcblan Рік тому +4

    Hi you need to talk on vedio to understand what you did

  • @jyvais1001
    @jyvais1001 Рік тому +1

    vidéo qui ne sert a rien pas de commentaire

  • @dragannatricevic6634
    @dragannatricevic6634 9 місяців тому

    Iskljuci smece u eku 2500 e kosta to sranje ...