How to add/configure/test analog input module of PLC S7-300 SM 331-7KF02-0AB0 by using Simatic V5.6

Поділитися
Вставка
  • Опубліковано 19 вер 2024

КОМЕНТАРІ • 38

  • @immadhussain4319
    @immadhussain4319 2 роки тому

    4 wire configuration not found in your vedios

  • @bahaagamal4995
    @bahaagamal4995 3 роки тому +1

    Thank you very much for this video , all your videos are very valuable.

  • @reybisdak9488
    @reybisdak9488 3 роки тому +1

    Excellent video Sir.i believe this is a complete tutorials hehe.

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому +1

      Dear sir,
      For PC we used other software like Modicon... or some software that can link with PLC S7-300.
      Thanks

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому +1

      My pleasure!

    • @mehdibessaad3388
      @mehdibessaad3388 3 роки тому +1

      Why the led sf is on?? Do you have any problem??

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      @@mehdibessaad3388 Dear sir,
      Because some configuration of channel not correct sir like selection hardware to voltage but configuration amp it will has some fault.
      But we can use it for other channels that we make correct configuration.
      Thanks!

    • @reybisdak9488
      @reybisdak9488 3 роки тому

      Input analog sir you used potentiometer sir to adjust 4 to 20ma.hehe pls show in the camera Sir.thank you Sir.

  • @reybisdak9488
    @reybisdak9488 3 роки тому +1

    Thank you for Response Sir.

  • @gabrieldamore1307
    @gabrieldamore1307 Рік тому +1

    I have a problem: I set the range from 0 to 100% for example, Why when I do the test if I put 0 as a value It gives me 3.5 mA and if I put 100 It gives me 17.5 mA on the tester. The only difference with your settings, Is that i set 2 wire configuration and not 4 wire.

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  Рік тому

      Dear sir,
      First please check the configuration of hardware such as connections, power supply 24VDC?
      Second please check the scale setting of 2 wire and 4 wire of scaling block and test again.
      Thanks

  • @devincortez9312
    @devincortez9312 Рік тому +1

    None of the lights are changing on your analog input module, how do you get them to show up?

  • @sinanartemis6176
    @sinanartemis6176 2 роки тому +1

    hello sir,
    thanks foe tour great videos
    ı have the same analog module
    ı had a temperature transmitter 2 wire 4-20ma output
    ı set everyting the same with you
    and ı wired m+ to my transmitter positive and m- to my transmitter negative ı saw 32767 value or -32767 İ am not sure what is the problem.
    ı saw when ı put a multimeter between analog card ma- pin and transmitter- pin ı saw 6ma value
    what is the problem what is my mistake

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  2 роки тому +1

      Dear sir,
      Thanks, please check your selection between hardware and software for setting.
      What software that you use? TIA Portal or Simatic Manager?

    • @sinanartemis6176
      @sinanartemis6176 2 роки тому

      @@generaltechnologyknowledge5165 ı use simatic manager ı selected 2 wire configuration on software as you showed

  • @suriyat8773
    @suriyat8773 2 роки тому

    How to absulte Encoder thank you

  • @somnathwaghmare51
    @somnathwaghmare51 3 роки тому +1

    Same analog configuration and it's used two wire thermocouple sensor at each 8 channel
    I'm facing SF singnal even having 24v supply at pin 1 and 20
    Please is their anything else to check

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      Dear sir,
      Please check software configuration on each channel must be the same as hardware selection.
      Thanks

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      Anyway I will create more video about how to connect Thermocouple with two wire connection for you.
      Thanks

    • @somnathwaghmare51
      @somnathwaghmare51 3 роки тому

      @@generaltechnologyknowledge5165 thanks for reply sir
      Actually it's running system for long time and suddenly all 3 AI module has SF fault and online diagnostic module status is ok

    • @somnathwaghmare51
      @somnathwaghmare51 3 роки тому +1

      @@generaltechnologyknowledge5165 it's always appreciated efforts to guide us thank I hope it's will helpful to

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      @@somnathwaghmare51 My pleasure!

  • @sujitkumarsantra5996
    @sujitkumarsantra5996 3 роки тому +1

    Can i replace an AI module for a Running system? If I want to replace an AI module with a same new module in an Running system then what to do?

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      Dear sir,
      We cannot do it with running system.
      Please do it with stop system. Because it will effect to other modules or other machines during running. I'm not recommend to replace during running system.
      Safety first!
      Thanks you!

    • @sujitkumarsantra5996
      @sujitkumarsantra5996 3 роки тому +1

      @@generaltechnologyknowledge5165 it's ok,But if I do then what types of problem can be occurred?;and what types of fault can be create?

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      @@sujitkumarsantra5996 Sorry sir,
      Please detail the problems! what is the fault?
      Thanks you!

  • @ramcom8113
    @ramcom8113 2 роки тому +1

    Hello. Do somebody want to buy 6ES7331-7TF01-0AB0?