+Rodrigo Adolfo You are correct (and I do state as such in the video); when I made this video, I was a bit pressed for time and made do with what I had. One of these days, I'll go back and rerecord it and introduce a new series of mistakes :) .
***** practically there is no such type of loading in the real environment. for example if you take compression and flexural strength testing for concrete, you can find the type of loading in the actual structure. so that you can use the result for decision purpose. to me the test is neither tension nor compression. to assume it is tension test the whole part(body) of the concrete should be in tension force. as you see here the force is applied in a line wise.
can someone tell me the practical use of this test and significance in real world? how do this differ from pure tension? please answer. need for research. thank you!
Love this guy’s videos
can you tell us the basic concept of this test while we are applying compression load to find tensile strength please?
@I know Cause I'm BatMan. exactly this happens due to poisson effect.
We are applying compression in the vertical direction but the cylinder will undergo tension along the length.
nice shorts
Hi matt Oreilly,
What is the rate of loading of split tensile test...?
100 to 200 psi/min [0.7 to 1.4 MPa/min]
can i test the compressive machine? what type of instrument need the test please
According to ASTM you are supposed to average two measurements of length.
Could you tell me your specimen height and dia. As far as i know i heard the dia probably 6 inch but i didn't know the height so tell me ?
12 inch, most likely for a 2:1 ratio
What is ur mix proportion for the cylinder?
Rate seemed too fast
I have done this test after treating the concrete with different conditions to see which treatment improves the concrete.
what was the result sir? in numbers.
the wood fringe ought be longer or equal to the cylinder.
+Rodrigo Adolfo You are correct (and I do state as such in the video); when I made this video, I was a bit pressed for time and made do with what I had. One of these days, I'll go back and rerecord it and introduce a new series of mistakes :) .
I appreciate.
Can we do the split test using 4x8 cylinder???
Yes, unless your aggregate size is larger than allowed for a 4x8.
cylinder size should be 3 times the aggregate size
can I test the compressive machine beside would instrument name of the test
i also want to know if compressive machine can be use
thanx alot
is this the same as shear test?
what is the practical use of this test?
***** practically there is no such type of loading in the real environment. for example if you take compression and flexural strength testing for concrete, you can find the type of loading in the actual structure. so that you can use the result for decision purpose. to me the test is neither tension nor compression. to assume it is tension test the whole part(body) of the concrete should be in tension force. as you see here the force is applied in a line wise.
Maniac
Buddy carefully your finger stock in there
Your name reminds me of maddy o reilly
can someone tell me the practical use of this test and significance in real world? how do this differ from pure tension? please answer. need for research. thank you!
The test is an indirect way of determining the tensile strength of concrete since direct methods are somewhat difficult.
could i ask at what rate was the load applied?
+Baldeep Bhullar The ASTM calls for 100 to 200 psi/min, which works out to a load of about 150-300 lb/second.
+Matt OReilly Thank you for your prompt response Matt. Cheers!