Rapid Chloride Permeability Test - Experimental Demo (English)

Поділитися
Вставка
  • Опубліковано 4 гру 2024

КОМЕНТАРІ • 25

  • @deebasankaran5919
    @deebasankaran5919 3 роки тому +1

    Well done...neatly explained

  • @julianp-vwv
    @julianp-vwv Рік тому +1

    Summary)
    materials)
    1. sodium chloriden solution
    2. NaOH solution
    desicattor)
    this is desicatror set, so using this will be concrete specimens filling, with distilled water, pump inject water in concrete complex
    concrete specimens are completely being submerged in water
    this indicates that all of concrete specimens completely vacuum
    take specimens out
    no spaces, completely closed, fill the cell with a electronic(NaOH, NaCl)
    put sensors and set 60V for 6 hours.

  • @veedu2.o219
    @veedu2.o219 4 роки тому +1

    Every civil engineer must know

  • @k.thangapandi4643
    @k.thangapandi4643 4 роки тому +1

    Very nice and useful information

  • @ponmalarasokan8337
    @ponmalarasokan8337 2 роки тому

    In ASTM 1202 it is said fill the voids in sample with CaOH

  • @selvaperumal5073
    @selvaperumal5073 4 роки тому +1

    Super

  • @abhishekprakash5806
    @abhishekprakash5806 2 роки тому +1

    how about of using column size of 150x300 mm^2 ?

    • @ramsworldofwisdom2177
      @ramsworldofwisdom2177  2 роки тому

      Sir you have to core cut the sample for testing from your specimen (column)

  • @ponmalarasokan8337
    @ponmalarasokan8337 2 роки тому +2

    why should we prepare sample in vacuum desigator??

    • @ramsworldofwisdom2177
      @ramsworldofwisdom2177  2 роки тому

      Vaccum desigator is used to remove air voids without any additional agents

  • @ponmalarasokan8337
    @ponmalarasokan8337 2 роки тому

    in one video it is said to prepare sample by lime saturation process

  • @akileshs4358
    @akileshs4358 8 місяців тому

    Sir,how many hours should be kept in vacuum designator????

  • @misseffah80
    @misseffah80 3 роки тому +1

    Is this a process of AASHTO T277?

    • @ramsworldofwisdom2177
      @ramsworldofwisdom2177  3 роки тому +1

      Procedure is same for both ASTM C1202 and AASHTO T277... Only the limitations in result variations are different...

  • @arnolddadios7042
    @arnolddadios7042 2 роки тому +1

    What is your school name and place?

  • @ponmalarasokan8337
    @ponmalarasokan8337 2 роки тому

    what if we do the test without vacuuming it

  • @pratipalvasava4325
    @pratipalvasava4325 3 роки тому

    M45 grade ka average rcpt result koi bata sakata h..??

    • @ramsworldofwisdom2177
      @ramsworldofwisdom2177  3 роки тому

      RCPT values differ for each mix of concrete... we cannot derive a standard value of RCPT for certain concrete grades...