Sir
Kiya compressor speed ky sat out door fan motor ke speed be kam ya ziada hoti hy .room temperature sensor ky hisab sy....ya condenser ky end ma ju sensor laga hy os hisab sy out door fan motor ki speed kam ya ziyada hoti hy
Fan motor ka speed condenser ke end me lage huwe sensor se increase awr decrease hota hai
Sir sensor markit se leke koyi bhi laga sakte hai mach ho jaye ga
Agar hum r290 charge Karna chahain r134a ka system main to koe problem hogi .... ?
Yes Dear, problem hogi kyunki both refrigerants ke properties different hain
Assalamualaikum Sir,
Which AC is more efficient ( higher COP) in a perticular operating indoor & out door temperature.
Does, really Inverter AC save energy for a specified room temperature, compared to Non Inverter AC?
Would be helpful for us, if u can make a detailed contents on that purpose, afterwards.
Wa Alaikumussalam,
I think now a days Gree are very good in efficiency,
Yes inverter can save 20% cost as compared to non inverter ACs
@FKmechofficial but how is it technically possible. Logically with P-h diagram, if you could demonstrate us, would be beneficial for us.
Seems to me, Inverter AC most of the time running in part load and normally, any machine running in partload efficiency is less, compared to full load. Whereas, Non Inverter AC is running, either Full load or remain off.
Whereas, Inverter Circuit itself consumes 3 to 5 % more input energy than out put.
There would be some possibility to save energy for Inverter AC by controlling Refrigerent flow based on outside ambient conditions, which non Inverter AC can't do.., but I am not sure.
Hope, u can explain it to us and we will be grateful for that. No one have seen to explain it in the U- tube channel technically with valid reasons.
Thanks for all your technical support.
Nice video Sir r22 ka discharge temp Kitna huta hy
Isss video me total detail hai. 👇
ua-cam.com/video/N_KE-H8SZv0/v-deo.html
Nice very good
Sir want to charge r290a gas in 134a gas compressor because I need evaporator temperature +5/+10 degree celsius
I need a cooling system whose compressor will be 90 watt and gas will be 600/290 evaporator temperature will be +5/+10 degree celsius.
Please help me ???
Dear Brother,
If you want +5⁰C or +10⁰C evap temp:, then you will have a small cycle for maintaining this temp:
This is not applicable to have good result if you charge R290 in R134a's same cycle
Very nice video and informative video..
Shukarya Sir ❤️