КОМЕНТАРІ • 23

  • @trozanhorse7532
    @trozanhorse7532 14 днів тому +1

    In KWU 500MW unit,
    If any of Running TDBFP hand tripped form DCS pannel,
    MDBFP will START in Auto Or not?
    (MDBFP is in standby mode)

  • @qolisfandrairawan2130
    @qolisfandrairawan2130 3 місяці тому +1

    Sir, why the pump speed is higher than motor speed ? By using hydraulic coupling, the output speed must lower than motor speed, isn't ?

    • @kpatelbla
      @kpatelbla  3 місяці тому

      Actually Motor input power must be higher than pump output, but RPM can be increased by hydraulic coupling, no issue. Suppose Motor input power 12 MWH so pump mechanical output cannot exceed 12 MWH.

  • @johnashok9822
    @johnashok9822 День тому +1

    Dear sir please make on governing system full process and how governer work like giving 600 MW to 500 mw etc

    • @kpatelbla
      @kpatelbla  День тому

      It is very interesting topic, I will make it in simplest way of explanation.

    • @johnashok9822
      @johnashok9822 День тому

      @@kpatelbla thanks 🙏🙏 you sir waiting for the video

  • @0503manoj
    @0503manoj 3 місяці тому +1

    Sir
    Before starting of MDBFP reheater Attempretion valve and super heater Attempretion valve always should have open or not...?

    • @kpatelbla
      @kpatelbla  3 місяці тому

      It can be made open but block valve of both attemperator must be closed.

  • @user-wm5ti1od6r
    @user-wm5ti1od6r 6 місяців тому +1

    Good explanation. Please explain Operation of hydraulic coupling. Scoop function and Remote trip solenoid

    • @kpatelbla
      @kpatelbla  6 місяців тому

      You can watch ' How scoop tube function' video ua-cam.com/video/WILqwqeLd9E/v-deo.htmlsi=C8mw2HscAzPMFJdq

    • @kpatelbla
      @kpatelbla  6 місяців тому

      Remote trip solenoid & Rapid start, I will explain.........

  • @pankajkumarpatel5664
    @pankajkumarpatel5664 6 місяців тому +2

    Sir boostor pump suction me buket stainer or main pump me conical stainer hota hai or sir boostor pump ka suction pr 8 kg tak hota hai

    • @kpatelbla
      @kpatelbla  6 місяців тому

      Yes you are correct, but suction pressure varies according to Deaerator pr

  • @chandreshpatel6380
    @chandreshpatel6380 6 місяців тому +1

    Sir need video on bearing stiffness or shaft stiffness

  • @devivara1162
    @devivara1162 6 місяців тому +1

    Sir what is water hammer??? any 3 reasons why this water hammer forms??

    • @kpatelbla
      @kpatelbla  6 місяців тому

      When steam comes in contact of condensate water it moves with high velocity of steam and create hammering sound on pipe surface, before it get condense.

  • @motive0507
    @motive0507 6 місяців тому +1

    ECW water is going to mechanical seal cooling and also to seal jacket. What is seal jacket. Please differentiate mechanical seal and seal jacket

    • @kpatelbla
      @kpatelbla  6 місяців тому

      Mechanical seal water goes to mechanical seal cooler instead of directly to mechanical seal. Jacket cooling provided at pump jacket.

    • @motive0507
      @motive0507 6 місяців тому +1

      @@kpatelbla could you please physically differentiate seal jacket and mechanical seal

    • @motive0507
      @motive0507 6 місяців тому

      Please give reply

  • @devivara1162
    @devivara1162 6 місяців тому

    Sir why balancing line is provided before pump in Condensate extraction pump??in power plant???

    • @kpatelbla
      @kpatelbla  6 місяців тому

      The only purpose of balancing line is to prevent the shifting of Rotor of the pump during operation.